XPPOWER AMM90PS05

AC-DC
90 Watts
xppower.com
AMM90 Series
•
CEC2008 & EISA2007 Compliant ≥12V
•
Worldwide Medical Approvals
•
Small Size/High Power Density
•
Class I and Class II Versions
•
Operating Temperature up to +60 °C
•
High Efficiency
•
Locking Output Connector ≥15 V
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 1.2 A rms at 115 VAC,
0.6 A rms at 230 VAC
Inrush Current
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
• 0.98 typical
Earth Leakage Current • 90 µA max at 115 VAC/60 Hz,
(Class I Versions)
150 µA max at 230 VAC/50 Hz
Input Protection
• Internal 2.5 A fuse in live & neutral lines
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
5 to 48 VDC
Not user-adjustable
±2 %
No minimum load required
2 s max at 115 VAC
<80 ms at 115 VAC
15 ms minimum at full load & 115 VAC
0.5% maximum
See table
4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 112-140% Vnom, recycle input to reset
Overtemperature
• Unit shuts down, auto recovery
Protection
Overload Protection
• 110-200%, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
• 0.04%/°C
Coefficient
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 78% min for 5 V, 6 V & 9 V models
85% minimum for all others
• 4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
• 50-110 kHz variable
• 3.4 W/In3
• 150 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Cooling
• Convection-cooled
Operating Humidity
• 10-95% RH, non-condensing
Storage Temperature
• -20 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55011/FCC/VCCI, Class B conducted
EN55011/FCC/VCCI, Class B radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
• EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B (Perf Criteria A, A, B
with 70% load)
• EN60601-1, UL60601-1,
CSA22.2 No. 601-1 per cUL, CE Mark
Output
Power
60 W
60 W
70 W
80 W
85 W
85 W
90 W
90 W
90 W
90 W
90 W
Output
Voltage
5.0 V
6.0 V
9.0 V
12.0 V
13.5 V
15.0 V
18.0 V
19.0 V
24.0 V
30.0 V
48.0 V
Total
Regulation(2)
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
Output
Current
12.00 A
10.00 A
7.78 A
6.67 A
6.30 A
5.67 A
5.00 A
4.74 A
3.75 A
3.00 A
1.87 A
Model
Number(3, 4)
AMM90PS05
AMM90PS06
AMM90PS09
AMM90PS12
AMM90PS13
AMM90PS15
AMM90PS18
AMM90PS19
AMM90PS24
AMM90PS30
AMM90PS48
Notes
1.
2.
3.
4.
Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point.
Total regulation includes initial set accuracy, line and load regulation.
For class II versions, add ‘C2’ to model number e.g. AMM90PS24C2.
For optional Barrel Jack Connector, add ‘B1’ to model number e.g. AMM90PS24C2B1 (not available on 5 V or 6 V models).
Mechanical Details
Cable length approx 48” (1219mm)
1.72
(43.7)
Rubber foot
(4 places.)
1
2
PIN CONNECTIONS
PS09 - PS48
Pin
Function
1
Return
2
Output+
3
Return
4
Output+
3
4
5.12
(130.0)
3
5
2
1
3.00 (76.2)
Optional Barrel Jack Connector
0.083 (2.1)
0.217
(5.5)
0.413
(10.5)
0.02
(0.5)
0.433 (11.0)
4
PIN CONNECTIONS
PS05 - PS06
Pin
Function
1
Return
2
Return
3
Output+
4
Return
5
Output+
AC Input
IEC 320-C14 Inlet - For Class I version
IEC 320-C18 Inlet - For Class II version
Notes
1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length.
2. Maximum load per pin on output connector is 7.5 A.
3. Output connector for AMM90PS05 and PS06 is 5 pin 180° DIN.
4. Output connector for AMM90PS09-PS13 is KYCON KPP-4P non locking type. For mating half, use KYCON KPJ-4S-S or equivalent.
5. Output connector for AMM90PS15-PS48 is KYCON KPP-4P locking type. For mating half, use KYCON KPJ-4S-S or equivalent.
6. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input.
7. Weight: 1.46 lb (660 g).
15-Dec-08
AC-DC
AMM90
Models and Ratings