TI TL507

 SLAS041 − OCTOBER 1979 − REVISED OCTOBER 1988
D Low Cost
D 7-Bit Resolution
D Montonicity Over Entire A/D Conversion
D
D
D
D
D
D
P PACKAGE
(TOP VIEW)
ENABLE
CLK
GND
OUTPUT
Range
Ratiometric Conversion
Conversion Speed . . . Approximately 1 ms
Single-Supply Operation . . . Either
Unregulated 8-V to 18-V (VCC2 Input) or
Regulated 3.5-V to 6-V (VCC1 Input)
I2L Technology
Power Consumption at 5 V . . . 25 mW Typ
Regulated 5.5-V Output (≤1 mA)
1
8
2
7
3
6
4
5
RESET
VCC2
VCC1
ANALOG INPUT
FUNCTION TABLE
ANALOG
INPUT CONDITION
X
VI < 200 mV
Vramp > VI > 200 mV
VI > Vramp
description
ENABLE
L†
H
H
H
OUTPUT
H
L
H
L
† Low level on enable also inhibits the reset function.
H = high level, L = low level, X = irrelevant
The TL507 is a low-cost single-slope analog-todigital converter designed to convert analog
inputvoltages between 0.25 VCC1 and 0.75 VCC1
into a pulse-width-modulated output code. The
device contains a 7-bit synchronous counter, a
binary weighted resistor ladder network, an
operational amplifier, two comparators, a buffer
amplifier, an internal regulator, and necessary
logic circuitry. Integrated-injection logic (I2L)
technology makes it possible to offer this complex
circuit at low cost in a small dual-in-line 8-pin
package.
A high level on RESET clears the counter to zero,
which sets the internal ramp to 0.75 VCC. Internal
pulldown resistors keep RESET and ENABLE low
when not connected.
In continuous operation, conversion speeds of up to 1000 conversions per second are possible. The TL507
requires external signals for CLK, RESET, and ENABLE. Versatility and simplicity of operation, coupled with low
cost, makes this converter especially useful for a wide variety of applications.
The TL507C is characterized for operation from 0°C to 70°C, and the TL507I is characterized for operation from
−40°C to 85°C.
Copyright  1988, Texas Instruments Incorporated
! "# $!%
$ "! "! &! ! !' !
$$ ()% $ "!* $! !!) $!
!* "!!%
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
1
SLAS041 − OCTOBER 1979 − REVISED OCTOBER 1988
functional block diagram (positive logic)
Comparator 2
200 mV
5
ANALOG
INPUT
4
Output
CTR
R
MSB
R
2R
CLK
2
+
Comparator 1
4R
8R
RESET
ENABLE
8
1
16R
R
Regulator
32R
7
64R
LSB
−
+
6
0.25 VCC1
3
VCC2
VCC1
GND
indicates an n-p-n open-collector output.
schematics of inputs and outputs
EQUIVALENT OF ENABLE
AND RESET INPUTS
EQUIVALENT OF CLOCK
INPUT
EQUIVALENT OF ANALOG
INPUT
VCC1
75 kΩ
Nom
75 kΩ
Nom
100 kΩ
Nom
Input
Input
Input
Constant
Current
≈ 10 µA
Output
VCC1
10 kΩ
Nom
32 kΩ
Nom
Output
3 kΩ
Nom
2
24 kΩ
Nom
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
SLAS041 − OCTOBER 1979 − REVISED OCTOBER 1988
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC1 (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 V
Supply voltage, VCC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Input voltage at analog input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 V
Input voltage at ENABLE, CLK, and RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
On-state output voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V
Off-state output voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Continuous total dissipation at (or below) 25°C free-air temperature (see Note 2) . . . . . . . . . . . . . 1000 mW
Operating free-air temperature range: TL507C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 70°C
TL507I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
NOTES: 1. Voltage values are with respect to network ground terminal unless otherwise noted.
2. For operation above 25°C free-air temperature, derate linearly to 520 mW at 85°C at the rate of 8.0 mW/°C.
recommended operating conditions
MIN
NOM
MAX
Supply voltage, VCC1
3.5
5
6
V
Supply voltage, VCC2
8
15
18
V
Input voltage at ANALOG INPUT
0
5.5
V
±18
V
Input voltage at ENABLE, CLK, and RESET
High-level input voltage, VIH, RESET and ENABLE
2
UNIT
V
Low-level input voltage, VIL, RESET and ENABLE
0.8
V
On-state output voltage
5.5
V
Off-state output voltage
1.8
V
150
kHz
UNIT
Clock frequency, fclock
0
125
electrical characteristics over recommended operating free-air temperature range,
VCC1 = VCC2 = 5 V (unless otherwise noted)
regular section
PARAMETER
VCC1
ICC1
Supply voltage (output)
ICC2
Supply current
TEST CONDITIONS
VCC2 = 10 V to 18 V, ICC1 = 0 to − 1 mA
VCC1 = 5 V,
VCC2 open
VCC2 = 15 V,
VCC1 open
Supply current
MIN
TYP†
MAX
5
5.5
6
V
5
8
mA
7
10
mA
TYP†
MAX
inputs
VT+
VTVhys
IIH
PARAMETER
Positive-going threshold voltage‡
Negative-going threshold voltage‡
TEST CONDITIONS
MIN
4.5
0.4
CLK
Hysteresis (VT+ − VT−)
2
High-level input current
RESET, ENABLE, and CLK
IIL
Low-level input current
II
Analog input current
† All typical values are at TA = 25°C.
‡ These parameters are linear functions of VCC1.
VI = 2.4 V
VI = 18 V
VI = 0
VI = 4 V
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
130
UNIT
V
V
2.6
4
17
35
V
220
320
±10
µA
10
300
nA
µA
3
SLAS041 − OCTOBER 1979 − REVISED OCTOBER 1988
output section
PARAMETER
TEST CONDITIONS
IOH
IOL
High-level output current
Low-level output current
VOH = 18 V
VOL = 5.5 V
VOL
Low-level output voltage
IOL = 1.6 mA
MIN
5
TYP†
MAX
0.1
100
µA
10
15
mA
80
400
mV
MAX
UNIT
UNIT
operating characteristics over recommended operating free-air temperature range,
VCC1 = VCC2 = 5.12 V
PARAMETER
TEST CONDITIONS
MIN
TYP†
Overall error
± 80
mV
Differential nonlinearity
Zero error‡
See Figure 1
± 20
mV
Binary count = 0
± 80
mV
Scale error
Binary count =127
± 80
mV
Full scale input voltage‡
Binary count = 127
Propagation delay time from RESET or ENABLE
3.74
3.82
3.9
2
V
µs
† All typical values are at TA = 25°C.
‡ These parameters are linear functions of VCC1.
definitions
zero error
The absolute value of the difference between the actual analog voltage at the 01H-to-00H transition and the
ideal analog voltage at that transition.
overall error
The magnitude of the deviation from a straight line between the endpoints of the transfer function.
differential nonlinearity
The maximum deviation of an analog-value change associated with a 1-bit code change (1 clock pulse) from
its theoretical value of 1 LSB.
4
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
SLAS041 − OCTOBER 1979 − REVISED OCTOBER 1988
PARAMETER MEASUREMENT INFORMATION
SN74191
CLK
OUTPUTS
DOWN/UP
4
Test
Point
Analog Devices
AD562
(or equivalent)
SN74191
RIPPLE
CLOCK
5 kΩ
Bits 9 −12
CLK
TL507
4
Bits 5 −8 DAC
OUT
Bits 1− 4
OUTPUTS
DOWN/UP
TL081
−
ANALOG
INPUT
+
Single
Clock Pulse
5V
SN74191
OUTPUT
CLK
ENABLE
RESET
RIPPLE
CLOCK
100-kHz
CLK INPUT
CLK
OUTPUTS
DOWN/UP
4
Figure 1. Monotonicity and Nonlinearity Test Circuit
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
5
SLAS041 − OCTOBER 1979 − REVISED OCTOBER 1988
PRINCIPLES OF OPERATION
The TL507 is a single-slope analog-to-digital converter. All single-slope converters are basically voltage-to-time
or current-to-time converters. A study of the functional block diagram shows the versatility of the TL507.
An external clock signal is applied through a buffer to a negative-edge-triggered synchronous counter.
Binary-weighted resistors from the counter are connected to an operational amplifier used as an adder. The
operational amplifier generates a signal that ramps from 0.75 • VCC1 down to 0.25 • VCC1. Comparator 1
compares the ramp signal to the analog input signal. Comparator 2 functions as a fault defector. With the analog
input voltage in the range 0.25 • VCC1 to 0.75 • VCC1, the duty cycle of the output signal is determined by the
unknown analog input, as shown in Figure 2 and the Function Table.
For illustration, assume VCC1 = 5.12 V,
0.25 • VCC1 = 1.28 V
1 binary count +
(0.75 * 0.25) V
128
CC1 + 20 mV
0.75 • VCC1 − 1 count = 3.82 V
The output is an open-collector n-p-n transistor capable of withstanding up to 18 V in the off state. The output
is current limited to the 8- to 12-mA range; however, care must be taken to ensure that the output does not
exceed 5.5 V in the on state.
The voltage regulator section allows operation f rom either an unregulated 8- to 18-V VCC2 source or a regulated
3.5- to 6-V VCC1 source. Regardless of which external power source is used, the internal circuitry operates at
VCC1. When operating from a VCC1 source, VCC2 may be connected to VCC1 or left open. When operating from
a VCC2 source, VCC1 can be used as a reference voltage output.
3.82 V
Analog Input
Level 1
Ramp Input to
Comparator 1
Analog Input
Level 2
1.28 V
Output for
Input Level 1
Output for
Input Level 2
Figure 2
6
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Amplifiers
Data Converters
DSP
Clocks and Timers
Interface
Logic
Power Mgmt
Microcontrollers
RFID
RF/IF and ZigBee® Solutions
amplifier.ti.com
dataconverter.ti.com
dsp.ti.com
www.ti.com/clocks
interface.ti.com
logic.ti.com
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/lprf
Applications
Audio
Automotive
Broadband
Digital Control
Medical
Military
Optical Networking
Security
Telephony
Video & Imaging
Wireless
www.ti.com/audio
www.ti.com/automotive
www.ti.com/broadband
www.ti.com/digitalcontrol
www.ti.com/medical
www.ti.com/military
www.ti.com/opticalnetwork
www.ti.com/security
www.ti.com/telephony
www.ti.com/video
www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265