Model RGH - Honeywell Test and Measurement Sensors

Model RGH
Rod End In-line Compression/Tension Load Cell
DESCRIPTION
The Model RGH In-Line load cells are high quality, stainless
cannot be completely controlled. The flexible mounting options
steel, rugged load cells capable of withstanding significant
make applications easier to implement, and the all stainless
off-axis loads, making them an ideal choice for in-line compres-
steel, hermetic construction is well suited to corrosive and very
sion measurement or tension measurement where side loading
high humidity environments.
FEATURES
•
2000 lb to 50000 lb range
•
Male/female threads
•
Stainless steel, all-welded construction
•
1 mV/V nominal (standard); 0 Vdc to 5 Vdc or 4 mA to 20
mA outputs (optional)
•
Compression/tension
•
0.25 % accuracy
• CE approved10
Model RGH
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range Code
Available ranges
Load ranges
2000, 3000, 4000, 5000, 10000, 15000,
25000, 50000 lb
DL
2000 lb
3000 lb
Accuracy
±0.25 % full scale1
DN
4000 lb
Linearity
±0.25 % full scale
DP
±0.25 % full scale
DR
5000 lb
Hysteresis
10000 lb
Non-repeatability
± 0.05 % full scale
DV
1 mV/V (nominal)
EJ
15000 lb
Output (tolerance)
25000 lb
Operation
Tension/compression
EM
Infinite
EP
50000 lb
Resolution
11
ENVIRONMENTAL SPECIFICATIONS
WIRING CODES
Connector
Unamplified (Std.)
Characteristic
Measure
A
(+) excitation
Temperature, operating
-54 °C to 121 °C [-65 °F to 250 °F]
B
(+) excitation
Temperature, compensated
15 °C to 71 °C [60 °F to 160 °F]
C
(-) excitation
Temperature effect, zero
0.005 % full scale/°F
D
(-) excitation
Temperature effect, span
0.005 % full scale/°F
E
(-) output
F
(+) output
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Bonded foil
Excitation (calibration)
10 Vdc
Excitation (acceptable)
Up to 15 Vdc or Vac
Insulation resistance
DEFLECTIONS AND RINGING FREQUENCIES
Capacity (lb)
Deflection at
full scale mm
[in]
Ringing frequency (Hz)
Weight kg
[lb]
5000 mOhm @ 50 Vdc
2000
0,025 [0.001]
10000
0,55 [1.2]
Bridge resistance (tolerance)
700 ohm
3000
0,025 [0.001]
12000
0,55 [1.2]
Shunt calibration data
Included
4000
0.038 [0.0015]
13000
0,59 [1.3]
Electrical termination (std)
PTIH-10-6P or equivalent (hermetic
stainless)
5000
0,050 [0.002]
15000
0,63 [1.4]
10000
0,050 [0.002]
10000
1,3 [2.9]
15000
0,050 [0.002]
10000
1,3 [2.9]
25000
0,050 [0.002]
6500
4,3 [9.5]
50000
0,076 [0.003]
7000
4,3 [9.5]
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Maximum allowable load
150 % FS1
Case material
Stainless steel
Life cycles (approx)
>10 million cycles
Deflection full scale
0,076 mm [0.003 in]
2 Honeywell • Sensing and Control
Rod End In-Line Compression/Tension Load Cell
INTERNAL AMPLIFIERS
Amplifier
specifications
Voltage output:
Option 2b
Voltage output:
Option 2c
Voltage output:
Option 2t
Current threewire: Option 2j
Current twowire: Option 2k
Intrinsically safe
amp: Option 2n
(2N)***
Output signal
±5 V
0 V to 5 V or ±5 V
@ 45 mA
0 V to 10 V or ±10
V @ 45 mA
4 mA to 20 mA
4 mA to 20 mA
4 mA to 20 mA
Input power
(voltage)
±15 V or 26 Vdc to
32 Vdc
11 Vdc to 28 Vdc
15 Vdc to 28 Vdc
22 Vdc to 32 Vdc
15 Vdc to 40 Vdc
9 Vdc to
28 Vdc
Input power
(current)
45 mA
40 mA
40 mA
65 mA
4 mA to 28 mA
4 mA to 24 mA
Freq. resp
(amp)
3000 Hz
3000 Hz
3000 Hz
2500 Hz
300 Hz
2000 Hz
Power supply
rej.
60 db
60 db
60 db
60 db
60 db
60 db
Operating
temp.
-20 °F to 185 °F
-20 °F to 185 °F
-20 °F to 185 °F
0 °F to 185 °F
0 °F to 185 °F
-20 °F to 185 °F
Reverse voltage protection
Yes
Yes
Yes
Yes
Yes
Yes
Short cir.
protection
Momentary
Momentary
Momentary
Yes
Yes
Yes
Wiring code:
connector
(std)4
A (+) Supply
B Output common
C Supply return
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return **
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
Wiring code:
cable4,5,6
R (+) Supply
Bl Output common
G Supply return
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl (+) Output
W Case ground
R (+) Supply
Bl (+) Output
W Case ground
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.
ALLOWABLE MAXIMUM LOADS2
Capacity (lb)
Side load (lb)
(% of load capacity)
Torque (lb-in)
(% of load capacity)
2000
20 %
20 %
3000
20 %
20 %
4000
20 %
20 %
5000
20 %
20 %
10000
20 %
20 %
15000
20 %
20 %
25000
20 %
20 %
50000
20 %
20 %
Honeywell • Sensing and Control 3
Model RGH
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges
2K, 3K, 4K, 5K, 10K, 15K, 25K, 50K lb
Temperature
compensation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
1g. 70 °F to 325 °F8
1h. 70 °F to 400 °F8
1i. -65 °F to 250 °F8
1j. 0 °C to 50 °C
1k. -20 °C to 85 °C
1m. -25 °C to 110 °C
Internal
amplifiers
2u. Unamplified, mV/V output
2b. 4 wire, ±5 Vdc output
2c. 0 Vdc to 5 Vdc
2j. 4 mA to 20 mA (three-wire) output
2k. 4 mA to 20 mA (two-wire)13
2t. 0 Vdc to 10 Vdc output
Internal amp
enhancements
3a. Input/output isolation7
3d. Remote buffered shunt calibration
Electrical
termination
6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F)
(ranges 50000 lb and below)
6b. MS connector MS3102E-14S-6P (mates with MS3106E14S-6), (max. 160 °F) (ranges above 50000 lb)6
6e. Integral cable: Teflon
6f. Integral cable: PVC
Shunt
calibration
8a. Precision internal resistor8
Bridge type
11a. Square bridge8
11b. Symmetrical bridge8
11c. Square and symmetrical bridge8
31a. Dual bridge
Bridge
resistance
12b. 5000 ohm (foil) (max. 250 °F)
Zero and
span
adjustment
14a. No access to zero and span adjustment
Electrical
connector
orientation
15a. Horizontal electrical exit port orientation
15b. Vertical electrical exit port orientation
15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and
vibration
44a. Shock and vibration resistance
Interfaces
53e. Signature calibration8
53t. TEDS IEEE 1451.4 module9
4 Honeywell • Sensing and Control
6g. Integral cable: Neoprene
6h. Integral cable: Silicone
6i. Integral underwater cable
6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6q. Integral cable: Polyurethane
6v. Phoenix connector on end of cable
Rod End In-Line Compression/Tension Load Cell
MOUNTING DIMENSIONS
Unamplified only
Amplified only
Range (lb)
D mm [in]
T
L2 mm [in]
L1 mm [in]
A mm [in]
B mm [in]
E mm [in]
F mm [in]
2000 to 5000
44,45 [1.75]
3/4-16 UNF
24,13 [0.95]
66,80 [2.63]
19,05 [0.75]
20,82 [0.82]
49,53 [1.95]
38,1 [1.50]
10000 to 15000
63,5 [2.50]
1 1/2-12 UNF
44,45 [1.75]
114,3 [4.50]
19,05 [0.75]
20,82 [0.82]
49,53 [1.95]
38,1 [1.50]
25000 to 50000
88,9 [3.50]
2-12 UNF
57,15 [2.25]
146,05 [5.75]
19,05 [0.75]
20,82 [0.82]
49,53 [1.95]
38,1 [1.50]
TYPICAL SYSTEM DIAGRAM
Honeywell • Sensing and Control 5
Model RGH
Rod End In-Line Compression/Tension Load Cell
NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9. 10.
11.
12.
Allowable maximum loads – maximum load to be applied without
damage.2
Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire
units) or 80 % (voltage amplified units) of full scale output for quick
calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown;
W=White; G=Green. Color specifying cable and number or letter
specifying connector.
No mating connector necessary for cable option.
Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i.
Only available with option 2b or 2c.
Not available with amplified option.
Consult factory for TEDS availability with amplified models.
Termination dependent; consult factory.
This unit calibrated to Imperial (non-Metric) units.
5000 ohm bridge required.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives
and distributors. For application
assistance, current specifica-
•The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
[email protected]
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
008658-2-EN IL50 GLO January 2010
Copyright © 2010 Honeywell International Inc. All rights reserved.