JMK HH-1355-6.3

HH-1355-6.3 Series
JMK Inc
The HH-1355-6.3C filter has been designed to operate with the
VICOR Harmonic Attenuator Module (HAM). This filter was
specifically designed to allow the Vicor HAM and associated
power converters to meet Mil-Std-461C or Mil-Std-461D & E.
The enclosure mounting, and pin configuration are identical to
the enclosure for the standard HAM filter.
It will be necessary to add transient protection across the output of the filter to protect the HAM module. It is recommended
that you use 5%, bipolar TVS diodes. 2 x 130V and 1 x 150V
diodes connected in series.
The HAM will meet Mil-Std-461C with the HH-1355-6.3 with
voltage inputs of 125 or 250 Vac.
It will also meet Mil-Std-461D,E, or F with a 125 volt input.
Additional circuitry is required on the input in order to meet
Mil-Std-461D, E, & F if 250 volts is the input voltage.
The additional circuitry is shown on the schematic.
4-40 INSERT
.25 DP (4 PL)
.080 DIA PIN (6 PL)
4.60
0.25
0.94
2.50
LINE
2.40 2.00
0.20
USA
LOAD
0.30
0.50
1.46
1.80
0.50
2.80
0.06
0.13 ±0.02
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
Operating voltage________________85 to 250 V~
Operating current ________________6.3 Amp
Operating frequency______________50/400 Hz
Operating temperature, High________See temp.curve
Operating temperature, Low ________-20º C, Std
________ -40º C, HT & BHT
________ _55º C, CHT
Diel. withstanding (line - case)_______1500 Vac
Diel. withstanding (line - line)________1500 Vdc
Leakage current__________________2.5 ma @ 220 V, 60 Hz
Max residual voltage after 1 sec__ 34 Volts
The filter is available in both the standard model and three
wider temperature range models.
The temperature ranges at full load are listed below:
HH-1355-6.3_______(-20—40º C)
HH-1355-6.3HT_____(-40—55º C)
HH-1355-6.3BHT___ (-40—70º C)
HH-1355-6.3CHT___ (-55—70º C)
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]