MDR-72S
Compact, 72W
DIN Rail Mount
AC/DC Power Supply
Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 72W Output Power
Parameter
• Compact, DIN Rail Case
Input Voltage Range
• 165-264 VAC Input
Input Frequency
Input Current
Inrush Current, See Note 1
Standby Power Consumption
• Low Standby Power
• TS-35/7.5 or TS-35/15 Rails
• Meets EN 55022 B
• High Efficiency
• >250 kHour MTBF
Conditions
Min.
Typ.
165
180
47
See Model Selection Guide
230 VAC
50
Max.
264
370
63
Units
VAC
VDC
Hz
0.5
A Pk
W
Max.
Units
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Output Voltage Adjust
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, See Note 3
Overload Protection, See Note 4
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
±3.0
±5.0
VIN = Min to Max
IOUT = 10% to 100%
±0.5
±2.0
150
230 VAC
60.0
±0.02
See Note 2
30
Continuous (Auto-Recovery)
Auto-Recovery 110
%
%
%
%
m V P-P
mS
%/°C
VDC
150
%IOUT
Max.
Units
General
Parameter
Conditions
Input to Output
Input to 
Output to 
Isolation Voltage, 60S
Isolation Resistance
Switching Frequency
EMI Characteristics, See Note 5
Parameter
Radiated Emissions
Conducted Emissions
ESD
MicroPower Direct
RS
EFT
Surge
CS
PFM
Voltage Dips, Interruptions
Min.
4,000
1,500
500
100
Typ.
VAC
M
kHz
100
Standard
Criteria
EN 55024
EN 55022
EN 61000-4-2
B
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
A
B
B
A
A
B
Level
Class B
Class B
±8 kV Air
±6 kV Contact
10V/m
±4 kV
±2 kV/ ±4 kV
10 Vrms
10A/m
0% - 70%
Environmental
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
Max.
-40
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
See Mechanical Diagram (Page 2)
Heat Resistant Plastic (UL94-V0) and Metal
11.53 Oz (340g)
Reliability Specifications
Parameter
MTBF
Safety Class
Conditions
Min.
MIL HDBK 217F, 25°C, Gnd Benign
250
Class I
Typ.
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
MDR-72S-24
Input
Current
(A Max)
Output
Voltage
Current (A)
Efficiency
(%, Typ)
230 VAC
(VDC)
Max.
Min.
1.0
24.0
3.0
0.3
86
Capacitive
Load
Fuse Rating
Slow-Blow
(µF Max)
(A/V)
2,000
3.15/250
Derating Curve, Temperature
Other outputs may be available
Contact the factory for details at:
[email protected]
Notes:
1. Inrush current is given for a cold start at 25°C.
2. Over voltage protection is provided by a zener diode clamp.
3. Output short circuit protection is provided by a “hiccup mode”
circuit. The unit recovers automatically when the fault condition is
removed.
4. Output overload protection is provided by a fold back current
limiting circuit with auto-recovery. A long-term overload could
damage the unit.
5. EMI characteristics are specified without external components.
6. Operation at no-load will not damage these units. However, they
may not meet all specifications.
7. The MDR-72S is designed for mounting on a standard 35 mm DIN
rail (TS35).
8. It is recommended that an external slow blow fuse also be used on
the input for protection. See the table above for the correct rating.
Derating Curve, Input Voltage
Mechanical Dimensions
Wire Connections
Pin
Function
1
2
3
4
5
6
7
+VOUT
+VOUT
-VOUT
-VOUT

AC-Neutral
AC-Line
Notes:
• All dimensions are typical in inches (mm)
• Wire Range is: 26 - 10 AWG, Strip length is 0.32 (8.0)
• Tolerance x.xx = ±0.02 (±0.5)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]