MPM-10PB Series Single Output, 10W Compact “Power Brick” AC/DC Power Supplies Key Features: • 10W Output Power • Universal 85-264 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Meets EN 55022 B • Meets ErP Directive • Industry Standard Pin-Out • >300 kHour MTBF Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 230 VAC Input Voltage Range Input Frequency Input Current Inrush Current No Load Power Consumption Max. 264 370 440 15.0 30.0 0.3 Units VAC VDC Hz A Pk W Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Conditions Min. Typ. See Model Selection Guide See Model Selection Guide Ripple & Noise (20 MHz), See Note 1 Hold-Up Time Temperature Coefficient Over Voltage Protection Over Temperature Protection Short Circuit Protection Overload Protection VIN = Min to Max IOUT = 10% to 100% 3.3V and 5V Models 12V, 15V, and 24V Models 115 VAC 230 VAC 1.5 0.8 20 60 ±0.01 Zener Diode Clamp 120 Autorecovery (at 67 °C) 90 Continuous (Autorecovery) Foldback, Autorecovery 105 Max. Units ±2.0 ±1.0 ±1.0 1.8 1.0 % % % ±0.02 % V P-P of VOUT mSec %/°C %VOUT °C %W General Parameter Isolation Voltage Isolation Resistance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFM Voltage Dips MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Conditions Input to Output 500 VDC Min. 3,000 100 Typ. Max. 125 Standard Min. EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Units VAC M kHz Typ. Max. Units Class B Class B Criteria B; ±8 kV Air/±4 kV Contact Criteria A; 10V/m Criteria B; ±2 kV Criteria B; ±1 kV Criteria B; 10 Vrms Criteria A; 30A/m Criteria B; 10 mS Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +70 -40 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 85 Ambient Units °C °C % Physical Case Size Case Material Weight 2.06 x 1.07 x 0.93 Inches (52.4 x 27.2 x 23.50 mm) Non-Conductive Black Plastic (UL94-V0) 1.90 Oz (54g) Reliability Specifications Parameter MTBF Safety Standards Safety Class ECO Design Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 EN 60950 IEC 60536 Class II ErP Directive 2009/125/EC www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-10S-03PB MPM-10S-05PB MPM-10S-12PB MPM-10S-15PB MPM-10S-24PB Current (A) 115 VAC 0.171 0.201 0.191 0.193 0.201 230 VAC 0.128 0.151 0.143 0.145 0.151 Notes: 1. Ripple and noise are measured at 20 Mhz bandwidth with a 0.1µF and a 47 µF capacitor connected in parallel as close to the unit output terminals as possible. 2. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 3. Operation at under no load conditions will not damage these units. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-10PB series, a 1.5A/250 VAC slow blow should be used. Output Voltage (VDC) 3.3 5.0 12.0 15.0 24.0 Maximum Capacitive Load Current Max. (A) 2.500 2.000 0.833 0.667 0.417 Min. (%) 10.0 10.0 10.0 10.0 10.0 Maximum Efficiency Output Power (%, Typ) (µF) 2,200 2,200 1,000 1,000 680 (W) 8.25 10.00 10.00 10.00 10.00 70 72 76 75 72 Derating Curve Mechanical Dimensions Pin Connections Pin 1 2 3 4 Function AC-Neutral AC-Line +Vout -Vout Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]