DESCRIPTION
The high pressure transducer Model HP is designed to accept
the pressure element rupture. These transducers operate in a
extreme pressure ranges of 50000 psi to 100,000 psi. Equipped
wide temperature range from -65 °F through 250 °F. Temperature
with a special safety blow out plug in its outer case, this trans-
effects on span and zero are 0.005 % each and a full scale ac-
ducer will allow the excess pressure to gradually leak out should
curacy of 0.5 % is achieved.
FEATURES
•
50000 psi to 100000 psi
•
AE F-250-C port
•
0.5 % accuracy
•
mV/V, 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc to 10 Vdc
output
•
Intrinsically safe available (2N option only)10
•
CE approved11
Model HP
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Accuracy
±0.50 % full scale
Resolution
Infinite
Calibration
Output
2
OPTION CODES
Range Code
Many range/option combinations are available in our
quick-ship and fast-track manufacture programs.
Please see http://sensing.honeywell.com/TMsensorship for updated listings.
5 point calibration: 0 %, 50 %, and
100 % of full scale
Pressure
ranges
50000, 75000, 10000016 psi
1 mV/V
Temperature
compensation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
1g. 70 °F to 325 °F
1i. -65 °F to 250 °F
Internal amplifiers
2u. Unamp., mV/V
output
2a. 0 Vdc to 5 Vdc
(four wire) output14
2c. 0 Vdc to 5 Vdc
output14
2j. 4 mA to 20 mA
(three wire) output14
2k. 4 mA to 20 mA (two
wire) output13,14
2n. (2N) 4 mA to 20 mA
(two-wire), intrinsically
safe13,14
2t. 0 Vdc to 10 Vdc
output14
Internal
amplifier enhancements
3a. Input/output isolation12
3d. Remote buffered shunt calibration
Pressure
ports
5u. 9/16-18 UNF female per Autoclave F-250-C
Electrical
termination7
6a. Bendix PTIH-10-6P (or equivalent), 6 pin (max
250 °F)
6e. Integral cable: Teflon (-65 °F to 475 °F)
6f. Integral cable: PVC (-20 °F to 160 °F)
6g. Integral cable: Neoprene (0 °F to 185 °F)
6h. Integral cable: Silicone (-65 °F to 300 °F)
6i. Integral underwater cable (max 180 °F)
Shunt calibration
8a. Precision internal resistor8
Special calibration
9a. 10 point (5 up/5 down) 20 % increments @
60 °F
Bridge type
11a. Square bridge15
11b. Symmetrical bridge15
11c. Square and symmetrical bridge15
Bridge resistance
12b. 5000 ohm (foil) (max 250 °F)
Zero and
span
adjustment
14a. No access to pots
14b. Top access to pots
Shock and
vibration
44a. Shock and vibration resistance
Interfaces
53e. Signature calibration8
53t. TEDS IEEE1451.4 module9
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature compensated
15 °C to 71 °C [60 °F to 160 °F]
Temperature effect, zero
0.005 % full scale/°F
Temperature effect, span
0.005 % reading/°F
Temperature effect, sealing
Hermetically sealed IP68/NEMA 6P
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strained gage type
Bonded foil
Insulation resistance
5000 mOhm @ 50 Vdc
Bridge resistance
350 ohm
Shunt calibration data
Included
Electrical termination (std)
PTIH-10-6P or equivalent (Hermetic
stainless)
Mating connector (not incl)
PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Media
All gases and liquids compatible with
wetted parts
Wetted parts material
15-5 PH stainless steel
Weight
12 oz
Case material
304 Stainless steel
Marking
Permanent metal name plate MILSTD130F 4.3; Individual sequential
serial number per sensor; Country of
origin and date of manufacture
WIRING CODES
Connector
Unamplified
A&B
(+) Excitation
C&D
(-) Excitation
E
(-) Output
F
(+) Output
2 Honeywell • Sensing and Control
High Pressure Transducer
Range CODES
Pressure range (psi)
50000
75000
1000001
Range code
EP
ER
ET
D mm [in]
38,1 [1.50]
L mm [in]
74,17 [2.92]
L* mm [in]
110,49 [4.35]
Over pressure (test) psi
75000
100000
100000
Over pressure (burst) psi
100000
125000
140000
Port volume in
0.015
Natural frequency (Hz)
Greater than 100 kHz
Installation torque (ft-lb/N-m)
25/34
30/41
35/47
3
*Length of pressure transducer with amplified option (see option codes)
Mounting dimensions and characteristics
TYPICAL SYSTEM DIAGRAM
For reference only
Special requirements (consult factory)
Have a special requirement? New case pressure, different cable lengths,
electrical connectors, or materials? Consult our factory by calling +1
614-850-5000 (800-848-6564). Customization is key to our test and
measurement business. Special outputs, wiring codes, and calibrations
are all standard to us.
Honeywell • Sensing and Control 3
Model HP
NOTES
High Pressure Transducer
1. For pressure ranges 75000 psi or above, consult factory for pressure port information.
2. Accuracies stated are expected for best-fit straight line for all errors, including linearity, hysteresis & non-repeatability thru zero.
3. Input power (voltage) for internal amplifier options 2j, 2k, 2n (2N)
depends on load resistance.
4. CE mark requires options 6a & 3d.
5. Interconnecting shunt cal. 1 with shunt cal. 2 terminal provides 50
% (unamplified units), 75 % (4 mA to 20 mA three-wire units), or 80
% (voltage amp. units) of full scale output for quick calibration. 6. G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow;
R=Red; O=Orange. Color specifying cable and number or letter
specifying connector.
7. No mating connector necessary with cable option.
8. Cannot be used with amplified option.
9. Consult factory for TEDS availability with amplified models.
10. Range dependent; consult factory.
11. Termination dependent; consult factory.
12. Input/output isolation only available with voltage output (2A or 2C
amplifiers).
13. 5000 ohm bridge required.
14. Not available with temperature below -29 °C [-20 °F] or above
85 °C [185 °F].
15. Not available with amplified options.
16. Not available with 2n(2N) option.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to [email protected]
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing