Specification AXON20 Oscillator type: PLXO - Phase-Locked

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 2
Date: 2014-06-20
AXON20
PLXO - Phase-Locked Crystal Oscillator – Low Phase Noise
Parameter
Reference frequency (input) fREF
Output frequency fOUT
Frequency stability (free running)
vs. operating temperature range
vs. supply voltage variation (pushing)
vs. load change (pulling)
Long term (aging) per year
Reference input
Frequency accuracy
Signal waveform
Input level
Input impedance
Input capacitance
Frequency locking
Frequency locking range
VCXO Control Voltage (VC) output
Lock detect (LD) output
Loop filter parameters
Natural loop frequency fN
Phase margin ΦR
Channel spacing fCH
Lock-in time
RF output (locked)
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Suppression of channel spurious
Other non-harmonic spurious
Phase noise
Supply voltage VS
Current consumption
Operating temperature range
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
4.
min.
typ.
max.
Unit
Condition
100
160
MHz
MHz
Note 2
±10
±2
±2
±2
ppm
ppm
ppm
ppm
VS ±5%
Load ±10%
@ +40°C
±2
Sine or square wave
0.5
VS
10
10
ppm
5
80
Lock on fREF under worst
conditions over 10 years
0.15
3.00
LD = High PLL locked
LD = Low PLL out of lock
Note 3
Note 3
Note 3
Note 3
3.15
-20
V
RIN = 470 kΩ
HCMOS levels
Hz
°
kHz
s
HCMOS
15
5
60
40
-80
-100
Vp-p
kΩ
pF
Consult factory
3.3
3.45
50
+70
20.0x13.1x6.1 max.
3
Tape & Reel
pF
ns
%
dBc
dBc
±10%
@ VS/2
@ N·fCH and fOUT ± N·fCH
V
mA
°C
Note 4
mm
g
IEC 61837-4 CO 29
IEC 60286-3
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Internal Low Phase Noise VCXO
To be optimized to application w.r.t to phase noise and settling performance. Please consult factory
5V supply voltage on request
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXON20 Rev.2
Drawing D0
Page 1(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Absolute Maximum Ratings
Parameter
min.
max.
Unit
Condition
Supply Voltage VS
Reference Input Level
Storage Temperature
-0.5
-40
VS + 10%
VS + 10%
+85
V
Vp-p
°C
VS to GND
Ordering Code
Model
Input Frequency [MHz]
Output Frequency [MHz] Revision
AXON20
5 to 100
Example: AXON20-5.000-100.000_Rev.2
80 to 160
Rev.2
Enclosure drawing
Pin connections:
Pin #
1
2
6
7
8
9
13
14
Symbol
VC
LD
GND
GND
RF OUT
GND
FREF
VS
Function
VCXO Control Voltage Output
Lock Detect Output
Ground
Ground
RF Output
Ground
Reference Frequency Input
Supply Voltage
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXON20 Rev.2
Drawing D0
Page 2(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Handling and Testing
Parameter
Procedure
Handling and Testing
Processing
Source
Application Note AXAN-011
Application Note AXAN-012
Parameter
Procedure
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
IEC60749-26
IEC60749-27
Yes
Yes
www.axtal.com
www.axtal.com
Condition
HBM
MM
No
No
2000 V
200 V
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
1
1
1
2
D0
D1
D2
D0
13.08.2008
28.03.2011
01.10.2012
20.06.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
First issue
Max. output frequency increased to 160 MHz
Minor editorial changes
Various parameters updated,
environmental conditions updated, editorial changes
AXON20 Rev.2
Drawing D0
Page 3(3)
Author
Checked
BN
HH
BN
HH
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]