MPM-04E Series Low Cost, Board Mount 4W Single And Dual Output AC/DC Power Supplies Key Features: Electrical Specifications • 4W Output Power • Miniature Size • EN 60950 Approved (UL) • ErP Directive Compliant • Universal 85-264 VAC Input • Meets IEC Safety Class II • Single and Dual Outputs • Meets EN 55022 B Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Input Frequency Input Current Inrush Current EMI Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation, See Note 3 Load Regulation, Single Output Load Regulation, Single Output Load Regulation, Dual Output, See Note 4 Ripple/Noise (20 MHz) Ripple/Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, See Note 4 Overload Protection, See Note 5 General Parameter Isolation Voltage Isolation Resistance EMI/RFI EMC Compliance MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Switching Frequency Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Safety Standards Safety Class ECO Design Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 15.0 230 VAC 25.0 Meets CISPR Pub. 22/FCC Class B Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Note 2 ±1.0 ±0.5 VIN = Min to Max 3.3V output, IO = 0% to 100% ±1.0 5V to 24V output, IO = 0% to 100% ±0.5 IO = 10% to 100% ±0.5 Single 3.3V & 5V Outputs 100 All Other Models 0.8 115 VAC 20 ±0.01 Zener Diode Clamp 120 Continuous (Autorecovery) 105 Conditions Input to Output 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Conducted Disturbances Power Frequency Field Immunity Voltage Dip, Interruption & Variation Min. 3,000 100 Typ. Max. 264 370 440 Units VAC VDC Hz A Pk Max. Units ±1.0 ±1.0 ±1.5 ±1.0 ±1.0 150 1.0 % % % % % mVP-P %VP-P of VO mSec ±0.02 %/°C % of VO % of IO Max. Units VAC M⍀ EN 55022 Level B EN 61000-4-2 Level B EN 61000-4-3 Level A EN 61000-4-4 Level B EN 61000-4-5 Level B EN 61000-4-6 Level B EN 61000-4-8 Level A EN 61000-4-11 Level B/C 130 kHz Conditions Min. Typ. Max. -25 +25 +60 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % 1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm) Non-Conductive Plastic & Fiberglass (UL94-V0) 0.91 Oz (26g) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 330 EN 60950 IEC 60536 Class II ErP Directive 2009/125/EC www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-04S-03E MPM-04S-05E MPM-04S-09E MPM-04S-12E MPM-04S-15E MPM-04S-24E MPM-04D-12E MPM-04D-15E MPM-04D-0503E MPM-04D-1205E Current (A) Output 1 Voltage 115 VAC 230 VAC (VDC) 0.082 0.065 3.3 0.082 0.065 5.0 0.077 0.065 9.0 0.076 0.065 12.0 0.076 0.065 15.0 0.076 0.065 24.0 0.076 0.065 +12.0 0.076 0.065 +15.0 0.072 0.065 +5.0 0.072 0.065 +12.0 Notes: 1. For models, MPM-04D-0503E and MPM-04D-1205E output voltage accuracy is specified as ±2% typical and ±5% Max. 2. For models, MPM-04D-0503E and MPM-04D-1205E line regulation is specified as ±0.5% typical/±1.0% Max for VO1 and ±1.0% typical/±3.0% Max for VO2. 2. For models, MPM-04D-0503E and MPM-04D-1205E load regulation is specified as ±0.5% typical/±1.0% Max for VO1 and ±2.5% typical/±5.0% Max for VO2. 4. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 5. Overload protection is provided by a foldback circuit. Extended operation under an overload condition could damage the unit. 6. Operation at under no load conditions will not damage these units. It is recommended that the minimum load values in the table above be used. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-04E series, a 1A/250 VAC slow blow should be used. Current (mA) Max. 1.200 800 444 333 267 167 +166 +133 +600 +250 Min. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 150.0 62.5 Output 2 Maximum Voltage Cap. Load (µF) 14,000 8,000 2,400 1,000 700 220 330 260 5,600 330 (VDC) Maximum Efficiency Cap. Load (%, Typ) Current (mA) Max. -12.0 -15.0 +3.3 +5.0 -166 -133 +150 +120 Min. (µF) 0.0 0.0 37.5 30.0 330 260 4,700 4,700 70 72 75 76 76 77 77 77 72 75 Mechanical Dimensions Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Derating Curve Pin Connections Pin Single Dual (±) Dual (Sep) 1 NC 2 NC 3 +VOUT +VOUT +VOUT1 4 -VOUT Common Common +VOUT2 5 NP -VOUT 6 AC-Neutral 7 AC-Line NC = No Connection NP = No Pin MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]