SpectrAlert® Advance Field-Selectable Mass Notification Devices Description System Sensor SpectrAlert® Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker strobes, alert printed devices and color lens attachments. System Sensor SpectrAlert Advance offers a wide range of mass notification devices, including plain non-fire printed devices, amber lens strobes and speaker strobes, alert printed devices and color lens strobe devices. The SWALERT, SWH-ALERT and SPSW-ALERT strobes and speaker strobes are designed with an amber colored lens mounted in a white housing to allow visual signaling for mass notification in compliance with ANSI/UL1638 – Standard for General Signaling Visible Appliances. The SW-ALERT, SWH-ALERT and SPSW-ALERT amber lens strobes and speaker strobes provide simple installation and instant compatibility with SpectrAlert Advance synchronized systems. Additional ALERT models are available with clear lenses that can be used with color lens strobe attachments to meet requirements for a range of mass notification applications. Furthermore, SpectrAlert Advance includes a wide variety of non-fire printed devices, including indoor and outdoor strobes, horn strobes and speaker strobes. As part of the SpectrAlert Advance line, all System Sensor mass notification devices include innovative features designed to increase product versatility and save time and money. For example, a plug-in design simplifies installation and reduces ground faults; a shorting spring on the mounting plate tests wiring continuity to speed installation and protect devices from damage; and field-selectable settings enable installers to quickly set each device to meet application requirements. SpectrAlert Features • Electrically compatible with legacy SpectrAlert products • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field-selectable candela settings of 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185 (refer to Candela Derating Table for equivalent candela ratings for UL 1971 ) • Rated for 32°F to 120°F (0°C to 49°C) • Plain weatherproof devices are NEMA 4X, IP56 (K designation in part number) • Plug-in design • Tamper resistant construction with Torx head mounting screw • Shorting spring on mounting plate for continuity check before device installation • Design minimizes device intrusion into the back box • Housing can be either wall or ceiling mounted • White plastic housings available with ALERT clearly visible in red letters • Amber lens strobes and speaker strobes available • Color lens attachments are easily used with any non-fire wall or ceiling strobe • Compatible with System Sensor synchronization protocol An ISO 9000-2000 Company SIGNALING Sync•Circuit™ is a trademark, and SpectrAlert® and System Sensor® are registered trademarks of Honeywell International Inc. ©2006 by ADT. All rights reserved. Unauthorized use of this document is strictly prohibited. MEA S4011 Approved 452-05-E 7125-1653:188 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60520 Rev. A page 1 of 5 ©2009 Honeywell International Inc. All rights reserved. SpectrAlert® Advance SW-ALERT and SWH-ALERT Amber Lens Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17.8-inch back box. SpectrAlert Advance speaker strobes shall mount to a 4 x 4 x 21/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit™ Module accessory, shall be powered from a noncoded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes, horn strobes and speaker strobes shall have field-selectable candela settings, including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177 and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ Listed to UL 1971(clear lens strobes) and shall be approved for fire protective service or shall be approved for fire protective service as listed in ANSI/UL 1638 (amber lens strobes). The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system Speaker Strobe Combination The speaker strobe shall be a System Sensor SpectrAlert Advance Model __________ Listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Outdoor Products SpectrAlert Advance outdoor strobes, horn strobes, and speaker strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half-inch and three-fourths-inch conduit entries. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411.16 x 411.16 x 21.8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Color Lens Strobe Attachment The System Sensor SpectrAlert Advance color lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with non-fire printed System Sensor strobe devices. They shall mount to any wall or ceiling strobe and be rated from minus 35 degrees to 151 degrees Fahrenheit. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ____ Listed to UL 1971 and UL 464 and shall be approved for fire protective service. Physical Specifications The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. Standard Operating Temperature: K Series Operating Temperature: Humidity Range: The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. The horn and horn strobe models shall operate on a coded or non-coded power supply. 32°F to 120°F -40°F to 151°F 10 to 93% non-condensing (indoor models) Dimensions: Wall-Mount Strobe and Horn Strobe (including lens): 5.6½ L x 4.7½ W x 2.5½ D (14.2 L x 11.9 W x 6.35D cm) SPS Speaker Strobe: (including lens and speaker) 6.0½ L x 5.0½ W x 4.7½ D (15.2 L x 12.7 W x 11.9 cm) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60520 Rev. A page 2 of 5 www.gamewell-fci.com Physical Specifications Dimensions: Ceiling-Mount Strobe (including lens): SPS Speaker Strobe: (including lens & speaker) UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8 - 17.5 Volts 16 - 33 Volts Candela DC FWR DC FWR 15* 123 128 66 71 15/75* 142 148 77 81 Standard 30* NA NA 94 96 Candela 75* NA NA 158 153 Range 95* NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 6.8½ diameter x 2.5½ D (17.2 diameter x 6.35 D cm) 6.8½ diameter x 4.8½ D (17.2 D x 12.2 D cm) Electrical/Operating Specifications Nominal Voltage (strobes & horn strobes): Regulated 12 DC/FWR or regulated 24 DC/FWR Nominal Voltage ( speakers): 25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers): 50 VDC Operating Voltage Range: 8 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Strobe Flash Rate: 1 flash per second Speaker Frequency Range: 400 to 4000 Hz Speaker Power: ¼, ½, 1, 2 watts Speaker Sound Output Part No. UL Reverberant (dBA @ 10 Ft.) SPS Series Two-Wire Horn/Strobe, STANDARD Candela Range (15 - 115 cd), UL Maximum Current Draw (mA RMS) 8 - 17.5 Volts DC Input 15 15/75 15 15/75 DC Input, Temporal High DC Input, Temporal, Medium DC Input, Temporal, Low DC Input, Non-temporal, High FWR Input, Non-temporal Medium DC Input, Non-temporal, Low FWR Input FWR Input, Temporal, High FWR Input, Temporal, Medium FWR Input, Temporal, Low FWR Input, Non-temporal, High FWR Input, Non-temporal, Medium FWR Input, Non-temporal, Low 30 16 - 33 Volts 75 95 2W 1W 1/2W 1/4W 85 82 79 76 110 115 137 132 132 141 133 131 147 144 143 152 145 144 79 69 66 91 75 68 90 80 77 100 85 79 107 97 93 116 102 96 176 157 154 176 163 156 194 182 179 201 187 182 212 201 198 221 207 201 218 210 207 229 216 210 136 129 129 142 134 132 155 152 151 161 155 154 88 78 76 103 85 80 97 88 86 112 95 90 112 103 101 126 110 105 168 160 160 181 166 161 190 184 184 203 189 184 210 202 194 221 208 202 218 206 201 229 216 211 Two-Wire Horn/Strobe, HIGH Candela Range (135 - 185 cd), UL Maximum Current Draw (mA RMS 16 - 33 Volts DC Input 135 150 177 185 FWR Input 135 16 - 33 Volts 150 177 185 DC, Temporal High DC, Temporal Medium DC, Temporal Low DC, Non-temporal, High DC, Non-temporal, Medium DC, Non-temporal, Low 215 209 207 233 219 214 231 224 221 248 232 229 265 258 256 281 267 262 245 235 232 255 242 238 259 253 251 270 259 254 290 288 282 303 293 291 297 297 292 309 299 295 FWR, Temporal, High FWR, Temporal, Medium FWR, Temporal, Low FWR, Non-temporal, High FWR, Non-temporal, Medium FWR, Non-temporal, Low GAMEWELL-FCI 258 250 248 275 262 256 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60520 Rev. A page 3 of 5 Candela Derating Candela Derating (Continued) For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 15/75 Do not use below 32 F 30 75 44 95 70 Strobe Output (cd 110 115 135 150 177 185 Candela rating at –40°F 110 115 135 150 177 185 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 Switch Sound Volts Position Pattern dB DC FWR 1 Temporal High 78 78 2 Temporal Medium 74 74 3 Temporal Low 71 73 4 Non-Temporal High 82 82 5 Non-Temporal Medium 78 78 6 Non-Temporal Low 75 75 7‡ Coded High 82 82 8‡ Coded Medium 78 78 9‡ Coded Low 75 75 ‡Settings 7, 8 and 9 are not available on 2-wire horn strobe. 16-33 Volts DC 84 80 76 88 85 81 88 85 81 GAMEWELL-FCI FWR 84 80 76 88 85 81 88 85 81 24-Volt Nominal Reverberant DC FWR 88 88 86 86 83 80 93 92 90 90 88 84 93 92 90 90 88 85 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60520 Rev. A page 4 of 5 www.gamewell-fci.com Anechoic DC FWR 99 98 96 96 94 89 100 100 98 98 96 92 101 101 97 98 96 92 Ordering Information: Part Number Description Part Number Description WALL STROBES SW-ALERT SWH-ALERT SW-CLR-ALERT SR-P SRH-P CEILING HORN STROBE Strobe, Standard cd, White, Amber Lens PC2R-P Horn Strobe, Standard cd, Red, Clear Lens Strobe, High cd, White, Amber Lens PC2W-P Horn Strobe, Standard cd, White, Clear Lens Strobe, Standard cd, White, Clear Lens PC2WH-P Horn Strobe, High cd, White, Clear Lens Strobe, Standard cd, Red, Clear Lens WALL SPEAKER STROBE Strobe, High cd, Red, Clear Lens SPSW-ALERT Speaker Strobe, Standard cd, White, Amber Lens SW-P Strobe, Standard cd, White, Clear Lens SPSW-P Speaker Strobe, Standard cd, White, Clear Lens SWH-P Strobe, High cd, White, Clear Lens SPSR-P Speaker Strobe, Standard cd, Red, Clear Lens SRK-P Strobe, Standard cd, Red, Clear Lens, Out- SPSWH-P Speaker Strobe, High cd, White, Clear Lens door SRHK-P Strobe, High cd, Red, Clear Lens, Outdoor SPSRH-P Speaker Strobe, High cd, Red, Clear Lens SWK-P Strobe, Standard cd, White, Clear Lens, Out- SPSW-P Speaker Strobe, Standard cd, White, High door Volume, Clear Lens SWHK-P Strobe, High cd, White, Clear Lens, Outdoor SPSRV-P Speaker Strobe, Standard cd, Red, High Volume, Clear Lens CEILING STROBES SPSWK-P Speaker Strobe, Standard cd, White, Clear Lens, Outdoor SCW-CLR-ALERT Strobe, Standard cd, White, Clear Lens SPSRK-P Speaker Strobe, Standard cd, Red, Clear Lens, Outdoor SCW-P Strobe, Standard cd, White, Clear Lens WALL HORNS/STROBES CEILING SPEAKER STROBE P2R-P Horn Strobe, Standard cd, Red, Clear Lens SPSCW-CLRSpeaker Strobe, Standard cd, White, Clear ALERT Lens P2W-P Horn Strobe, Standard cd, White, Clear Lens SPSCW-P Speaker Strobe, Standard cd, White, Clear Lens P2WH-P Horn Strobe, High cd, White, Clear Lens SPSCWH-P Speaker Strobe, High cd, White, Clear Lens Speaker Strobe, High Volume, White, Clear P2RK-P Horn Strobe, Standard cd, Red, Clear Lens, SPSCWV-P Outdoor Lens P2RHK-P Horn Strobe, High cd, Red, Clear Lens, Out- SPSCWVH-P Speaker Strobe, High cd, High Volume, White, door Clear Lens P2WK-P Horn Strobe, Standard cd, White, Clear Lens, Outdoor P2WHK-P Horn Strobe, High cd, White, Clear Lens, Outdoor NOTE: All –P models have a plain housing (no “FIRE” marking on cover). All outdoor units with a “K” designation in the part number include a weatherproof back box. All “ALERT” models are printed as such. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60520 Rev. A page 5 of 5