FlexTemp 2311 Universal Transmitter 4...20 mA transmitter RTD, T/C, mV and R inputs Isolation voltage 2 kVac Configuration via FlexProgrammer Accuracy better than 0.1°C (Pt100) Configurable linearisation, damping and status indication Local, remote or fixed compensation for "cold junction" (CJC) Description FlexTemp 2311 is a 4...20 mA loop-powered, configurable universal transmitter with galvanic isolation between input and output. The input can be configured for RTD or T/C sensors, resistance, current or voltage signals. Either 2-, 3- or 4-wire connection can be selected for the resistance input. The built-in temperature sensor or a remote Pt100 sensor can be used to compensate for "cold junction" (CJC) if thermocouples are connected. The configuration can be established from the dedicated FlexProgrammer configuring tool connected to a PC. www.baumerprocess.com Design and specifications subject to change without notice Data Sheet 2311-1 Page 1 Technical Data Input Environmental conditions Digital accuracy See „Measuring ranges“ Operating temperature -40...85°C CJC-compensation {1} Local < 0.7°C Storage temperature -55...90°C RTD measuring current 0.2 mA, continuously Humidity < 90% RH, non-condensing Vibrations Lloyds Register, test 2 Cable resistance 2-wire 3-/4-wire 3-/4-wire Max. 30 Ohm/wire {1} T > 600°C: Max. 10 Ohm/wire T < 600°C: Max. 30 Ohm/wire EMC data Generic standards EN 61000-6-3, EN61000-6-2 Protection +/- 35 Vdc Product standard EN 61326 Suppression 50 and 60 Hz Disposal of product and packing Resolution 16 bit According to national laws or by returning to Baumer Repeatability < 0.05°C Mechanical data Output Signal span 4...20 mA, 2-wire {1} 20...4 mA, 2-wire {1} Characteristic Linear or customised with max. 30 points {1} Dimensions 62 x 88 x 24 mm Protection class Housing: IP 30; Terminals: IP 10 Other data Isolation 50 Vac ; test 2 kVac Temperature drift Typ. 0.003% per °C Accuracy < 0.1% of signal span Supply range 6.5...35 Vdc Ripple immunity 3 Vrms Power-on time 1.8...3.9 sec. Load equation RL < (Vcc - 6.5)/23 [kOhm] Failure information NE43 Up/Down scaling limits 23 mA/3.5 mA {1} Test conditions Damping 0...30 sec. {1} Configuration Pt100; 0...100°C Response time (t90) Pt100 1.0 sec. ; T/C 1.6 sec. Amb. temperature 23°C +/- 2°C Resolution 12 bit Max. 0.01% per °C Note {1} Configurable {2} The max. temperature is lower for RTD-elements in the range 500...1000, i.e. Pt1000 max. 350°C. Measuring Ranges Type Pt25...Pt1000 Pt25...Pt1000 Pt25...Pt1000 Ni25...Ni1000 Cu25...Cu1000 B(PtRh30-Pt) E(NiCr-CuNi) J(Fe-CuNi) K(NiCr-Ni) L(Fe-CuNi) N(NiCrSi-NiSi) R(PtRh13-Pt) S(PtRh10-Pt) T(Cu-CuNi) U(Cu-CuNi) W5-Re (Type C) W3-Re (Type D) Lin. voltage Lin. voltage Lin. resistance Lin. resistance Standard DIN/EN/IEC 60751 a = 0.003902 a = 0.003916 DIN 43760 0.428 Ohm/°C IEC 584 IEC 584 IEC 584 IEC 584 DIN 43710 IEC 584 IEC 584 IEC 584 IEC 584 DIN 43710 ASTM 988 ASTM 988 www.baumerprocess.com Design and specifications subject to change without notice Range -200...850°C {2} -200...850°C {2} -200...850°C {2} -50...250°C {2} -50...200°C 100...1820°C -270...900°C -210...1200°C -250...1370°C -200...900°C -200...1300°C -50...1750°C -50...1750°C -250...400°C -200...600°C 0...2300°C 0...2300°C -10...70 mV -0.1...1.1 V 0...390 Ohm 0...2200 Ohm Min. span 10°C 10°C 10°C 10°C 10°C 50°C 50°C 50°C 50°C 50°C 50°C 100°C 100°C 40°C 50°C 100°C 100°C 2 mV 20 mV 5 Ohm 25 Ohm Accuracy 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 2°C 1°C 1°C 1°C 1°C 1°C 2°C 2°C 1°C 1°C 2°C 2°C 0.04 mV 0.4 mV 0.05 Ohm 0.25 Ohm Resolution 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1 mV 1 mV 0.01 Ohm 0.1 Ohm Data Sheet 2311-1 Page 2 Ordering Details - FlexTemp 2311 2311 000x (x) Type Standard version 5...8´ digit 1 Configuration Configuration according to customer specifications 9´ digit C Application Example 230 Vac Pt100 3 7 4 8 3 4 1 2 1 2 + 24 Vdc - 4...20 mA FlexTemp 2301 Power supply Configuration FlexProgrammer Note: Disconnect loop supply before connecting the FlexProgrammer to FlexTemp 2311. 1 FlexProgrammer 2 1 2 FlexProgrammer 9701 1 2 Red clip 1 2 Black clip Note: Ambient temperature range 0...50°C www.baumerprocess.com Design and specifications subject to change without notice Data Sheet 2311-1 Page 3 Electrical Installation 3 7 T/C 4 8 3 7 No cablecompensation {3} RTD 3 7 4 8 Internal CJCcompensation 3 7 RTD 4 8 4-wire cablecompensation Current measurement 4 8 4 8 3 7 No compensation {3} 3 7 + External CJC-compensation No cable compensation {3} 3 7 Resistance Resistance 4 8 3 7 3-wire compensation for transfer resistance {4} + External CJC-compensation 3-wire cable compensation Resistance 4 8 3 7 4-wire compensation for transfer resistance {4} Voltage measurement 4 8 3-wire cable compensation Potentiometer 3 7 4 8 No compensation {3} Potentiometer T/C 4 8 3 7 + T/C 3-wire cablecompensation 3 7 4 8 Potentiometer UK/2007-06-01 This data sheet may only be reproduced in full. RTD 4 8 4-wire cable compensation Notes {3} Configurable compensation for cable resistance {4} Transfer resistance between element and wiper 3 7 4 8 3 7 + 4 8 Dimensional drawings + [mm] Accessories 65.5 The FlexProgrammer 9701 is a dedicated tool to configure all Baumer configurable products. 88 62 24 Type No. 9701-0001 complies: FlexProgrammer interface unit CD with the FlexProgram software and product drivers (DTM) USB cable Cable with 2 alligator clips www.baumerprocess.com Design and specifications subject to change without notice Data Sheet 2311-1 Page 4