Model LM - Honeywell Test and Measurement Sensors

Model LM
Gage Pressure Transducer
DESCRIPTION
The Model LM pressure transducer is a cost efficient general
gas and liquid pressure overloads of up to 50% over capacity
purpose gage-only device. Each unit is constructed of welded
are safely accepted.
stainless steel for durability in dry rugged environments. Both
FEATURES
•
1 psig to 10000 psig range
•
Integral cable connection
•
1/4-18 NPT female pressure port
•
mV/V output
•
0.5 % accuracy
Model LM
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Accuracy
±0.5 % full scale
1
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated
16 °C to 71 °C [60 °F to 160 °F]
Temperature effect, zero
0.01 % full scale/°F
Temperature effect, span
0.02 % reading/°F
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Excitation (calibration)
10 Vdc
Excitation (acceptable)
10 Vdc
Insulation resistance
5000 mOhm @ 50 Vdc
Electrical termination (std)
Cable 0.91 m [3 ft]
OPTION CODES
Range Code
Many range/option combinations are available in
our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Pressure ranges
1, 2.5, 5, 15, 25, 50, 75, 100, 150, 200, 300,
500, 750, 1000, 1500, 2000, 3000, 5000, 7500,
10000 psig
Temperature
compensation
1a. 60 °F to 160 °F
Internal
amplifiers
2u. Unamplified, mV/V output
Pressure ports
5a. 1/4-18 NPT female
Electrical
termination
Cable 0.91 m [3 ft]
Special
calibration
9a. 10 point (5 up/5 down) @ 20 % increments
9b. 20 point (10 up/10 down) @ 10 % increments
WIRING CODES
MECHANICAL SPECIFICATIONS
Cable
Unamplified
Red
(+) Excitation
Characteristic
Measure
Black
(-) Excitation
Media
All gases/liquids compatible with wetted
parts
Green
(-) Output
Overload, safe
50 % over capacity
White
(+) Output
Pressure port
1/4-18 NPT female
Wetted parts
Stainless steel
Weight
170 g [6 oz]
Case material
Stainless steel
2 Honeywell • Sensing and Control
Gage Pressure Transducer
1000
10000
750
7500
500
5000
300
3000
200
2000
150
20
K
100
20
K
75
DV
50
DT
30
DR
15
DN
5
DL
2.5
DJ
1
Pressure range
(psig)
1500
RANGE CODES
RANGE CODE
AP
AS
AT
BJ
BM BN
BP
BR
CJ
CL
CP
CR
CT
CV
L mm [in]
57,4 [2.26]
56,6 [2.23]
51 [2.00]
45 [1.78]
Hex mm [in] psia
25,4 [1.0]
25,4 [1.0]
22,2 [0.875]
19 [0.75]
Over pressure
(test) (psi)
4
10
20
50
100
150
150
150
150 % full scale
Over pressure
(burst) (psi)
Consult factory
600
800
1.2
K
2K
2K
4K
6K
8K
12
K
15
K
Natural frequency
(Hz)
Consult factory
9.8
K
11
K
14
K
18
K
22
K
30
K
48
K
54
K
66
K
85
K
Port volume
mm3 [in3]
2,5 [0.15]
2,8 [0.17]
Output (mV/V)
5
Wetted parts
316 stainless steel
17-4 PH stainless steel
Bridge
resistance
5000 ohm
350 ohm
Strain gage type
Silicon
Foil
10
Mounting dimensions and characteristics
>100 K
3,1 [0.12]
2
TYPICAL SYSTEM DIAGRAM
For reference only
Special requirements (consult factory)
Have a special requirement? New case pressure, different cable lengths,
electrical connectors, or materials? Consult our factory by calling +1
614-850-5000 (800-848-6564). Customization is key to our test and
measurement business. Special outputs, wiring codes, and calibrations
are all standard to us.
Honeywell • Sensing and Control 3
Model LM
NOTES
Gage Pressure Transducer
1. Accuracies stated are expected for best-fit straight line for all errors
including linearity, hysteresis & non-repeatability thru zero.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to [email protected]
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008702-1-EN IL50 GLO May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.