FC SERIES ELECTRONIC INDICATOR DATA SHEET PNJ3 The FC series electronic indicator uses a solid state indicator as an indicating element, completely eliminating the need for mechanical moving parts and provides high reliability. Use of two indicating elements has enabled arrangement of many monitoring points in a limited space, which is useful to compare monitoring points influenced by one another. FEATURES 1. Outstanding reliability The adoption of a solid state indicator has completely eliminated the need for mechanical moving parts, providing excellent reliability. 2. Two-point indicator This instrument indicates 2 different values at the same time, so a large number of monitoring points can be arranged in a small space, whereby monitoring points influenced by one another can easily be compared and indicated. 3. International standards This instrument is compact in size, conforming to the international standards of IEC. It operates on 24V DC power to deliver 1 to 5V DC signals as recommended by IEC standards. 100V and 200V AC power are also available for convenience of operation. It also accepts a thermocouple, a resistance bulb or a 4 to 20mA DC input converter optionally. 4. Digital indication/setting function Input signals can be read accurately from the digital indicator on the front panel. Various parameters can also be set on the front of the panel. FUNCTIONAL DIAGRAM EDS11-117c Date Jan. 27, 1999 PNJ3 4. Power failure processing functions SPECIFICATIONS 1. Input signal (1) Analog input signal: 2 points Indicating input 1* AI1 Indicating input 2* AI2 1 to 5V DC Input resistance, 1MΩ or more Allow. error ± 0.2%/FS * Indicating input 1 select from the following inputs. 24V DC power supplied to transmitter during AC operation Allow. error ± 0.2%/FS Type I+ J:0 to 600°C I0 K:0 to 1200°C E:0 to 800°C I– R:0 to 1600°C 10mV DC span or more Allow. error ± 0.5%/FS* Pt100 –50 to 500°C 50°C span or more Current input signal Termocouple input 4 to 20mA DC Resistance bulb input Basic contact compensating function Allow. error ± 0.5%/FS 2. Output signal (1) Analog output signal: 2 points Indicating input 1 com- AO1 pensation Indicating input 2 com- AO2 pensation 1 to 5V DC Output resistance, 1Ω or less Allow. error ± 0.2%/FS FLT High alarm output 1 H1 Low alarm output 1 L1 High alarm output 2 H2 L2 Low alarm output 2 Input signal abnormality: FLT lamp lights, FLT contact output "ON". Indication of abnormal contents: Cause of abnormality indicated in numerical values on front panel. 6. Other functions 7. Operating conditions Open-collector output (photocoupler insulation) Power supply: Output rating, 30V x 0.1A DC max. 3. Indication, alarm, setting, functions (1) Bar graph indication Indication method 5. Self-diagnosis functions Data protective function by pass code (2) Digital output signal: 5 points Fault output Power failure detection: Alarm output "OFF" at power failure detection. During power failure: Data backed up by capacitor within 5 minutes. Alarm set data stored in nonvolatile memory (more than 10 years at ambient temperature of 50°C or less). Power failure recovery: Initial or continuous start set within 5 minutes of power failure. Recovery from power failure exceeding 5 minutes is initial. PV indicator GV indicator LED (red) LED (green) No. of indicating segments 101 + 2 101 + 2 Indication range 0 to 100% linear 0 to 100% linear Indication resolution 1 %/FS 1%/FS Scale length 100mm 100mm Indication mode 0 to 100% bar graph indication, 0 to 100% reverse bar graph indication, 0 to 100% dot indication (2) Numerical value indication/setting Indicating method: LED (red), name in 3 digits + numerical value in 5 digits (negative code included) Contents of indication: Indicating input signal (industrial value), high/low alarm, etc. Contents of indication select by use of F/S, , , keys on front panel. Setting method: By use of F/S, , , , ST keys on front panel. (3) Alarm functions High/low alarm set in industrial values for display of indicating signal. Indicating method: Two LED lamps (red) on front panel ..... High alarm indicator ..... Low alarm indicator Select from 3 types 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) Power consumption: Approx. 11W (DC) Approx. 20VA (AC) Dielectric strength: 1500V AC, 1 min. Insulation resistance: 500V DC, 100MΩ or more Ambient temperature: 0 to 50°C Ambient humidity: 90% RH or less Enclosure: Steel case Nameplate: 100 (H) x 70 (W) mm, white acryl Dimensions: 144 (H) x 72 (W) x 407 (D) mm, IEC (DIN) standards Mass {weight}: Approx. 2.9kg Mounting method: Flush in door mounting; vertical mounting. Mountable on tilted surface, angle "α" α=0° to 90° Finish color: Munsell N1.5 for both front panel and case Range of delivery:Electronic indicator and mounting bracket CODE SYMBOLS 1 2 3 4 5 6 7 8 PN J 3 Description 5 ndicating input 1 1 to 5V DC 4 to 20mA DC with 24V DC power supply J thermocouple 10mV DC span or K thermocouple more E thermocouple Basic contact comR thermocouple pensating function Resistance bulb, Pt100, 3-wire, 50°C span or more A B C D E F G The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN510402. The applicable standards used to demonstrate compliance are :- EN 55011 : 1991 CLASS A Conducted and Radiated emissions EN 50082-1 :-1992 Radiated immunity, ESD and FBT IIndicating input 2 1 to 5V DC 4 to 20mA DC with 24V DC power supply A C Power supply 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) 1 2 3 OUTLINE DIAGRAM (Unit:mm) Panel thickness 8mm or less 16 144 Terminals 52 Mounting bracket 200min. Supporting bracket 72 355 Panel cutout When mounting "n" units 68 +0.7 0 138 138 +1 0 +1 0 200min. 250min. When mounting 1 unit (72.2n – 4) +1 0 No. of units n 2 PNJ3 CONNECTION DIAGRAMS Compression terminal 01 AI (Indicating input2) I+ 31 02 AI2 I0 32 03 I– 33 04 AO1 34 05 AO2 35 06 AI, AO Common bus 1 to 5VDC signal output – + DC power for Transmitter DO (High alarm output) DO (Low alarm output) 36 07 SC SC 37 08 SC SC 38 09 SO1 39 10 IR1 40 11 IO1 41 12 H1 42 13 L1 43 14 44 15 45 DO (High alarm output) DO (Low alarm output) DO (FLT output) 24VDC power for DI, DO 18 FLT – 19 PCD VPD 49 + 24VDC power for DI, DO – 20 PCD VPD 50 + Instrument power (24VDC) – 21 PC * VP * 51 + 16 H2 46 17 L2 47 AI (Indicating input 1) AO Analog output 1 AO Analog output 2 AI, AO Common bus 48 G AC AC 71 72 73 24VDC power for DI, DO Instrument power (24VDC) Note: * Symbols for AC instrument power are VPO, PCO. Output : approx. 24V DC (0.1A max.) Ground Instrument power (AC) Instrument power (AC) Connections for indicating input 1 terminals 1 to 5V DC The 5th digit of code symbols "A" 4 to 20mA DC The 5th digit of code symbols "B" + Thermocouple The 5th digit of code symbols C,D,E,F 31 32 + – 33 + 31 Resistance bulb The 5th digit of code symbols G,W 32 – – 33 + 31 – 33 + + 31 – – 33 + 31 – 33 32 32 + 4 to 20mA DC power supply The 5th digit of code symbols "B" – 32 PC 21 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan