MAXIM MAX6621AUB+

19-0729; Rev 1; 9/07
PECI-to-I2C Translator
Features
♦ 400kbps I2C-Compatible, 2-Wire Serial Interface
The MAX6621 PECI-to-I2C translator provides an efficient, low-cost solution for PECI-to-SMBusTM/I2C proto-
♦
♦
♦
♦
♦
col conversion. The PECI-compliant host reads
temperature data directly from up to four PECI-enabled
CPUs. Interrupts are generated when the measured
temperature exceeds the high-temperature limit and
causes ALERT to assert. The RESET input allows the
host to reset the I2C bus in the event of a communication error.
♦
♦
♦
The I2C interface provides an independent serial communication channel to communicate synchronously with
peripheral devices in a multiple master or multiple slave
system. This interface allows a maximum serial-data
rate of 400kbps.
♦
♦
The MAX6621 is designed to operate from a +3.0V to
+3.6V supply voltage and ambient temperature range
of -20°C to +120°C.
+3V to +3.6V Supply Voltage
PECI-Compliant Port
PECI-to-I2C Translation
ALERT Output
RESET Input (May Be Disabled as a Factory
Option)
Programmable Temperature Offsets
-20°C to +120°C Operating Temperature Range
VREF Input Refers Logic Levels to the PECI
Supply Voltage
Automatic I2C Bus Lockup Timeout Reset
Lead-Free, 10-Pin µMAX® Package
Ordering Information
Applications
Servers
PART
Workstations
Desktop Computers
TEMP RANGE
PIN-PACKAGE
MAX6621AUB+
-20°C to +120°C
10 µMAX
MAX6621AUB+T
-20°C to +120°C
10 µMAX
T = Tape-and-reel package.
+Denotes a lead-free package.
SMBus is a trademark of Intel Corp.
Pin Configuration appears at end of data sheet.
µMAX is a registered trademark of Maxim Integrated Products, Inc.
Typical Application Circuit
+3.3V
VCPU
VTT
VCC
SDA
I2C
SCL
SDA
VREF
SCL
PECI
MASTER
RESET
MAX6621
CPU
INTERNAL
TEMP
SENSOR
ALERT
AD0
GND
________________________________________________________________ Maxim Integrated Products
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
1
MAX6621
General Description
MAX6621
PECI-to-I2C Translator
ABSOLUTE MAXIMUM RATINGS
(All voltages with respect to GND.)
VCC ..........................................................................-0.3V to +4V
AD0, RESET, ALERT...................................-0.3V to (VCC + 0.3V)
SCL, SDA .................................................................-0.3V to +6V
VREF .........................................................................-0.3V to +4V
PECI .........................................................-0.3V to (VREF + 0.3V)
DC Current through SDA ...................................................10mA
Continuous Power Dissipation (TA = +70°C)
10-Pin µMAX (derate 5.6mW/°C over TA = +70°C)......444mW
Operating Temperature Range .........................-20°C to +120°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(Typical Application Circuit, VCC = +3V to +3.6V, VREF = +0.95V to +1.26V, TA = -20°C to +120°C, unless otherwise noted. Typical
values are at VCC = +3.3V, VREF = +1.0V, TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
SUPPLY
Operating Supply Voltage
VCC
Operating Supply Current
ICC
Power-On-Reset Voltage
VPOR
3.0
SCL = 400kHz
4
2.60
3.6
V
7
mA
2.95
V
0.3
x VCC
V
5.5
V
INPUT SCL, INPUT/OUTPUT SDA
Low-Level Input Voltage
VIL
High-Level Input Voltage
VIH
Low-Level Output Voltage
VOL
Leakage Current
IL
Input Capacitance
CI
0.7
x VCC
IOL = 6mA
-1
0.4
V
+1
µA
10
pF
ALERT
Low-Level Output Voltage
VOL
IOL = 6mA
0.4
V
0.3
x VCC
V
ADDRESS INPUT AD0/RST
Low-Level Input Voltage
VIL
High-Level Input Voltage
VIH
0.7
x VCC
VCC
+ 0.3
V
Leakage Current
IL
-2
+2
µA
Input Capacitance
CI
10
pF
PECI
Supply Voltage to PECI Cell
VREF
0.95
1.26
V
Input Voltage Range
VIN
-0.3
VREF
+ 0.3
V
Low-Level Input Voltage
Threshold
VIL
0.275
x VREF
0.500
x VREF
V
High-Level Input Voltage
Threshold
VIH
0.550
x VREF
0.725
x VREF
V
2
_______________________________________________________________________________________
PECI-to-I2C Translator
(Typical Application Circuit, VCC = +3V to +3.6V, VREF = +0.95V to +1.26V, TA = -20°C to +120°C, unless otherwise noted. Typical
values are at VCC = +3.3V, VREF = +1.0V, TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
VH
0.1
x VREF
Low-Level Sinking Current
IIL
0.5
High-Level Sourcing Current
IIH
-6
Input Capacitance
CI
(Note 2)
Signal-Noise Immunity Above
300MHz
VN
(Note 2)
Hysteresis
TYP
MAX
UNITS
V
1.0
mA
mA
10
0.1
x VREF
pF
VP-P
TIMING CHARACTERISTICS
(Typical Application Circuit, VCC = +3V to +3.6V, VREF = +0.95V to +1.26V, TA = -20°C to +120°C, unless otherwise noted. Typical
values are at VCC = +3.3V, VREF = +1.0V, TA = +25°C.) (Note 2)
PARAMETER
RESET Pulse Width
SYMBOL
CONDITIONS
RST
MIN
TYP
MAX
100
UNITS
ns
I2C INTERFACE
Serial-Clock Frequency
fSCL
400
Bus Free Time Between a
STOP and a START Condition
tBUF
1.3
µs
Hold Time, (Repeated) START
Condition
tHD, STA
0.6
µs
Repeated START Condition
Setup Time
tSU, STA
0.6
µs
STOP Condition Setup Time
tSU, STO
0.6
µs
Data Hold Time
tHD, DAT
Data Setup Time
tSU, DAT
120
ns
SCL Clock-Low Period
tLOW
1.3
µs
SCL Clock-High Period
tHIGH
0.6
µs
(Note 3)
0.9
kHz
µs
Rise Time of Both SDA and
SCL Signals, Receiving
tR
(Notes 4, 5)
20
+ 0.1Cb
300
ns
Fall Time of Both SDA and
SCL Signals, Receiving
tF
(Notes 4, 5)
20
+ 0.1Cb
300
ns
tF.TX
(Notes 4, 5)
20
+ 0.1Cb
250
ns
Fall Time of SDA Transmitting
Pulse Width of Spike
Suppressed
tSP
(Note 6)
Capacitive Load for Each
Bus Line
Cb
(Note 4)
50
160
ns
400
pF
PECI INTERFACE
Bit Time (Note 7)
tBIT
Overall time evident on PECI
0.495
500
Driven by MAX6621
0.495
250
µs
_______________________________________________________________________________________
3
MAX6621
ELECTRICAL CHARACTERISTICS (continued)
MAX6621
PECI-to-I2C Translator
TIMING CHARACTERISTICS (continued)
(Typical Application Circuit, VCC = +3V to +3.6V, VREF = +0.95V to +1.26V, TA = -20°C to +120°C, unless otherwise noted. Typical
values are at VCC = +3.3V, VREF = +1.0V, TA = +25°C.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Bit Time Jitter
tBIT, jitter
Between adjacent bits in an PECI message
header or data bytes after timing has been
negotiated
1
%
Change in Bit Time
tBIT, drift
Across a PECI address or PECI message
bits as driven by MAX6621
2
%
High-Level Time for Logic-High
tH1
0.6
0.75
0.8
x tBIT
High-Level Time for Logic-Low
tH0
(Note 8)
0.2
0.3
0.4
x tBIT
Client Asserts PECI High
During Logic-High
tSU
0
0.2
x tBIT-M
Rise Time
tR
Measured from VOL to VPMAX,
VREF(nom) -5% (Note 9)
30 +
5/Node
ns
Fall Time
tF
Measured from VOH to VNMAX,
VREF(nom) +5% (Note 9)
30/Node
ns
Hold Time
tHOLD
Time for client to maintain a low idle drive
after MAX6621 begins a message (Note 10)
0.5
x tBIT-1
Stop Time
tSTOP
A constant low level driven by MAX6621
(Notes 8, 11)
Maximum Dwell Time of the
PECI Client
tRESET
From the end of a ResetDevice command
to the next message to which the reset
client must be able to respond
Minimum PECI Low Time
Preceding a Message
tSETUP
If the prior tBIT is not known by MAX6621,
the maximum tBIT must be assumed and
tSETUP = 1ms in this case (Note 12)
2
x tBIT-M
0.4
2
ms
x tBIT-X
Note 1: All parameters are tested at TA = +25°C. Specifications over temperature are guaranteed by design.
Note 2: Guaranteed by design; not production tested.
Note 3: A master device must provide a hold time of at least 300ns for the SDA signal (referred to VIL of the SCL signal) to bridge
the undefined region of SCL’s falling edge.
Note 4: Cb = total capacitance of one bus line in pF. tR and tF measured between 0.3 x VCC and 0.7 x VCC.
Note 5: ISINK ≤ 6mA. Cb = total capacitance of one bus line in pF. tR and tF measured between 0.3 x VCC and 0.7 x VCC.
Note 6: Input filters on the SDA and SCL inputs suppress noise spikes less than 50ns.
Note 7: The MAX6621 must drive a more restrictive time to allow for quantized sampling errors by a client yet still attain the minimum time less than 500µs. tBIT limits apply equally to tBIT-A and tBIT-M.
Note 8: The minimum and maximum bit times are relative to tBIT defined in the timing negotiation pulse.
Note 9: Extended trace lengths can appear as additional nodes.
Note 10: The client may deassert its low idle drive prior to the falling edge of the first bit of the message by using the rising edge to
detect a message start. However, the time delay must be sufficient to qualify the rising edge as a true message rather than
a noise spike.
Note 11: The message stop is defined by two consecutive periods when the bus has no rising edge. Tolerance around this time is
based on the tBIT-M error budget.
Note 12: tSETUP is not additive with tSTOP. Rather, these times may overlap.
4
_______________________________________________________________________________________
PECI-to-I2C Translator
PIN
NAME
1
PECI
FUNCTION
2
AGND
3
AD0
I2C Bus Device Address Selection Input
4
SDA
I2C Bus Data Input/Output
5
SCL
I2C Bus Clock Input/Output
6
VCC
Power Supply. Bypass to GND with a 0.1µF capacitor.
7
GND
Power-Supply Ground
8
RESET
I2C Reset Input. Pull RESET low to reset I2C interface and default all registers to startup values.
Drive high for normal operation.
9
ALERT
ALERT Interrupt Open-Drain Output. Asserts low when any temperature exceeds the
programmed limit.
10
VREF
Platform Environment Control Interface (PECI) Serial-Bus Input/Output
Analog Ground
PECI Input Supply Voltage. Bypass VREF to AGND with a 0.1µF capacitor.
Block Diagram
MAX6621
SDA
I2C
PORT
SCL
PECI
TRANSLATION
ENGINE
AD0
PECI
PORT
VREF
RESET
ALERT
PECI
_______________________________________________________________________________________
5
MAX6621
Pin Description
MAX6621
PECI-to-I2C Translator
Detailed Description
The MAX6621 obtains temperature data from an internal temperature sensor in PECI-compliant hosts. Up to
four PECI hosts can be connected to the PECI I/O interface. The MAX6621 handles all the PECI transmissions
ADDRESS
and uses a 2-wire, I2C-compatible serial interface to
communicate with the PECI host.
Registers and Commands
The following is an overview of the I2C/SMBus registers/commands supported by the MAX6621.
DESCRIPTION
TRANSACTION TYPE
00h
Read socket 0, domain 0 temperature register
ReadWord
01h
Read socket 0, domain 1 temperature register
ReadWord
02h
Read socket 1, domain 0 temperature register
ReadWord
03h
Read socket 1, domain 1 temperature register
ReadWord
04h
Read socket 2, domain 0 temperature register
ReadWord
05h
Read socket 2, domain 1 temperature register
ReadWord
06h
Read socket 3, domain 0 temperature register
ReadWord
07h
Read socket 3, domain 1 temperature register
ReadWord
08h
Read maximum temperature for all enabled sockets/domains register
ReadWord
09h
Read firmware version register
ReadWord
0Ah
Read maximum temperature address
ReadWord
0Bh
Read socket and domain that caused alert
0Ch
Read/write CONFIG0 register
ReadWord
ReadWord/WriteWord
0Dh
Read/write CONFIG1 register
ReadWord/WriteWord
0Eh
Read/write CONFIG2 register
ReadWord/WriteWord
0Fh
Read/write CONFIG3 register
ReadWord/WriteWord
10h
Read/write alert temperature for socket 0
ReadWord/WriteWord
11h
Read/write alert temperature for socket 1
ReadWord/WriteWord
12h
Read/write alert temperature for socket 2
ReadWord/WriteWord
13h
Read/write alert temperature for socket 3
ReadWord/WriteWord
14h
Request polling
SendByte
15h
Clear alert
SendByte
Configuration
The MAX6621 has four configuration registers (Table 1).
CONFIG0 is the main configuration register that enables
the PECI sockets, I2C bus timeout, PEC, alert activation,
and polling delay. CONFIG1 sets the number of retries,
CONFIG2 sets the temperature offset, and CONFIG3
controls the temperature averaging. You can write to
the configuration registers to set the configuration or
read from the configuration registers to get the current
settings.
Table 1. Configuration Registers
6
COMMAND BYTE
REGISTER DESCRIPTION
TYPE
RESULT
0Ch
CONFIG0 register
ReadWord/WriteWord
See the CONFIG0 section.
0Dh
CONFIG1 register
ReadWord/WriteWord
See the CONFIG1 section.
0Eh
CONFIG2 register
ReadWord/WriteWord
See the CONFIG2 section.
0Fh
CONFIG3 register
ReadWord/WriteWord
See the CONFIG3 section.
_______________________________________________________________________________________
PECI-to-I2C Translator
Table 2. CONFIG0 Register
BIT(S)
DESCRIPTION
DEFAULT
15:8
Polling enable for sockets and domains
00h
15
1 = enable socket 3, domain 1
0
14
1 = enable socket 3, domain 0
0
13
1 = enable socket 2, domain 1
0
12
1 = enable socket 2, domain 0
0
11
1 = enable socket 1, domain 1
0
10
1 = enable socket 1, domain 0
0
9
1 = enable socket 0, domain 1
0
8
1 = enable socket 0, domain 0
0
7
1 = enable I2C bus lockup timeout
0 = disable timeout
1
6
1 = alternate data representation
0 = 16-bit data representation
0
5
1 = enable I2C packet error checksum
(PEC) on device return data
0 = disable PEC
1
4
1 = mask temperature alerts
0 = activate alerts
0
3
2:0
The optional polling delay (bits 2:0) inserts after polling
the set of all sockets and domains that are enabled in
bits 15:8 with a minimal pause of 2.5ms between PECI
reads. After polling all enabled sockets and domains,
the device pauses PECI communications for the configured time before starting to poll the set of enabled
sockets and domains again. Table 3 shows the various
polling delay options.
Table 3. Polling Delay
POLL DELAY VALUE
DELAY BETWEEN POLLS (ms)
0
Polling on request only
1
2.5
2
5
3
10
4
50
5
100 (default)
6
500
7
Reserved
CONFIG1
The CONFIG1 register configures the maximum number of retries before aborting a PECI temperature read
as well as the originated (suggested) PECI bit time.
Table 4 shows the various options for CONFIG1.
Table 4. CONFIG1 Register
Reserved, set to 0
0
Poll delay, see Table 3
5
BIT(S)
DESCRIPTION
DEFAULT
15:8
Originated PECI bit time
(before negotiation)
01h: RESERVED
02h…0FFh: CONFIG1[15:8] + 1µs
Minimum: 02h (= 3µs / 333.3kHz)
Maximum: 0FFh (= 256µs / 3.906kHz)
02h
7:0
Maximum number of retries for PECI
transactions
03h
_______________________________________________________________________________________
7
MAX6621
CONFIG0
The CONFIG0 register holds a bit mask for sockets and
domains that are enabled for polling as well as a
polling delay (minimum delay between sets of polls)
and features enable/disable bits. Table 2 shows the
various options for CONFIG0.
MAX6621
PECI-to-I2C Translator
CONFIG2
The CONFIG2 register holds the offset that is added to
all temperature return values that are not error codes.
The offset is enabled in CONFIG0, bit 6; +95°C is set
as 17C0h or 005Fh, depending on the data format. To
represent +95°C in 16-bit representation, convert
+95°C to binary using two’s complement and left-shift
six times. The MAX6621 automatically converts the offset value to the equivalent value when the data format
is changed. See Table 5 for the default offset and Table
6 for some example values.
Temperature Representation
Temperature data is formatted in 16-bit two’s complement representing a range from -512°C to +512°C in
steps of 1/64°C (Figure 1). Internally, the device always
uses the 16-bit data format. The temperature is given in
two’s complement and left-shifted so that the +1°C bit
is bit 6 (Figure 2). Temperatures can be represented
externally in alternate data format if fractional readings
are not needed. Table 8 shows some examples.
Table 5. CONFIG2 Register
BIT(S)
15:0
1
°C
2
DESCRIPTION
Temperature offset
DEFAULT
0000h
Table 6. Example Offset Values in 16-Bit
Temperature Representation
HEX
0
RESLO
0000h
0000 0000
0000 0000
+25
0640h
0000 0110
0100 0000
+50
0C80h
0000 1100
1000 0000
+75
12C0h
0001 0010
1100 0000
+95
17C0h
0001 0111
1100 0000
When configured in CONFIG2, and the return code is not
an error code (see the Error Codes section), the device
adds the offset value stored in CONFIG2 to the return
value. For example, if the CPU’s thermal control circuit
activation point is at +95°C, CONFIG2 can be set to
+95°C (005Fh or 17C0h) and all return values are converted to absolute temperatures. Note that the thermal
control circuit activation point is CPU specific. The offset
value is represented in the current data format.
CONFIG3
CONFIG3 register configures the temperature averaging
function. See the Temperature Averaging section for
more information. Table 7 shows the default settings.
5
4
3
2
1
°C
4
1°C
1
0
1
°C
16
1
°C
64
Figure 1. Temperature Measured in 1/64°C Steps
-50°C
TWO'S
COMPLEMENT
15 14 13 12 11 10
1 1 0 0
9
8
RESHI
7
1 1 1 0
6
5
4
3
2
1
0
RESLO
Figure 2. Conversion of Temperature Done in Two’s
Complement
Table 8. Example 16-Bit Representation
with No Offset (Activation Point = +95°C)
TEMP
(°C)
Table 7. CONFIG3 Register
RELATIVE
TEMP (°C)
HEX
BINARY
RESHI
RESLO
DEFAULT
+94
-1
FFC0h
1111 1111
1100 0000
15:8
Reserved, set to 0
00h
+85
-10
FD80h
1111 1101
1000 0000
7:0
Averaging shift count, see formula
00h
+70
-25
FDC0h
1111 1101
1100 0000
+45
-50
F380h
1111 0011
1000 0000
+20
-75
ED30h
1110 1101
0100 0000
BIT(S)
8
6
BINARY
RESHI
1
°C
32
RESLO
7
TEMP (°C)
1
°C
8
DESCRIPTION
_______________________________________________________________________________________
PECI-to-I2C Translator
Temperature Averaging
The MAX6621 can average several temperature readings and return a value as calculated by:
TNEW =
1
1
⎛
⎞
x TPECI + ⎜1 −
⎟ x TOLD
⎝
2CONFIG3
2CONFIG3 ⎠
where TOLD is the previously stored temperature, TPECI
is the new value read from PECI, and TNEW is the newly
stored temperature ready to be returned through I2C.
This calculation can cause significant bits to be lost.
Enable temperature averaging by writing the desired
averaging amount to the CONFIG3 register. Writing 00h
to the CONFIG3 register disables temperature averaging.
FRACTIONAL VALUE
RESLO
RESHI
Table 9. Alternate Temperature
Representation
DESCRIPTION
16-bit value
Alternate
representation
RESHI
RESLO
15:14:13:12:11:10:9:8
7:6:5:4:3:2:1:0
15:15:15:15:15:15:15:15 15:12:11:10:9:8:7:6
S
X
X
12
11
10
9
8
7
6
X
X
X
X
X
X
S
S
S
S
S
S
S
S
S
12
11
10
9
8
7
6
(SIGN BITS)
INTEGER VALUE (~ 1°C)
Figure 3. Alternate Temperature Representation
Table 10. Example Alternate Representation with No Offset (Activation Point = +95°C)
BINARY
TEMP (°C)
RELATIVE TEMP (°C)
HEX
RESHI
RESLO
+94
-1
FFFFh
1111 1111
1111 1111
+85
-10
FFF6h
1111 1111
1111 0110
+70
-25
FFE7h
1111 1111
1110 0111
+45
-50
FFCEh
1111 1111
1100 1110
+20
-75
FFB5h
1111 1111
1011 0101
_______________________________________________________________________________________
9
MAX6621
Alternate Temperature Value Representation
This optional feature can be enabled using bit 6 of
CONFIG0. When the alternate data format is enabled, the
temperature value is shifted right as shown in Table 9.
The most significant bits are set to all 0s or all 1s depending on the sign bit 15, also shown as S in Figure 3. Table
10 shows some example values. This translation is not
performed for error codes (16-bit values from 8000h
through 81FFh).
Excluding error codes, the software only has to examine the RESLO data byte, as it represents an integer
value in the range from -128°C to +127°C in 1°C steps.
The RESHI byte is all 0s or all 1s for valid return codes,
and either 80h or 81h for all error codes.
MAX6621
PECI-to-I2C Translator
Temperature Commands
Table 11 shows the different commands for selecting
one of the PECI hosts or getting the maximum temperature. Read commands are initiated by the MAX6621,
and the result returned is a 16-bit word with the least
significant bit (LSB) clocked in first for the selected
PECI host.
The result consists of RESLO for the 8 LSBs and RESHI
for the 8 MSBs, resulting in a 16-bit word. The 16-bit
words are temperature values read from the PECI interface. PECI-enabled Intel microprocessors return temperature data in fractions of 1°C below the
thermal-control-circuit activation point, resulting in negative return values that do not represent absolute temperatures. Absolute temperatures can be achieved by
setting the temperature offset in CONFIG2.
Table 12 shows example return values for an Intel CPU.
Note that the MAX6621 does not interpret the return
Table 11. Read Temperature
ADDRESS
REGISTER
00h
Socket 0, domain 0
01h
Socket 0, domain 1
02h
Socket 1, domain 0
03h
Socket 1, domain 1
04h
Socket 2, domain 0
05h
Socket 2, domain 1
06h
Socket 3, domain 0
07h
Socket 3, domain 1
08h
Read maximum temperature for all enabled
sockets/domains
TYPE
RESULT
ReadWord
16-bit words
Table 12. Return Temperature Values
RELATIVE
TEMPERATURE (°C)
-1
-36
-37
-38
-39
-40
-41
-42
-43
10
CONFIG2
RESHI:RESLO
16 BITS
ALTERNATE
16 BITS
ALTERNATE
0000
0000
FFC0
FFFF
17C0
005F
1780
005E
0000
0000
F700
FFDC
17C0
005F
0ec0
003B
FFDB
0000
0000
F6C0
17C0
005F
0E80
003A
0000
0000
F680
FFDA
17C0
005F
0E40
0039
0000
0000
F640
FFD9
17C0
005F
0E00
0038
FFD8
0000
0000
F600
17C0
005F
0DC0
0037
0000
0000
F5C0
FFD7
17C0
005F
0D80
0036
0000
0000
F580
FFD6
17C0
005F
0D40
0035
0000
0000
F540
FFD5
17C0
005F
0D00
0034
______________________________________________________________________________________
PECI-to-I2C Translator
Table 13. Read Maximum Temperature
Address
COMMAND
DESCRIPTION
0Ah
Read address of
socket/domain with the
maximum temperature
TYPE
MAX6621
data (with the exception of error codes) and the relative
temperatures are listed for reference only. Table 12
shows the values with 16-bit and alternate word format.
The read maximum temperature command from Table 11
returns the highest temperature that is not an error
code from the enabled PECI sockets and domains. This
operation works on signed numbers only and does not
give information as to what socket the temperature
result comes from. To find the socket and domain, use
the read maximum temperature address command as
shown in Table 13.
DATA FROM PECI
Y
N
ERROR?
AVERAGING
N
ALT.
FORMAT?
RESULT
Y
ReadWord
16-bit
The read maximum temperature address command
returns the register that had the highest temperature
when read maximum temperature was last called. An
error is returned if the read maximum temperature has
not been called or when the read maximum temperature itself returns an error.
Return Value Flow Chart
Figure 4 shows the operations performed on temperature data read through PECI.
CONVERT
DATA
FORMAT
ADD OFFSET
RETURN DATA ON I2C
Figure 4. Operational Flowchart
______________________________________________________________________________________
11
MAX6621
PECI-to-I2C Translator
Error Codes
Error codes are represented as 16-bit words in the
8000h–81FFh range as shown in Table 14.
Table 15. Read/Write Temperature Alert
Commands
COMMAND
Table 14. Error Codes
ERROR
CODES
DESCRIPTION
8000h–
80FFh
Refer to Intel PECI specification.
8100h
PECI transaction failed for more than the
configured number of consecutive retries.
8101h
Polling disabled for requested socket/domain.
8102h
First poll not yet completed for requested
socket/domain (on startup).
8103h
Read maximum temperature requested, but no
sockets/domains enabled or all enabled
sockets/domains have errors; or read maximum
temperature address requested, but read
maximum temperature was not called.
8104h
Get alert socket/domain requested, but no alert
active.
ALERT Output
The MAX6621 asserts ALERT when a PECI temperature
exceeds a configurable threshold after averaging.
Table 15 below shows the registers that set the threshold and read the alert temperature for each socket. If
there are no active alerts, an error is returned as shown
in Table 14. If polling is disabled, the alert temperatures
are only checked when the request polling command is
called.
Once ALERT is asserted, a subsequent drop in temperature does not clear the alert. ALERT must be cleared
by calling the clear alert command.
DESCRIPTION
TYPE
DEFAULT
10h
Read/write alert
temperature for
socket 0
ReadWord/
WriteWord
7FFFh
11h
Read/write alert
temperature for
socket 1
ReadWord/
WriteWord
7FFFh
12h
Read/write alert
temperature for
socket 2
ReadWord/
WriteWord
7FFFh
13h
Read/write alert
temperature for
socket 3
ReadWord/
WriteWord
7FFFh
Clear Alert
The clear alert is shown in Table 16, and this command
clears an active alert. If the temperature still exceeds
one of the thresholds after clearing, ALERT reasserts
on the next PECI temperature read. New alerts are disabled when mask alerts (CONFIG0, bit 4) is set. This
does not affect an existing alert. The clear alert command needs to be called to clear it.
Table 16. Clear Alert
COMMAND
15h
DESCRIPTION
Clear alert
TYPE
SendByte
Read Alert Socket/Domain
Table 17 shows the read alert socket/domain command. Call this command to check for the socket/
domain (register) that caused the alert to become
active. If multiple temperatures exceed their respective
thresholds, only the first violation is recorded. Register
address is held in low byte.
Table 17. Read Alert Socket/Domain
12
COMMAND
DESCRIPTION
TYPE
0Bh
Read alert socket
and domain
ReadWord
______________________________________________________________________________________
RESULT
16-bit word
PECI-to-I2C Translator
The result is a 16-bit word (low byte transmitted first,
high byte second), e.g., 0100h for the MAX6621 firmware
version 1.0.
RESET
The MAX6621 operates as a slave that sends and
receives data through an I2C-compatible, 2-wire interface. The interface uses a serial-data line (SDA) and a
serial-clock line (SCL) to achieve bidirectional communication between master and slave. A master (typically
a microcontroller) initiates all data transfers to and from
the MAX6621 and generates the SCL clock that synchronizes the data transfer (Figure 5).
The MAX6621 features a power-on reset (POR), bus
lockout reset, and a reset input (RESET). The power-on
reset monitors VCC and holds all outputs in high impedance until V CC passes the POR threshold. The
MAX6621 monitors VCC for brownout conditions even
after power-up.
Bus Lockout Timeout Reset
If an I 2 C transaction starts and gets locked up for
greater than 20ms, the MAX6621 asserts the internal
bus lockup reset that restarts itself in the default startup
condition.
RESET Input
The MAX6621 features a RESET input that allows users
to directly reset to the default startup conditions. Pull
RESET low for a minimum of 10ns for a valid reset. The
MAX6621 requires 100µs to be accessible after RESET
has been asserted.
Version Information Command
Table 18 shows the command to read the firmware version.
Table 18. Firmware Command
COMMAND
09h
DESCRIPTION
Get firmware
version
TYPE
ReadWord
RESULT
16 bit word
Serial Interface
The MAX6621 SCL and SDA lines operate as both
inputs and open-drain outputs. A pullup resistor is
required on SCL and SDA.
Each transmission consists of a START condition sent
by a master, followed by the MAX6621 7-bit slave
address, plus an R/W bit, one or more data bytes, and
finally a STOP condition (Figure 6). To write to a
MAX6621 register, a write transmission consists of a
START condition, followed by the MAX6621 7-bit slave
address plus R/W = 0, a register address byte, one
data byte, and finally a STOP condition. To read from a
MAX6621 register, a combined write and read transmissions are required. The first write transmission consists of a START condition, followed by the MAX6621
7-bit slave address plus R/W = 0, a register address
byte, and finally a STOP condition that sets the register
to be read. The second read transmission consists of a
START condition, followed by the MAX6621 7-bit slave
address plus R/W = 1, one or more data bytes, and
finally a STOP condition that reads the data from the
SDA
tSU, DAT
tBUF
tSU, STA
tLOW
tHD, STA
tHD, DAT
tSU, STO
SCL
tHIGH
tHD, STA
tR
tF
START
CONDITION
REPEATED START
CONDITION
STOP
CONDITION
START
CONDITION
Figure 5. 2-Wire Serial-Interface Timing Details
______________________________________________________________________________________
13
MAX6621
The result is a 16-bit word (low byte transmitted first,
high byte second) that contains the register that
caused ALERT to assert. An error (8103h) is returned
when there is no active ALERT.
MAX6621
PECI-to-I2C Translator
specified register. These write and read transmissions
can be joined using a repeated START even though the
MAX6621 7-bit slave address needs to be present preceding the R/W bits.
Start and Stop Conditions
Both SCL and SDA remain high when the interface is
not busy. A master signals the beginning of a transmission with a START (S) condition by transitioning SDA
from high to low while SCL is high. When the master
has finished communicating with the slave, it issues a
STOP (P) condition by transitioning SDA from low to
high while SCL is high. The bus is then free for another
transmission (Figure 6).
The acknowledge bit is a clocked 9th bit that the recipient uses to handshake receipt of each byte of data
(Figure 8). Thus, each byte transferred effectively
requires 9 bits. The master generates the 9th clock
pulse, and the recipient pulls down SDA during the
acknowledge clock pulse so that the SDA line is stable
low during the high period of the clock pulse. When the
master is transmitting to the MAX6621, the MAX6621
generates the acknowledge bit because the MAX6621
is the recipient. When the MAX6621 is transmitting to
the master, the master generates the acknowledge bit
because the master is the recipient.
CLOCK PULSE
FOR ACKNOWLEDGEMENT
START
CONDITION
SDA
SCL
1
2
8
9
SDA BY
TRANSMITTER
SDA BY
RECEIVER
SCL
S
P
START
CONDITION
STOP
CONDITION
S
Figure 8. Acknowledge
Figure 6. Start and Stop Conditions
Data Transfer and Acknowledge
One data bit is transferred during each clock pulse.
The data on SDA must remain stable while SCL is high
(Figure 7).
Slave Address
The MAX6621 has a 7-bit long slave address (Figure 9).
The 8th bit following the 7-bit slave address is the R/W
bit. The R/W bit is low for a write command and high for
a read command.
SDA
SDA
0
1
0
1
A2
A1
SCL
SCL
DATA LINE STABLE; CHANGE OF DATA
DATA VALID
ALLOWED
Figure 7. Bit Transfer
14
Figure 9. Slave Address
______________________________________________________________________________________
A0
ACK
PECI-to-I2C Translator
values for A2:A1 available by factory programming.
Therefore, a maximum of four MAX6621 devices can be
controlled independently from the same interface (see
the I2C Address Range section).
TYPICAL READ WORD COMMAND
PEC (PACKET ERROR CHECKSUM) ENABLED
MASTER
ADDR:7
W
A
CMD:8
A
MAX6621
ADDR:7
R
A
RESLO:8
A
RESHI:8
A
PEC:8
NA
P
PEC (PACKET ERROR CHECKSUM) DISABLED
MASTER
ADDR:7
W
A
CMD:8
A
MAX6621
ADDR:7
R
A
RESLO:8
A
RESHI:8
NA
A
CMD:8
A
INLO:8
A
INHI:8
A
CMD:8
A
INLO:8
A
INHI:8
A
P
TYPICAL WRITE WORD COMMAND
COMMAND WITH PEC (PACKET ERROR CHECKSUM)
MASTER
S
ADDR:7
W
PEC:8
A
P
COMMAND WITHOUT PEC (PACKET ERROR CHECKSUM)
MASTER
ADDR:7
S
W
A
P
THE RESULT CONSISTS OF RESLO FOR THE 8 LEAST SIGNIFICANT BITS (LSBS) AND RESHI FOR THE 8 MOST SIGNIFICANT BITS (MSBS), RESULTING IN A 16-BIT WORD.
TEMPERATURE DATA AND ERROR CODES ARE GIVEN AS 16-BIT WORDS.
ADDR:7: 7-BIT ADDRESS FOLLOWED BY A READ (R = 1) OR WRITE (W = 0) BIT TO FORM THE 8-BIT ADDRESS USED IN THE I2C/SMBUS PROTOCOL.
P: I2C STOP CONDITION. SEE FIGURE 6.
S: I2C START CONDITION. SEE FIGURE 6.
A: ACK. THE PULSE ON THE 9th CLOCK CYCLE TO INDICATE ACKNOWLEDGE TRANSFER. SLAVE PULLS LOW TO GND AND MASTER PULLS TO SLAVE'S VOL.
NA: NOT ACKNOWLEDGE
CMD: COMMAND BYTE
RESLO: LEAST SIGNIFICANT 8-BIT RESULT
RESHI: MOST SIGNIFICANT 8-BIT RESULT
Figure 10. Typical Read/Write Word Command
______________________________________________________________________________________
15
MAX6621
The first four bits of the MAX6621 slave address
(A6:A3) are always 0101. Bits A2:A1 are set during the
manufacturing process to 0:1 (A2:A1 = 1:0 is a factory
option). A0 is selected by the address input AD0. AD0
can be connected to GND or VCC. The MAX6621 has
two possible slave addresses selectable by AD0, and
MAX6621
PECI-to-I2C Translator
Table 19. MAX6621 Slave Addresses
A6:A3
(FIXED)
A2:A1
(FACTORY SET)
A0
(SET BY AD0 PIN)
SLAVE
ADDRESS
I2C ADDRESS BYTE
INCLUDING R/W BIT
0101
01
0
2Ah
54h, 55h
0101
01
1
2Bh
56h, 57h
0101
10
0
2Ch
58h, 59h
A2:A1 = 10 is a factory option
0101
10
1
2Dh
5Ah, 5Bh
A2:A1 = 10 is a factory option
Message Format for Writing to the MAX6621
A write to the MAX6621 consists of the transmission of
the MAX6621’s slave address with the R/W bit set to
zero, followed by at least 1 byte of information. The first
byte of information is the command byte. The command byte determines which register of the MAX6621
is to be written to by the next byte or read from during
the next read transmission. If a STOP condition is
detected after the command byte is received, the
MAX6621 takes no further action beyond setting the
register address.
The bytes received after the command byte are data
bytes. The data bytes go into the register of the
MAX6621 specified by the command byte. Only the last
data byte or word transmitted before a STOP condition
is stored by the device (Figure 10).
Message Format for Reading the MAX6621
The MAX6621 is read using the MAX6621’s internally
stored command byte as an address pointer the same
way the stored command byte is used as an address
pointer for a write. The pointer autoincrements after
each data byte is read. Thus, a read is initiated by first
configuring the MAX6621’s command byte by performing a write. The master can now read N consecutive
bytes from the MAX6621 with the first data byte being
read from the register addressed by the initialized command byte (Figure 10).
Packet Error Checksum (PEC)
All MAX6621 I2C packets have an optional packet error
checksum (PEC). The PEC is implemented in accordance with the SMBus specification, versions 1.1 and
2. The MAX6621 accepts commands with or without
PEC. The PEC for device responses is optional and can
be disabled in the CONFIG0 register.
16
Applications Information
Operation with Multiple Masters
If the MAX6621 is operated on a 2-wire interface with
multiple masters, a master reading the MAX6621 should
use a repeated START between the write that sets the
MAX6621’s address pointer, and the read(s) that takes
the data from the location(s) (Table 19). This is because
it is possible for master 2 to take over the bus after master 1 has set up the MAX6621’s address pointer, but
before master 1 has read the data. If master 2 subsequently changes the MAX6621’s address pointer, master
1’s delayed read can be from an unexpected location.
The use of multiple masters is not recommended.
I2C Address Range
In addition to the four MSBs (0101), the I 2 C slave
address includes bit A0 (set by the address input AD0)
and bits A2:A1 (set as a factory option to 01 or 10).
Using A2:A0, the address can be configured from 2Ah
to 2Dh (Table 19).
Choosing Pullup Resistors
I2C requires pullup resistors to provide a logic-high
level to data and clock lines. There are tradeoffs
between power dissipation and speed, and a compromise must be made in choosing pullup resistor values.
Every device connected to the bus introduces some
capacitance even when the device is not in operation.
I2C specifies a minimum 300ns rise time to go from low
to high (30% to 70%) for fast mode, which is defined for
a date rate of 400kbps (refer to the I2C specifications
for details). To meet the rise time requirement, choose
pullup resistors so that the rise time tR = 0.85RPULLUP
x CBUS < 300ns. For typical low bus capacitances, a
4.7kΩ resistor can be used. For a bus capacitance of
400pF, choose a pullup resistor less than 880Ω. Many
I2C devices work when the minimum specified rise time
is not met. However, if the time it takes for the waveform
to rise becomes too slow, these waveforms are not recognized by the master.
______________________________________________________________________________________
PECI-to-I2C Translator
Chip Information
PROCESS: CMOS
TOP VIEW
PECI 1
+
10 VREF
9
ALERT
8
RESET
4
7
GND
5
6
VCC
AGND
2
AD0
3
SDA
SCL
MAX6621
μMAX
______________________________________________________________________________________
17
MAX6621
Pin Configuration
Package Information
(The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information,
go to www.maxim-ic.com/packages.)
e
10LUMAX.EPS
MAX6621
PECI-to-I2C Translator
4X S
10
10
INCHES
H
Ø0.50±0.1
0.6±0.1
1
1
0.6±0.1
BOTTOM VIEW
TOP VIEW
D2
MILLIMETERS
MAX
DIM MIN
0.043
A
0.006
A1
0.002
A2
0.030
0.037
0.120
D1
0.116
0.118
0.114
D2
0.116
0.120
E1
0.118
E2
0.114
0.199
H
0.187
L
0.0157 0.0275
L1
0.037 REF
b
0.007
0.0106
e
0.0197 BSC
c
0.0035 0.0078
0.0196 REF
S
α
0°
6°
MAX
MIN
1.10
0.15
0.05
0.75
0.95
3.05
2.95
3.00
2.89
3.05
2.95
2.89
3.00
4.75
5.05
0.40
0.70
0.940 REF
0.177
0.270
0.500 BSC
0.090
0.200
0.498 REF
0°
6°
E2
GAGE PLANE
A2
c
A
b
A1
α
E1
L
D1
L1
FRONT VIEW
SIDE VIEW
PROPRIETARY INFORMATION
TITLE:
PACKAGE OUTLINE, 10L uMAX/uSOP
APPROVAL
DOCUMENT CONTROL NO.
21-0061
REV.
1
1
Revision History
Pages changed at Rev 1: 2, 5, 14, 15, 16, 18
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
18 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600