Recommended Reflow Profile
A PCBA reflow profile depends
on the thermal mass of the
entire populated board. The
actual temperature used in
the reflow oven is a function
of:
Solder paste types
Board density
Component location
Component mass
Board finish
Temperature
–
–
–
–
–
1
®
Innovasic Product Reflow Profiles
Extended Life Semiconductor Solutions
Profile
Preheat and soak
Min. temperature (Tsmin)
Max. temperature (Tsmax)
Time (tsmin to tsmax) (ts)
Sn-Pb Eutectic Assembly
Pb-Free Assembly
100°C
150°C
60 ~ 120 seconds
150°C
200°C
60 ~ 120 seconds
Average ramp-up rate
(Tsmax to Tp)
3°C/second (Max.)
3°C/second (Max.)
Liquid temperature (TL)
Time at liquid (tL)
183°C
60 ~ 150 seconds
217°C
60 ~ 150 seconds
Peak package body
temperature (Tp)*
Please refer to the classification temperature IPC/JEDEC J-STD-020D at
http://www.smta.org/files/JSTD020D-01.pdf.
Time (tp)** within 5°C of the
specified classification
temperature (Tc)
20** seconds
30** seconds
Average ramp-down rate
(Tp to Tsmax)
6°C/second (Max.)
6°C/second (Max.)
Time to peak temperature
from 25°C
6 minutes (Max.)
8 minutes (Max.)
* Tolerance for peak profile temperature (Tp) is defined as a supplier minimum and a user maximum.
** Tolerance for time at peak profile temperature (tp) is defined as a supplier minimum and a user maximum.
Note 1: All temperatures refer to the center of the package, measured on the package body surface that is facing up during assembly reflow (e.g.,
live-bug). If parts are reflowed in other than the normal live-bug assembly reflow orientation (i.e., dead-bug), Tp shall be within ±2°C of the
live-bug Tp and still meet the Tc requirements, otherwise, the profile shall be adjusted to achieve the latter. To accurately measure actual
peak package body temperatures, please refer to JEP140 for recommended thermocouple use.
Note 2: All components in the test load shall meet the classification profile requirements.
Note 3: SMD packages classified to a given moisture sensitivity level by using Procedures or Criteria defined within any previous version of
J-STD-020, JESD22-A112 (Rescinded), IPC-SM-786 (Rescinded) do not need to be reclassified to the current revision unless a change in
classification level or a higher peak classification temperature is desired.