EF-1277-6B

EF-1277-6D
This filter was designed for use with the Vicor HAM
m odule a nd als o pr o v id es the s am e f r equenc y
attenuation as the HH-1055-6.3
LINE
LOAD
There is an additional MOV across the input to the filter
in order to provide the recommended transient protection
for the HAM module.
BROWN
T his pack aging pr ovides another option for the
mechanical designer and frees space on the board.
BLUE
Other options are also available and our engineering
department is always willing to help with design
modifications.
Order P/N:
G/Y
EF-1277-6D
Operating Voltage: ____________________ 85 to 250 V
Operating Current: _______________________6.0 Amp
Operating Frequency: ____________________50/60 Hz
Operating Temperature: ________________ -20 to 50°C
INSERTION LOSS vs. FREQUENCY
Diel. Withstanding (line - case): ____________1500 Vac
Diel. Withstanding (line - line): _____________1500 Vdc
Leakage Current: __________1.0 mA @ 220 Vac; 50 Hz
Max Residual Voltage after 1 sec: ___________ 34 Volts
Calculated MTBF: _________2,430,895 Hrs @ 30°C GB
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK