SCBS116B − JANUARY 1991 − REVISED MARCH 1994 • • • • • • • • • D OR DB PACKAGE (TOP VIEW) Replaces SN74ABT328 Low Output Skew for Clock-Distribution and Clock-Generation Applications TTL-Compatible Inputs and Outputs Distributes One Clock Input to Six Clock Outputs Polarity Control Selects True or Complementary Outputs Distributed VCC and GND Pins Reduce Switching Noise High-Drive Outputs (−15-mA IOH, 64-mA IOL) State-of-the-Art EPIC-ΙΙB BiCMOS Design Significantly Reduces Power Dissipation Package Options Include Plastic Small-Outline (D) and Shrink Small-Outline (DB) Packages GND 1Y2 2Y1 GND 2Y2 3Y GND 4Y 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 1Y1 1T/C VCC 2T/C A VCC 3T/C 4T/C description The CDC328 contains a clock-driver circuit that distributes one input signal to six outputs with minimum skew for clock distribution. Through the use of the polarity-control inputs (T/C), various combinations of true and complementary outputs can be obtained. The CDC328 is characterized for operation from − 40°C to 85°C. FUNCTION TABLE INPUTS T/C A OUTPUT Y L L L L H H H L H H H L logic symbol † A 1T/C 2T/C 3T/C 4T/C 12 1 15 13 N1 1 N2 2 16 2 10 N3 9 3 N4 4 2 3 5 6 8 1Y1 1Y2 2Y1 2Y2 3Y 4Y † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. EPIC-ΙΙB is a trademark of Texas Instruments Incorporated. Copyright 1994, Texas Instruments Incorporated !"# $ %&'# "$ (&)*%"# +"#', +&%#$ %! # $('%%"#$ (' #-' #'!$ '."$ $#&!'#$ $#"+"+ /""#0, +&%# (%'$$1 +'$ # '%'$$"*0 %*&+' #'$#1 "** (""!'#'$, • DALLAS, TEXAS 75265 • HOUSTON, TEXAS 77251−1443 POST OFFICE BOX 655303 POST OFFICE BOX 1443 2−1 SCBS116B − JANUARY 1991 − REVISED MARCH 1994 logic diagram (positive logic) 1T/C 15 16 2 2T/C A 4T/C 1Y2 13 3 2Y1 12 5 3T/C 1Y1 10 6 9 8 2Y2 3Y 4Y absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V Voltage range applied to any output in the high state or power-off state, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −18 mA Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50 mA Continuous total power dissipation at (or below) 25°C free-air temperature (see Note 2) . . . . . . . . 1000 mW Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed. 2. For operation above 25°C free-air temperature, derate to 478 mW at 85°C at the rate of 8.7 mW/°C. recommended operating conditions (see Note 3) MIN NOM MAX UNIT 4.75 5 5.25 V VCC VIH Supply voltage VIL VI Low-level input voltage IOH IOL High-level output current VCC −15 mA Low-level output current 64 mA ∆t / ∆v Input transition rise or fall rate fclock TA Input clock frequency High-level input voltage 2 Input voltage 0 Operating free-air temperature −40 NOTE 3: Unused inputs must be held high or low. 2−2 V 0.8 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • V V 5 ns / V 80 MHz 85 °C SCBS116B − JANUARY 1991 − REVISED MARCH 1994 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VIK VOH VCC = 4.75 V, VCC = 4.75 V, II = −18 mA IOH = − 15 mA VOL II IO‡ VCC = 4.75 V, VCC = 5.25 V, IOL = 64 mA VI = VCC or GND VCC = 5.25 V, VO = 2.5 V ICC VCC = 5.25 V, VI = VCC or GND MIN TYP† UNIT −1.2 V 2.5 V −15 Outputs high IO = 0, MAX Outputs low 20 Ci VI = 2.5 V or 0.5 V † All typical values are at VCC = 5 V, TA = 25°C ‡ Not more than one output should be tested at a time, and the duration of the test should not exceed one second. 0.55 V ±1 µA −100 mA 50 µA 30 mA 3 pF switching characteristics over recommended ranges of supply voltage and operating free-air temperature (see Figures 1 and 2) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A Any Y tPLH tPHL T/C Any Y tsk(o) A MIN TYP MAX 1.7 7 1.5 5.4 1.5 8 1.4 6.6 Any Y (same phase) 0.7 Any Y (any phase) 2.6 tr tf UNIT ns ns ns 1.2 ns 0.5 ns switching characteristics, VCC = 5 V ± 0.25 V, TA = 25°C to 70°C (see Figures 1 and 2) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A Any Y tsk(o) A • MAX 2.1 6.1 1.7 4.8 Any Y (same phase) 0.7 Any Y (any phase) 2.1 POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • MIN UNIT ns ns 2−3 SCBS116B − JANUARY 1991 − REVISED MARCH 1994 PARAMETER MEASUREMENT INFORMATION From Output Under Test CL = 50 pF (see Note A) 500 Ω LOAD CIRCUIT FOR OUTPUTS 3V Input (see Note B) 1.5 V 1.5 V 0V tPHL tPLH Output 2V 1.5 V 0.8 V 1.5 V 0.8 V tr VOH VOL tf VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns. Figure 1. Load Circuit and Voltage Waveforms 2−4 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • SCBS116B − JANUARY 1991 − REVISED MARCH 1994 PARAMETER MEASUREMENT INFORMATION A 1T/C 1Y1 tPLH1 tPHL1 tPLH5 tPHL5 tPLH2 tPHL2 tPLH6 tPHL6 tPLH3 tPHL3 tPHL7 tPLH7 tPLH4 tPHL4 tPHL8 tPLH8 1Y2 2T/C 2Y1 2Y2 NOTES: A. Output skew, tsk(o), from A to any Y (same phase), can be measured only between outputs for which the respective polarity-control inputs (T/C) are at the same logic level. It is calculated as the greater of: − The difference between the fastest and slowest of tPLH from A↑ to any Y (e.g., tPLHn, n = 1 to 4; or tPLHn, n = 5 to 6) − The difference between the fastest and slowest of tPHL from A↓ to any Y (e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6) − The difference between the fastest and slowest of tPLH from A↓ to any Y (e.g., tPLHn, n = 7 to 8) − The difference between the fastest and slowest of tPHL from A↑ to any Y (e.g., tPHLn, n = 7 to 8) B. Output skew, tsk(o), from A to any Y (any phase), can be measured between outputs for which the respective polarity-control inputs (T/C) are at the same or different logic levels. It is calculated as the greater of: − The difference between the fastest and slowest of tPLH from A↑ to any Y or tPHL from A↑ to any Y (e.g., tPLHn, n = 1 to 4; or tPLHn, n = 5 to 6, and tPHLn, n = 7 to 8) − The difference between the fastest and slowest of tPHL from A↓ to any Y or tPLH from A↓ to any Y (e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6, and tPLHn, n = 7 to 8) Figure 2. Waveforms for Calculation of tsk(o) • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 2−5 SCBS116B − JANUARY 1991 − REVISED MARCH 1994 2−6 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DLP® Products DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com www.dlp.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2009, Texas Instruments Incorporated