Model RGH Rod End In-line Compression/Tension Load Cell DESCRIPTION The Model RGH In-Line load cells are high quality, stainless cannot be completely controlled. The flexible mounting options steel, rugged load cells capable of withstanding significant make applications easier to implement, and the all stainless off-axis loads, making them an ideal choice for in-line compres- steel, hermetic construction is well suited to corrosive and very sion measurement or tension measurement where side loading high humidity environments. FEATURES • 2000 lb to 50000 lb range • Male/female threads • Stainless steel, all-welded construction • 1 mV/V nominal (standard); 0 Vdc to 5 Vdc or 4 mA to 20 mA outputs (optional) • Compression/tension • 0.25 % accuracy • CE approved10 Model RGH PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Load ranges 2000, 3000, 4000, 5000, 10000, 15000, 25000, 50000 lb DL 2000 lb 3000 lb Accuracy ±0.25 % full scale1 DN 4000 lb Linearity ±0.25 % full scale DP ±0.25 % full scale DR 5000 lb Hysteresis 10000 lb Non-repeatability ± 0.05 % full scale DV 1 mV/V (nominal) EJ 15000 lb Output (tolerance) 25000 lb Operation Tension/compression EM Infinite EP 50000 lb Resolution 11 ENVIRONMENTAL SPECIFICATIONS WIRING CODES Connector Unamplified (Std.) Characteristic Measure A (+) excitation Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] B (+) excitation Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] C (-) excitation Temperature effect, zero 0.005 % full scale/°F D (-) excitation Temperature effect, span 0.005 % full scale/°F E (-) output F (+) output ELECTRICAL SPECIFICATIONS Characteristic Measure Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance DEFLECTIONS AND RINGING FREQUENCIES Capacity (lb) Deflection at full scale mm [in] Ringing frequency (Hz) Weight kg [lb] 5000 mOhm @ 50 Vdc 2000 0,025 [0.001] 10000 0,55 [1.2] Bridge resistance (tolerance) 700 ohm 3000 0,025 [0.001] 12000 0,55 [1.2] Shunt calibration data Included 4000 0.038 [0.0015] 13000 0,59 [1.3] Electrical termination (std) PTIH-10-6P or equivalent (hermetic stainless) 5000 0,050 [0.002] 15000 0,63 [1.4] 10000 0,050 [0.002] 10000 1,3 [2.9] 15000 0,050 [0.002] 10000 1,3 [2.9] 25000 0,050 [0.002] 6500 4,3 [9.5] 50000 0,076 [0.003] 7000 4,3 [9.5] MECHANICAL SPECIFICATIONS Characteristic Measure Maximum allowable load 150 % FS1 Case material Stainless steel Life cycles (approx) >10 million cycles Deflection full scale 0,076 mm [0.003 in] 2 Honeywell • Sensing and Control Rod End In-Line Compression/Tension Load Cell INTERNAL AMPLIFIERS Amplifier specifications Voltage output: Option 2b Voltage output: Option 2c Voltage output: Option 2t Current threewire: Option 2j Current twowire: Option 2k Intrinsically safe amp: Option 2n (2N)*** Output signal ±5 V 0 V to 5 V or ±5 V @ 45 mA 0 V to 10 V or ±10 V @ 45 mA 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA Input power (voltage) ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F Reverse voltage protection Yes Yes Yes Yes Yes Yes Short cir. protection Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std)4 A (+) Supply B Output common C Supply return D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B Output common** C Supply return ** D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B Output common** C Supply return** D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B Output common** C Supply return** D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B No connection C No connection D (+) Output E Case ground F No connection A (+) Supply B No connection C No connection D (+) Output E Case ground F No connection Wiring code: cable4,5,6 R (+) Supply Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl (+) Output W Case ground R (+) Supply Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00. ALLOWABLE MAXIMUM LOADS2 Capacity (lb) Side load (lb) (% of load capacity) Torque (lb-in) (% of load capacity) 2000 20 % 20 % 3000 20 % 20 % 4000 20 % 20 % 5000 20 % 20 % 10000 20 % 20 % 15000 20 % 20 % 25000 20 % 20 % 50000 20 % 20 % Honeywell • Sensing and Control 3 Model RGH OPTION CODES Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http:// sensing.honeywell.com/TMsensor-ship for updated listings. Load ranges 2K, 3K, 4K, 5K, 10K, 15K, 25K, 50K lb Temperature compensation 1a. 60 °F to 160 °F 1b. 30 °F to 130 °F 1c. 0 °F to 185 °F 1d. -20 °F to 130 °F 1e. -20 °F to 200 °F 1f. 70 °F to 250 °F 1g. 70 °F to 325 °F8 1h. 70 °F to 400 °F8 1i. -65 °F to 250 °F8 1j. 0 °C to 50 °C 1k. -20 °C to 85 °C 1m. -25 °C to 110 °C Internal amplifiers 2u. Unamplified, mV/V output 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 mA to 20 mA (three-wire) output 2k. 4 mA to 20 mA (two-wire)13 2t. 0 Vdc to 10 Vdc output Internal amp enhancements 3a. Input/output isolation7 3d. Remote buffered shunt calibration Electrical termination 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F) (ranges 50000 lb and below) 6b. MS connector MS3102E-14S-6P (mates with MS3106E14S-6), (max. 160 °F) (ranges above 50000 lb)6 6e. Integral cable: Teflon 6f. Integral cable: PVC Shunt calibration 8a. Precision internal resistor8 Bridge type 11a. Square bridge8 11b. Symmetrical bridge8 11c. Square and symmetrical bridge8 31a. Dual bridge Bridge resistance 12b. 5000 ohm (foil) (max. 250 °F) Zero and span adjustment 14a. No access to zero and span adjustment Electrical connector orientation 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration8 53t. TEDS IEEE 1451.4 module9 4 Honeywell • Sensing and Control 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Integral cable: Polyurethane 6v. Phoenix connector on end of cable Rod End In-Line Compression/Tension Load Cell MOUNTING DIMENSIONS Unamplified only Amplified only Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in] 2000 to 5000 44,45 [1.75] 3/4-16 UNF 24,13 [0.95] 66,80 [2.63] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] 10000 to 15000 63,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 114,3 [4.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] 25000 to 50000 88,9 [3.50] 2-12 UNF 57,15 [2.25] 146,05 [5.75] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] TYPICAL SYSTEM DIAGRAM Honeywell • Sensing and Control 5 Model RGH Rod End In-Line Compression/Tension Load Cell NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Allowable maximum loads – maximum load to be applied without damage.2 Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. No mating connector necessary for cable option. Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i. Only available with option 2b or 2c. Not available with amplified option. Consult factory for TEDS availability with amplified models. Termination dependent; consult factory. This unit calibrated to Imperial (non-Metric) units. 5000 ohm bridge required. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifica- •The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. tions, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell’s test and measurement products, call +1-614-850-5000, visit www.honeywell.com/sensotec, or e-mail inquiries to [email protected] Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 008658-2-EN IL50 GLO January 2010 Copyright © 2010 Honeywell International Inc. All rights reserved.