Model HP High Pressure Transducer DESCRIPTION The high pressure transducer Model HP is designed to accept the pressure element rupture. These transducers operate in a extreme pressure ranges of 50000 psi to 100,000 psi. Equipped wide temperature range from -65 °F through 250 °F. Temperature with a special safety blow out plug in its outer case, this trans- effects on span and zero are 0.005 % each and a full scale ac- ducer will allow the excess pressure to gradually leak out should curacy of 0.5 % is achieved. FEATURES • 50000 psi to 100000 psi • AE F-250-C port • 0.5 % accuracy • mV/V, 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc to 10 Vdc output • Intrinsically safe available (2N option only)10 • CE approved11 Model HP PERFORMANCE SPECIFICATIONS Characteristic Measure Accuracy ±0.50 % full scale Resolution Infinite Calibration Output 2 OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensorship for updated listings. 5 point calibration: 0 %, 50 %, and 100 % of full scale Pressure ranges 50000, 75000, 10000016 psi 1 mV/V Temperature compensation 1a. 60 °F to 160 °F 1b. 30 °F to 130 °F 1c. 0 °F to 185 °F 1d. -20 °F to 130 °F 1e. -20 °F to 200 °F 1f. 70 °F to 250 °F 1g. 70 °F to 325 °F 1i. -65 °F to 250 °F Internal amplifiers 2u. Unamp., mV/V output 2a. 0 Vdc to 5 Vdc (four wire) output14 2c. 0 Vdc to 5 Vdc output14 2j. 4 mA to 20 mA (three wire) output14 2k. 4 mA to 20 mA (two wire) output13,14 2n. (2N) 4 mA to 20 mA (two-wire), intrinsically safe13,14 2t. 0 Vdc to 10 Vdc output14 Internal amplifier enhancements 3a. Input/output isolation12 3d. Remote buffered shunt calibration Pressure ports 5u. 9/16-18 UNF female per Autoclave F-250-C Electrical termination7 6a. Bendix PTIH-10-6P (or equivalent), 6 pin (max 250 °F) 6e. Integral cable: Teflon (-65 °F to 475 °F) 6f. Integral cable: PVC (-20 °F to 160 °F) 6g. Integral cable: Neoprene (0 °F to 185 °F) 6h. Integral cable: Silicone (-65 °F to 300 °F) 6i. Integral underwater cable (max 180 °F) Shunt calibration 8a. Precision internal resistor8 Special calibration 9a. 10 point (5 up/5 down) 20 % increments @ 60 °F Bridge type 11a. Square bridge15 11b. Symmetrical bridge15 11c. Square and symmetrical bridge15 Bridge resistance 12b. 5000 ohm (foil) (max 250 °F) Zero and span adjustment 14a. No access to pots 14b. Top access to pots Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration8 53t. TEDS IEEE1451.4 module9 ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature compensated 15 °C to 71 °C [60 °F to 160 °F] Temperature effect, zero 0.005 % full scale/°F Temperature effect, span 0.005 % reading/°F Temperature effect, sealing Hermetically sealed IP68/NEMA 6P ELECTRICAL SPECIFICATIONS Characteristic Measure Strained gage type Bonded foil Insulation resistance 5000 mOhm @ 50 Vdc Bridge resistance 350 ohm Shunt calibration data Included Electrical termination (std) PTIH-10-6P or equivalent (Hermetic stainless) Mating connector (not incl) PT06A-10-6S or equiv. (AA111) MECHANICAL SPECIFICATIONS Characteristic Measure Media All gases and liquids compatible with wetted parts Wetted parts material 15-5 PH stainless steel Weight 12 oz Case material 304 Stainless steel Marking Permanent metal name plate MILSTD130F 4.3; Individual sequential serial number per sensor; Country of origin and date of manufacture WIRING CODES Connector Unamplified A&B (+) Excitation C&D (-) Excitation E (-) Output F (+) Output 2 Honeywell • Sensing and Control High Pressure Transducer Range CODES Pressure range (psi) 50000 75000 1000001 Range code EP ER ET D mm [in] 38,1 [1.50] L mm [in] 74,17 [2.92] L* mm [in] 110,49 [4.35] Over pressure (test) psi 75000 100000 100000 Over pressure (burst) psi 100000 125000 140000 Port volume in 0.015 Natural frequency (Hz) Greater than 100 kHz Installation torque (ft-lb/N-m) 25/34 30/41 35/47 3 *Length of pressure transducer with amplified option (see option codes) Mounting dimensions and characteristics TYPICAL SYSTEM DIAGRAM For reference only Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Honeywell • Sensing and Control 3 Model HP NOTES High Pressure Transducer 1. For pressure ranges 75000 psi or above, consult factory for pressure port information. 2. Accuracies stated are expected for best-fit straight line for all errors, including linearity, hysteresis & non-repeatability thru zero. 3. Input power (voltage) for internal amplifier options 2j, 2k, 2n (2N) depends on load resistance. 4. CE mark requires options 6a & 3d. 5. Interconnecting shunt cal. 1 with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire units), or 80 % (voltage amp. units) of full scale output for quick calibration. 6. G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow; R=Red; O=Orange. Color specifying cable and number or letter specifying connector. 7. No mating connector necessary with cable option. 8. Cannot be used with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. Range dependent; consult factory. 11. Termination dependent; consult factory. 12. Input/output isolation only available with voltage output (2A or 2C amplifiers). 13. 5000 ohm bridge required. 14. Not available with temperature below -29 °C [-20 °F] or above 85 °C [185 °F]. 15. Not available with amplified options. 16. Not available with 2n(2N) option. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to [email protected] WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008703-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved.