MD100S-xxER Datasheet

MD100SER Series
Low Cost, 1W SIP
Tightly Regulated
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
Input
Parameter
Conditions
• Tight Regulation
• Miniature SIP Case
Input Voltage Range
• 1,000 VDC Isolation
• 23 Single Output Models
Input Filter
• >3.5 MHour MTBF
Output
• -40°C to +85°C Operation
Parameter
• LOW COST
Output Voltage Accuracy
Min.
Typ.
Max.
5 VDC Input
4.75
5.0
5.25
12 VDC Input
11.40
12.0
12.60
15 VDC Input
14.25
15.0
15.75
24 VDC Input
22.80
24.0
25.20
Typ.
Max.
Units
VDC
Internal Capacitor
Conditions
Line Regulation
Min.
For VIN Min to Max
For IOUT = 10% to 100%
Load Regulation
Ripple (20 MHz)
10
Noise (20 MHz)
See Note 2
50
Temperature Coefficient
Output Short Circuit
Units
±3.0
%
±0.25
%
±1.0
%
20
mV P - P
75
mV P - P
±0.03
%/°C
12 VDC & 15 VDC Input Models
Continuous (Autorecovery)
5 VDC and 24 VDC Input Models
Momentary (1.0 Sec)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,000
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
Max.
Units
VDC
M
60
pF
100
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Min.
Typ.
Max.
-40
+25
+85
°C
+125
°C
95
%
-55
Cooling
Units
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
0.772 x 0.236 x 0.394 Inches (19.6 x 6.0 x 10.0 mm)
Case Material
MicroPower Direct
Non-Conductive Black Plastic (UL-94V0)
Weight
0.07 Oz (2.1g)
292 Page Street
Suite D
Stoughton, MA 02072
USA
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Parameter
Conditions
MTBF
Min.
MIL HDBK 217F, 25°C, Gnd Benign
Typ.
Max.
3.5
Units
MHours
Absolute Maximum Ratings
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
15 VDC Input
-0.7
21.0
24 VDC Input
-0.7
30.0
1.5 mm From Case For 10 Sec
300
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Voltage (VDC)
Current (mA)
Voltage Current
(mA, Max)
Nominal
Range
Full-Load No-Load (VDC)
5
4.75 - 5.25
220
30
5.0
150
5
4.75 - 5.25
294
30
5.0
200
5
4.75 - 5.25
285
30
9.0
111
5
4.75 - 5.25
281
30
12.0
83
5
4.75 - 5.25
274
30
15.0
67
5
4.75 - 5.25
294
30
24.0
42
12
11.4 - 12.6
89
15
5.0
150
12
11.4 - 12.6
124
15
5.0
200
12
11.4 - 12.6
116
15
9.0
111
12
11.4 - 12.6
119
15
12.0
83
12
11.4 - 12.6
113
15
15.0
67
12
11.4 - 12.6
122
15
24.0
42
15
14.25 - 15.75
74
12
5.0
150
15
14.25 - 15.75
99
12
5.0
200
15
14.25 - 15.75
94
12
9.0
111
15
14.25 - 15.75
94
12
12.0
83
15
14.25 - 15.75
98
12
24.0
42
24
22.8 - 25.2
46
8
5.0
150
24
22.8 - 25.2
61
8
5.0
200
24
22.8 - 25.2
61
8
9.0
111
24
22.8 - 25.2
57
8
12.0
83
24
22.8 - 25.2
56
8
15.0
67
24
22.8 - 25.2
61
8
24.0
42
MD0705S-05ER
MD105S-05ER
MD105S-09ER
MD105S-12ER
MD105S-15ER
MD105S-24ER
MD0712S-05ER
MD112S-05ER
MD112S-09ER
MD112S-12ER
MD112S-15ER
MD112S-24ER
MD0715S-05ER
MD115S-05ER
MD115S-09ER
MD115S-12ER
MD115S-24ER
MD0724S-05ER
MD124S-05ER
MD124S-09ER
MD124S-12ER
MD124S-15ER
MD124S-24ER
Notes:
1. Operation at no load will not damage these units. However, they may not meet all specifications.
2. These converters will operate without external components. However, when measuring output ripple, it is
recommended that an external ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units. An input capacitor will enhance stability
over temperature and input line variations. For applications requiring very low output noise levels, a simple
LC filter, as shown in the connection diagram below, should be effective. Recommended component values are
given in the table below the diagram.
VIN
C1
L1
VOUT
L2
C2
5 VDC
12 VDC
15 VDC
24 VDC
4.7 µF/50V
4.7 µF/50V
2.2 µF/50V
1.0 µF/50V
4.7 - 10 µH
4.7 - 10 µH
4.7 - 10 µH
4.7 - 10 µH
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
4.7 - 10 µH
4.7 - 10 µH
4.7 - 10 µH
4.7 - 10 µH
4.7 - 10 µH
10 µF
4.7 µF
2.2 µF
1.0 µF
0.47 µF
Current
(mA, Min)
15.0
20.0
12.0
9.0
7.0
5.0
15.0
20.0
12.0
9.0
7.0
5.0
15.0
20.0
12.0
9.0
5.0
15.0
20.0
12.0
9.0
7.0
5.0
Fuse Rating
Slow-Blow
Efficiency
(%, Typ)
(mA)
68
66
70
71
73
68
70
67
72
70
74
68
68
67
71
71
68
68
68
68
73
75
68
500
600
600
600
600
600
200
250
250
250
250
250
150
200
200
200
200
100
125
125
125
125
125
Derating Curve
Mechanical Dimensions
3. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
Function
1
+VIN
2
-VIN
4
-VOUT
6
+VOUT
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the unit
FAX: (781) 344-8481
•
E-Mail: [email protected]