MPM-04V Series Compact, Board Mount 4W Ultra-Wide Input Range AC/DC Power Supplies Key Features: • 4W Output Power • Universal 90-305 VAC Input • Miniature Size • EN 60950 Approved (UL) • Meets IEC Safety Class II • Single and Dual Outputs • Meets EN 55022 B • >350 kHour MTBF Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. Typ. 90 120 47 See Model Selection Guide 115 VAC 15.0 230 VAC 25.0 Meets CISPR Pub. 22/FCC Class B Meets EN 55024 Input Voltage Range Input Frequency Input Current Inrush Current EMI EMC Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation, See Note 3 Load Regulation, Single Output Load Regulation, Single Output Load Regulation, Dual Output Load Regulation, Dual Output Ripple/Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, See Note 4 Overload Protection General Parameter Isolation Voltage Isolation Resistance EMI/RFI EMC Compliance MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Switching Frequency Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Note 2 ±2.0 ±0.5 3.3V Output, VIN = Min to Max ±0.2 5V to 24V Output, VIN = Min to Max 3.3V output, IO = 0% to 100% ±1.5 5V to 24V output, IO = 0% to 100% ±0.5 Vout 1, IO = 10% to 100% ±0.5 Vout 2, IO = 10% to 100% ±5.0 Single 3.3V & 5V Outputs 150.0 All Other Models 100.0 115 VAC 15 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) 105 120 Conditions Input to Output 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 100 Typ. Max. 305 430 440 Units VAC VDC Hz A Pk Max. Units % % % % % % mVP-P mSec %/°C % of VO % of IO Max. Units VAC M⍀ EN 55022 Level B EN 61000-4-2 Level B EN 61000-4-3 EN 61000-4-4 Level 3 2 kV EN 61000-4-5 Level 3 1kV/2 kV 132 kHz Conditions Min. Typ. Max. -40 +25 +70 -40 +125 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % 1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm) Non-Conductive Plastic & Fiberglass (UL94-V0) 0.91 Oz (26g) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 350 UL 60950, EN 60950 UL, cUL; File No. E245422 IEC 61140 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-04SV-03 MPM-04SV-05 MPM-04SV-08 MPM-04SV-09 MPM-04SV-12 MPM-04SV-14 MPM-04SV-15 MPM-04SV-24 MPM-04DV-0503 MPM-04DV-0805 MPM-04DV-1205 Output 1 (See Note 1) Output 2 (See Note 1) Maximum Efficiency Output Maximum Maximum Current (A) Current (mA) Current (mA) Voltage Voltage Power (%, Typ) Cap. Load Cap. Load (VDC) (W) 115 VAC 230 VAC (VDC) Max. Min. Max. Min. (µF) (µF) 0.075 0.055 3.3 1.200 0.0 14,000 3.96 70 0.075 0.055 5.0 800 0.0 8,000 4.0 72 0.075 0.055 8.0 500 0.0 2,700 4.0 74 0.075 0.055 9.0 444 0.0 2,400 4.0 75 0.075 0.055 12.0 333 0.0 1,000 4.0 76 0.075 0.055 14.0 286 0.0 750 4.0 76 0.075 0.055 15.0 267 0.0 700 4.0 76 0.075 0.055 24.0 167 0.0 220 4.0 77 0.085 0.065 +5.0 +600 0.0 5,600 +3.3 +150 0.0 4,700 3.5 72 0.085 0.065 +8.0 +375 0.0 1,000 +5.0 +120 0.0 4,700 3.6 74 0.085 0.065 +12.0 +250 0.0 330 +5.0 +120 1.2 4,700 3.6 75 Notes: 1. For dual output models, Output 1 is +Vo and Output 2 is +Vr. A 47 µF/25V ceramic capacitor must be connected from +Vo (pin 12) of dual output models to Common (pin 11). Without this capacitor, the unit may not meet all specifications. 2. For dual output models, output voltage accuracy is specified as ±2% for +Vo and ±5% for +Vr. 3. For dual output models, line regulation is specified as ±0.2% for +Vo and ±3% for +Vr. 4. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 5. Operation at under no load conditions will not damage these units. It is recommended that the minimum load values in the table above be used. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-04V series, a 3.15A/250 VAC slow blow should be used. Mechanical Dimensions Pin Connections Pin Single Dual 1 NC NC 7 AC-Neutral 9 AC-Line NC = No Connection Pin Single Dual 10 NC +Vr 11 -Vo Common 12 +Vo +Vo Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Derating Curve, Vin = 90-280 VAC Derating Curve, Vin = 280-305 VAC MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]