MPM-40E Series Low Cost, Encapsulated Single Output, 40W AC/DC Power Supplies Key Features: Electrical Specifications • 40W Output Power • Universal 85-264 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Industry Standard Pin-Out • Meets EN 55022 Class B • >200 kHour MTBF • Low Cost Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 30.0 230 VAC 50.0 Max. 264 370 440 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide Max. Units 0.5 W % % % mV P-P Input Voltage Range Input Frequency Input Current Inrush Current Units VAC VDC Hz A Pk Output Parameter Output Voltage Output Current Standby Power Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) ±2.0 VIN = Min to Max ±0.5 See Note 2 ±1.0 50 115 VAC 15 230 VAC 80 ±0.02 Continuous (Autorecovery) Zener Diode Clamp Autorecovery 110 Hold-Up Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection 100 mSec %/°C %W General Parameter Isolation Voltage Isolation Resistance EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFMF Voltage Dips Switching Frequency Conditions 60 Sec 500 VDC Standard See Note 4 EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Min. 3,000 100 Typ. Min. Typ. Min. -40 Typ. +25 Max. Units VAC M Max. Units Class B Class B Criteria B; ±8 kV Air/±6 kV Contact Criteria A; 10V/m Criteria B; ±2 kV Criteria B; ±1 kV/ ±2 kV Criteria A; 10 Vrms Criteria A; 10A/m Criteria B; 95% 5000 mS 65 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Max. +70 +90 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Case Units °C °C °C % Physical Case Size Case Material Weight 3.50 x 2.50 x 0.984 Inches (89.0 x 63.5 x 25.0 mm) Non-Conductive Black Plastic (UL94-V0) 8.8 Oz (250g) Reliability Specifications Parameter MTBF Safety Standards Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 200 EN 60950 IEC 61140 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-40S-03E MPM-40S-05E MPM-40S-09E MPM-40S-12E MPM-40S-15E MPM-40S-24E Current (A) 115 VAC 230 VAC 0.860 0.460 0.860 0.460 0.860 0.460 0.860 0.460 0.860 0.460 0.860 0.460 Typical Connection Output Capacitive Efficiency Load Voltage Current Current (%, Typ) (µF Max.) (VDC) (A Max.) (% Min.) 3.3 5.0 9.0 12.0 15.0 24.0 8.000 8.000 4.444 3.333 2.666 1.666 10 10 10 10 10 10 60,000 40,000 7,200 9,000 6,600 2,000 78 82 84 84 84 84 Notes: 1. Operation at no load will not damage the units, however, they may not meet all specifications. 2. Load regulation is measured for an output change of 10% to 100% at nominal input line. 3. All units are rated for EN 55022 (CE/RE) class B without external components. 4. All units are rated for EN 61000-4-4 (±2 kV) and EN 61000-4-5 (±1k/±2 kV) without external components. They will meet EN 61000-4-5 (±2 kV/ ±4 kV) with additional input filtering as shown below. 5. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-40S-xxE series, a 3.15A/250 VAC slow blow should be used. The diagram below illustrates a typical application connection of the MPM-40S-xxE series. Notes on this circuit (starting with the input circuit) are: 1. It is recommended that an external fuse and NTC be used. The recommended fuse is a 3.15A/250V slow blow and for the NTC, a 5D-9. 2. An external MOV is required on the input to protect the unit in the event of a surge. A 561KD20 or equivalent is recommended. 3. Recommended output filtering capacitors are: C1 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V MPM-40S-03E MPM-40S-05E MPM-40S-09E MPM-40S-12E MPM-40S-15E MPM-40S-24E Typical Board Layout: With EMI Components (See note 4) C2 680 µF/10V 680 µF/10V 220 µF/25V 220 µF/25V 220 µF/25V 120 µF/35V TVS SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A The output filtering capacitor (C2) is a high frequency, low resistance electrolytic capacitor. Capacitor (C1) is ceramic. Voltage derating of capacitors should be 80% or above. 4. Input noise and surge suppression components are illustrated in the typical board layout at left. Modules are available for a number of MPD AC/DC power supplies that contain these components. For pricing or full technical information on these modules (ACFM-01 and ACFM-02) or suggested EMI circuits , please contact the factory. Pin Connections Derating Curve Pin Function Pin Function 1 2 3 AC-Line AC-Neutral +VOUT 5 7 -VOUT Trim Mechanical Dimensions Input Voltage Vs Load MicroPower Direct Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]