Model LM Gage Pressure Transducer DESCRIPTION The Model LM pressure transducer is a cost efficient general gas and liquid pressure overloads of up to 50% over capacity purpose gage-only device. Each unit is constructed of welded are safely accepted. stainless steel for durability in dry rugged environments. Both FEATURES • 1 psig to 10000 psig range • Integral cable connection • 1/4-18 NPT female pressure port • mV/V output • 0.5 % accuracy Model LM PERFORMANCE SPECIFICATIONS Characteristic Measure Accuracy ±0.5 % full scale 1 ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F] Temperature effect, zero 0.01 % full scale/°F Temperature effect, span 0.02 % reading/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Excitation (calibration) 10 Vdc Excitation (acceptable) 10 Vdc Insulation resistance 5000 mOhm @ 50 Vdc Electrical termination (std) Cable 0.91 m [3 ft] OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Pressure ranges 1, 2.5, 5, 15, 25, 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10000 psig Temperature compensation 1a. 60 °F to 160 °F Internal amplifiers 2u. Unamplified, mV/V output Pressure ports 5a. 1/4-18 NPT female Electrical termination Cable 0.91 m [3 ft] Special calibration 9a. 10 point (5 up/5 down) @ 20 % increments 9b. 20 point (10 up/10 down) @ 10 % increments WIRING CODES MECHANICAL SPECIFICATIONS Cable Unamplified Red (+) Excitation Characteristic Measure Black (-) Excitation Media All gases/liquids compatible with wetted parts Green (-) Output Overload, safe 50 % over capacity White (+) Output Pressure port 1/4-18 NPT female Wetted parts Stainless steel Weight 170 g [6 oz] Case material Stainless steel 2 Honeywell • Sensing and Control Gage Pressure Transducer 1000 10000 750 7500 500 5000 300 3000 200 2000 150 20 K 100 20 K 75 DV 50 DT 30 DR 15 DN 5 DL 2.5 DJ 1 Pressure range (psig) 1500 RANGE CODES RANGE CODE AP AS AT BJ BM BN BP BR CJ CL CP CR CT CV L mm [in] 57,4 [2.26] 56,6 [2.23] 51 [2.00] 45 [1.78] Hex mm [in] psia 25,4 [1.0] 25,4 [1.0] 22,2 [0.875] 19 [0.75] Over pressure (test) (psi) 4 10 20 50 100 150 150 150 150 % full scale Over pressure (burst) (psi) Consult factory 600 800 1.2 K 2K 2K 4K 6K 8K 12 K 15 K Natural frequency (Hz) Consult factory 9.8 K 11 K 14 K 18 K 22 K 30 K 48 K 54 K 66 K 85 K Port volume mm3 [in3] 2,5 [0.15] 2,8 [0.17] Output (mV/V) 5 Wetted parts 316 stainless steel 17-4 PH stainless steel Bridge resistance 5000 ohm 350 ohm Strain gage type Silicon Foil 10 Mounting dimensions and characteristics >100 K 3,1 [0.12] 2 TYPICAL SYSTEM DIAGRAM For reference only Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Honeywell • Sensing and Control 3 Model LM NOTES Gage Pressure Transducer 1. Accuracies stated are expected for best-fit straight line for all errors including linearity, hysteresis & non-repeatability thru zero. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to [email protected] WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008702-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved.