MPD MPM-20S-12

MPM-20S Series
Universal Input, 20W
Miniature, PC Mount
AC/DC Power Supplies
Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 20W Output Power
Parameter
• Universal 85-264 VAC Input
Input Voltage Range
• EN 60950 Approved
• Adjustable Output
• Meets EN55022 B
• >200 kHour MTBF
• Compact PC Mount Case
Conditions
Input Frequency
Input Current
Inrush Current
EMI
Safety Ground Leakage Current
Min.
Typ.
85
120
47
See Model Selection Guide
115 VAC
16.0
230 VAC
30.0
Meets CISPR Pub. 22/FCC Class B
115 VAC
230 VAC
Max.
264
370
63
Units
VAC
VDC
Hz
A Pk
0.1
0.3
mA
Max.
Units
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
±2.0
±0.5
See Model Selection Guide
50
115 VAC
20
230 VAC
80
±0.02
Continuous (Autorecovery)
Typ. 110% of Output Power
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
%
mV Pk - Pk
mSec
%/°C
General
Parameter
Conditions
Input to Output
Input to Ground
Output to Ground
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Isolation Voltage
EMI/RFI
EMC Compliance
Switching Frequency
Min.
3,000
1,500
500
Typ.
Max.
Units
VAC
EN 55022 Level B
IEC/EN 61000-4-2 Level 3
IEC/EN61000-4-3
IEC/EN 61000-4-4 Level 3 2 kV
IEC/EN 61000-4-5 Level 3 1kV/2 kV
150
kHz
Environmental
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Max.
+70
+90
-25
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
85
Ambient
Case
Min.
-25
Typ.
+25
Units
°C
°C
°C
%
2.75 x 1.88 x 0.92 Inches (70.0 x 48.0 x 23.5 mm)
Non-Conductive Black Plastic (UL94-V0)
5.65 Oz (160g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
200
IEN 60950, IEC 60950
IEN 60950, IEC 60950
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
Input
Current (A)
Voltage
115 VAC
230 VAC
(VDC)
0.33
0.33
0.33
0.33
0.33
0.18
0.18
0.18
0.18
0.18
3.3
5.0
12.0
15.0
24.0
MPM-20S-03
MPM-20S-05
MPM-20S-12
MPM-20S-15
MPM-20S-24
Output 1 (Vout 1)
Current (A)
Load
Typ.
Reg.
4.10
±1.0%
3.50
±1.0%
1.60
±1.0%
1.30
±1.0%
0.85
±1.0%
Over Volt.
Protection
Efficiency
(%, Typ)
(VDC)
6.5
6.5
20.0
20.0
30.0
82
82
82
82
82
Derating Curve
Dual & Triple Output Models Are Available.
For more information, contact the factory:
[email protected]
Notes:
1. Load regulation is measured for an output change of 10% to 90% at nominal input
line. For multiple output models, the loads are balanced.
2. As shown in the connection diagram at right, a simple external circuit may be used to
adjust the power supply output ±10%. To adjust the output DOWN, connect a 5%, 3W resistor
between the plus output pin and the Vout trim pin. To adjust the output UP, connect a 5%, 3W
resistor between the minus output pin and the Vout trim. Contact the factory for resistor values
needed to achieve a specific output.
3. It is recommended that a fuse be used on the input of a power supply for protection.
For the MPM-20S series, a 3.15A/250 VAC slow blow should be used.
Mechanical Dimensions
Typical Connection
Typical Component Values
Vout
3.3
5.0
12.0
15.0
24.0
Pin
Connections
Pin
Function
1
2
3
4
8
Trim
AC-Ground
AC-Neutral
AC-Line
-Vout
+Vout
Trim
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
C1
330 µF/16V
330 µF/16V
220 µF/25V
220 µF/25V
220 µF/35V
C2
Fuse
0.01 µF/25V
3.15A/
250 VAC
TVS
P6KE6.8A
P6KE6.8A
P6KE16A
P6KE20A
P6KE33A
Notes:
1. C1 is a high frequency, low resistance electrolytic capacitor. Refer to the suppliers specifications
for capacitance/current ratings.
2. Voltage derating on all capacitors should be 80% or higher.
3. C2 eliminates high frequency noise.
4. The power supply includes an internal TVS. If the user requires a tighter OVP threshold, an external
TVS may be connected as shown.
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]