AA-1355-6.3HT

AA-1355-6.3HT
The AA-1355-6.3HT filter has been designed to operate
with the VICOR Harmonic Attenuator Module (HAM).
This filter was specifically designed to allow the Vicor
HAM and ass oc iated power conver ters to m eet
Mil-Std-461D, E or F
This version of the filter is configured for those
applications where a chassis mount for the filter is
preferred.
Order P/N:
AA-1355-6.3HT
Operating Voltage = ___________________ 85 to 250 V
Operating Current = ______________________6.3 Amp
Operating Frequency = __________________50/400 Hz
Operating Temperature, High = _______________ 60º C
Operating Temperature, Low = _______________-40º C
INSERTION LOSS vs. FREQUENCY
Diel. withstanding (line - case)____1500 Vac
Diel. withstanding (line - line)_____1500 Vdc
Leakage Current = ___________2.5 ma @ 220 V, 60 Hz
Max residual voltage after 1 sec = ________ __ 34 Volts
Calculated MTBF = ________2,142,107 Hrs @ 30°C GB
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK