EF-1277-6D This filter was designed for use with the Vicor HAM m odule a nd als o pr o v id es the s am e f r equenc y attenuation as the HH-1055-6.3 LINE LOAD There is an additional MOV across the input to the filter in order to provide the recommended transient protection for the HAM module. BROWN T his pack aging pr ovides another option for the mechanical designer and frees space on the board. BLUE Other options are also available and our engineering department is always willing to help with design modifications. Order P/N: G/Y EF-1277-6D Operating Voltage: ____________________ 85 to 250 V Operating Current: _______________________6.0 Amp Operating Frequency: ____________________50/60 Hz Operating Temperature: ________________ -20 to 50°C INSERTION LOSS vs. FREQUENCY Diel. Withstanding (line - case): ____________1500 Vac Diel. Withstanding (line - line): _____________1500 Vdc Leakage Current: __________1.0 mA @ 220 Vac; 50 Hz Max Residual Voltage after 1 sec: ___________ 34 Volts Calculated MTBF: _________2,430,895 Hrs @ 30°C GB USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK