MD100SER Series Low Cost, 1W SIP Tightly Regulated DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 1W Output Power Input Parameter Conditions • Tight Regulation • Miniature SIP Case Input Voltage Range • 1,000 VDC Isolation • 23 Single Output Models Input Filter • >3.5 MHour MTBF Output • -40°C to +85°C Operation Parameter • LOW COST Output Voltage Accuracy Min. Typ. Max. 5 VDC Input 4.75 5.0 5.25 12 VDC Input 11.40 12.0 12.60 15 VDC Input 14.25 15.0 15.75 24 VDC Input 22.80 24.0 25.20 Typ. Max. Units VDC Internal Capacitor Conditions Line Regulation Min. For VIN Min to Max For IOUT = 10% to 100% Load Regulation Ripple (20 MHz) 10 Noise (20 MHz) See Note 2 50 Temperature Coefficient Output Short Circuit Units ±3.0 % ±0.25 % ±1.0 % 20 mV P - P 75 mV P - P ±0.03 %/°C 12 VDC & 15 VDC Input Models Continuous (Autorecovery) 5 VDC and 24 VDC Input Models Momentary (1.0 Sec) General Parameter Conditions Isolation Voltage Isolation Resistance Isolation Capacitance Min. 60 Seconds 1,000 500 VDC 1,000 100 kHz, 1V Switching Frequency Typ. Max. Units VDC M 60 pF 100 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Storage Temperature Range Min. Typ. Max. -40 +25 +85 °C +125 °C 95 % -55 Cooling Units Free Air Convection Humidity RH, Non-condensing Physical Case Size 0.772 x 0.236 x 0.394 Inches (19.6 x 6.0 x 10.0 mm) Case Material MicroPower Direct Non-Conductive Black Plastic (UL-94V0) Weight 0.07 Oz (2.1g) 292 Page Street Suite D Stoughton, MA 02072 USA Reliability Specifications T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Parameter Conditions MTBF Min. MIL HDBK 217F, 25°C, Gnd Benign Typ. Max. 3.5 Units MHours Absolute Maximum Ratings Conditions Input Voltage Surge (1 Sec) Lead Temperature Min. Typ. Max. 5 VDC Input -0.7 9.0 12 VDC Input -0.7 18.0 15 VDC Input -0.7 21.0 24 VDC Input -0.7 30.0 1.5 mm From Case For 10 Sec 300 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number Output Voltage (VDC) Current (mA) Voltage Current (mA, Max) Nominal Range Full-Load No-Load (VDC) 5 4.75 - 5.25 220 30 5.0 150 5 4.75 - 5.25 294 30 5.0 200 5 4.75 - 5.25 285 30 9.0 111 5 4.75 - 5.25 281 30 12.0 83 5 4.75 - 5.25 274 30 15.0 67 5 4.75 - 5.25 294 30 24.0 42 12 11.4 - 12.6 89 15 5.0 150 12 11.4 - 12.6 124 15 5.0 200 12 11.4 - 12.6 116 15 9.0 111 12 11.4 - 12.6 119 15 12.0 83 12 11.4 - 12.6 113 15 15.0 67 12 11.4 - 12.6 122 15 24.0 42 15 14.25 - 15.75 74 12 5.0 150 15 14.25 - 15.75 99 12 5.0 200 15 14.25 - 15.75 94 12 9.0 111 15 14.25 - 15.75 94 12 12.0 83 15 14.25 - 15.75 98 12 24.0 42 24 22.8 - 25.2 46 8 5.0 150 24 22.8 - 25.2 61 8 5.0 200 24 22.8 - 25.2 61 8 9.0 111 24 22.8 - 25.2 57 8 12.0 83 24 22.8 - 25.2 56 8 15.0 67 24 22.8 - 25.2 61 8 24.0 42 MD0705S-05ER MD105S-05ER MD105S-09ER MD105S-12ER MD105S-15ER MD105S-24ER MD0712S-05ER MD112S-05ER MD112S-09ER MD112S-12ER MD112S-15ER MD112S-24ER MD0715S-05ER MD115S-05ER MD115S-09ER MD115S-12ER MD115S-24ER MD0724S-05ER MD124S-05ER MD124S-09ER MD124S-12ER MD124S-15ER MD124S-24ER Notes: 1. Operation at no load will not damage these units. However, they may not meet all specifications. 2. These converters will operate without external components. However, when measuring output ripple, it is recommended that an external ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. An input capacitor will enhance stability over temperature and input line variations. For applications requiring very low output noise levels, a simple LC filter, as shown in the connection diagram below, should be effective. Recommended component values are given in the table below the diagram. VIN C1 L1 VOUT L2 C2 5 VDC 12 VDC 15 VDC 24 VDC 4.7 µF/50V 4.7 µF/50V 2.2 µF/50V 1.0 µF/50V 4.7 - 10 µH 4.7 - 10 µH 4.7 - 10 µH 4.7 - 10 µH 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC 4.7 - 10 µH 4.7 - 10 µH 4.7 - 10 µH 4.7 - 10 µH 4.7 - 10 µH 10 µF 4.7 µF 2.2 µF 1.0 µF 0.47 µF Current (mA, Min) 15.0 20.0 12.0 9.0 7.0 5.0 15.0 20.0 12.0 9.0 7.0 5.0 15.0 20.0 12.0 9.0 5.0 15.0 20.0 12.0 9.0 7.0 5.0 Fuse Rating Slow-Blow Efficiency (%, Typ) (mA) 68 66 70 71 73 68 70 67 72 70 74 68 68 67 71 71 68 68 68 68 73 75 68 500 600 600 600 600 600 200 250 250 250 250 250 150 200 200 200 200 100 125 125 125 125 125 Derating Curve Mechanical Dimensions 3. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Function 1 +VIN 2 -VIN 4 -VOUT 6 +VOUT MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Pin 1 is marked by a “dot” or indentation on the unit FAX: (781) 344-8481 • E-Mail: [email protected]