CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features Pt100 sensor element, 2- or 4-wire Built in graphical display, CombiViewTM DFON optional Head mounted 4...20 mA transmitter, FlexTop type 22xx HART®, PA ATEX EHEDG (pending) 3A, FDA Programmable by touch screen Easy and full programmable with FlexProgrammer 9701 Applications Food and beverage Pharmaceutical Water treatment General process industry Main characteristics (20 °C) Approvals Standard process temperature -50 … 250 °C Apply to Accuracy Pt100 output as to DIN/EN/IEN 60751 Transmitter output <±0.1 °C / <±0,25 °C EMC directive 2004/108/CE in accordance with EN 61000-6-2, EN 61000-6-3 Pressure directive 97/23/CE FDA Certificates Connections Technical specification Hygienic 3A EHEDG (pending) Measuring principle Resistance Temperature Detector (RTD) Measuring ranges -50...250 °C Immersion tube, diameter Immersion tube, length Immersion tube, tip Ø6 mm, Ø8 mm Min. 20 mm - Max. 3000 mm Normal response - Ø 6/Ø 8 mm Fast response - Ø 6/Ø 4 or Ø 8/Ø 4 mm Process connections See page 4 Temperature, Ambient -40…160 °C - w. transmitter -40…85 °C - w. display -30...80 °C Protection rating, IEC 529 IP67 / IP69K, depending on electrical connection With BattTemp : IP54 Humidity, IEC 68-2-38 98%, condensing Vibration IEC60068-2-6 DNV high vibration strain, class B 1.6 mm, 2...25 Hz IEC60068-2-6, test FC 25...100 Hz, 4.0 g Material Process connection S.S. 14404, AISI 316L Housing S.S. 14301, AISI 304 Sealing To be ordered separately see table page 4 Accuracy Class 1/1 B ±(0,3 + (0,005 x T)) °C Class 1/3 B ±1/3 x (0,3 + (0,005 x T)) °C Class 1/6 B ±1/6 x (0,3 + (0,005 x T)) °C Class 1/1 A ±(0,15 + (0,002 x T)) °C Analog output 4-20 mA, 4-20mA+HART®, rofibus® P See separate data sheet, series 22xx Time constant, τ 0,5 Medium Liquid Air Air Velocity 0,4 m/sec. 0 m/sec 3 m/sec ø 6mm <6,1 <138 <27,2 ø 6/4mm <1,5 <136 <21,4 ø 8mm <7,6 <201 <47,7 ø 8/4mm <1,5 <181 <33,6 Temperature curve Process °C 400 350 300 With cooling neck 250 Standard 200 150 100 85°C 50 0 www.baumer.com EN/2015-01-30 Environment RTD type Pt100 (acc. to DIN/EN/ IEC 60751) Single or Double 2-wire or 4-wire Design and specifications subject to change without notice Sensor element and electrical specification Sensor type 85°C 0 20 40 60 80 100 Ambient °C Data sheet TFRH Page 1 / 5 CombiTemp TFRH TM Hygienic – RTD temperature sensor Technical Data Transmitter, type FlexTop 2221 - Performance, HART® Transmitter, type FlexTop 2202 - Standard Input Pt100 Input Pt100 / Pt1000 (universal) Output Accuracy Input Output Range Minimum span 4...20 mA Output Accuracy Input Output 4...20 mA / HART Supply 8...35 VDC Range Minimum span -200...850°C 25°C Programmability By FlexProgrammer 9701 Supply 8...35 VDC Programmability By FlexProgrammer 9701 By HART terminal/modem <0.25°C <0.1% signal span (16mA) -200...850°C 25°C For further information please see data sheet for FlexTop 2202 <0.1°C <0.1% signal span (16mA) For further information please see data sheet for FlexTop 2221 Transmitter, type FlexTop 2211 - Performance Input Pt100 / Pt1000 (universal) Output Accuracy Input Output 4...20 mA Input Pt100 / Pt1000 (universal) <0.1°C <0.1% signal span (16mA) Profibus PA Range Minimum span -200...850°C 25°C Output Accuracy Input Supply 8...35 VDC Range Minimum span -200...850°C 25°C Programmability By FlexProgrammer 9701 Supply 9...32 VDC Programmability By FlexProgrammer 9701 For further information please see data sheet for FlexTop 2211 Display DFON Transmitter, type FlexTop 2231 - Performance, Profibus® <0.1°C For further information please see data sheet for FlexTop 2231 BattTemp Type Graphically LCD Front glass Polycarbonate Display modes 8 modes, programmable, e.g. value, bar graph, analogue, tank illustration Background Measuring range Type LCD Front glass Polycarbonate Temperature sensor Pt-100, 2-wire (DIN/EN/IEC 60751) White, green, red - programmable Power supply Battery 1,5 V, type AA -9999...99999 Range -200…850°C Digit height Max. 22 mm Measuring range -9999…9999 Accuracy 0,1% @ ambient -10…70 °C Unit °C Voltage drop 4V...6.5 V Output 2 configurable relay output, 60 Vp, 75 mA Digit height Touch screen or FlexProgrammer 9701 Further information can be found in separate data sheet for DFON, D21.09. Accuracy -200...-51°C +/- 0,6 +/- 1 digit -50...300°C +/- 0,3 +/- 1 digit 301...850°C +/- 0,6 +/- 1 digit For further information please see datasheet for BattTemp Design and specifications subject to change without notice Programming 11,5 mm. Electrical Electricalconnections connections M12, 8-wire Cable gland Transmitter 1 +24VDC / - 4...20mA 2 - 24VDC / +4...20mA 1 Red clip (FlexProgrammer) 2 Black clip (FlexProgrammer) 12 1 2 4...20 mA RTD 1+2 3+4 1 2 3 4 5 Single Double Pt100-1 Pt100-1 Pt100 – 1 Pt100 – 1 Pt100 – 2 Pt100 – 2 N.C. N.C. 11 22 33 44 55 supply,4...20 4...20mA mA +- supply, Commonfor forrelays relays Common supply, 4...20 mA - +supply, 4...20 mA Relay11 Relay Relay22 Relay 11 22 33 44 55 66 77 88 N.C. N.C. supply,4...20 4...20mA mA + -supply, Relay Relay1 1 Relay1 1 Relay Relay2 2 Relay Relay2 2 Relay + supply, 4...20 - supply, 4...20 mAmA N.C. N.C. RTD Single White White Red Red Double White White Red Red Display + 4...20 1 N.C. mA - 4...20 2 N.C. mA 3 Relay 1 4 Relay 1 5 Relay 2 6 Relay 2 Com 1 Red clip (FlexProgrammer) Com 2 Black clip (FlexProgrammer) EN/2015-01-30 M12, 5-wire Dimensions (mm) Front view www.baumer.com Bottom connection Rear connection Data sheet TFRH Page 2 / 5 CombiTemp TFRH TM Hygienic – RTD temperature sensor ATEX data for temperature transmitters and displays Transmitter, type FlexTop 2202 - ATEX Transmitter, type FlexTop 2221 - ATEX Approval Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Approval Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Supply 8...28 VDC Supply 8...30 VDC (Ex nA : 12...30 VDC) Internal inductivity Internal capacity Li ≤ 10 µH Ci ≤ 10 nF T1...T5: -40 <Tamb < 85°C T6: -40 <Tamb < 50°C Internal inductivity Internal capacity Li ≤ 15 µH Ci ≤ 5 nF T1...T5: -40 <Tamb < 85°C T6: -40 <Tamb < 50°C Barrier data U: ≤ 28 VDC I: ≤ 0.1A P: ≤ 0.75 W Approval Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Supply 6.5...30 VDC Internal inductivity Internal capacity Li ≤ 15 µH Ci ≤ 5 nF T1...T5: -40 <Tamb <85°C T6: -40 <Tamb <50°C Barrier data U: ≤ 30 VDC I: ≤ 0.1A P: ≤ 0.75 W Display DFON - ATEX ATEX Gas ia and for ATEX Dust ia Voltage drop UDisp Temperature class Li ≤ 1 5 µH Ci ≤ 5 nF Temperature class 4.5 ... 6.5 VDC T1...T5 Zone 0 and 20 -20 ... 60 °C Zone 1/2 and 21/22 -40 ... 65 °C Internal inductivity L i <10 µH Internal capacity C i <15 nF U i Ii Pi <30 VDC <0.1 A <0.75 W Barrier data U: ≤ 30 VDC I: ≤ 0.1A P: ≤ 0.75 W Approval Internal inductivity Internal capacity Temperature class Coupler/link FISCO approved Barrier data Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Li ≤ 10 µH Ci ≤ 2 nF T1...T4: -40 <Tamb < 85°C T5: -40 <Tamb < 60°C Ui ≤17.5 VDC Pi ≤0.75 W Li ≤10 µH Ii ≤ 0.275 A Ci ≤2nF Ui ≤20 VDC Pi ≤0.75 W Li ≤10 µH Ii ≤ 0.1 A Ci ≤ 2nF ATEX data for BattTemp II 1 G, Ex ia IIC T5 Ga II 1 D, Ex ia IIIC T100°C Da Approval Gas Zone 0/1 Dust Zone 20/21 Barrier data Transmitter, type FlexTop 2231 - ATEX Transmitter, type FlexTop 2211 - ATEX Temperature class Temperature class Approval Ex ia IIC T5/T6, ATEX II 1G Temperature class Battery : Energizer Lithium FR6 L91 AA T1…T4: -10<Tamb<70°C T5 : -10<Tamb<50°C Battery: Duracell Alkaline MN1500 LR6 AA T1…T3: -10<Tamb<70°C T4 : -10<Tamb<60°C Design and specifications subject to change without notice Temperature class ATEX Gas nA II 3 G, Ex nA II T5 Approval Gas Zone 2 Voltage drop UDisp Temperature class T1...T5 -30 < Tamb< 65 °C 4.5 ... 6.5 VDC Internal inductivity L i Internal capacity C i <15 nF Maximum voltage Umax <35 VDC Maximum current Umax<0.1A EN/2015-01-30 <10 µH www.baumer.com Data sheet TFRH Page 3 / 5 CombiTemp TFRH TM Hygienic – RTD temperature sensor Dimensions (mm) Ø80 mm housing front view Ø80 mm housing rear connection Ø80 mm housing bottom connection Ø55 mm housing 66 82 68 60 Ø91 91 95.5 Ø55 54 Ø22 Ø22 3A DN 38 Code 60 ISO 2852 DN 38 Code 65 ISO 2852 DN 51 Code 66 Variline® type N Code 70 25 Ø6 mm Ø8 mm Ø6 mm Ø8 mm Ø4 mm 17 mm Seal is to be purchased separately. For other types and materials please see data sheet for accessories. www.baumer.com Material Approvals Item Number O-ring 60 EPDM 3A FDA 8126982 - 70 EPDM 3A FDA 8126979 Gasket 65 EPDM 3A FDA 8126980 - 66 EPDM 3A FDA 8126981 Data sheet TFRH Page 4 / 5 EN/2015-01-30 L L L L L Accessories – seals Seal type Code Design and specifications subject to change without notice 16 25 G1/2A 32 65 NV 24 15 27 G½A Hygiene Code 51 CombiTemp TFRH TM Hygienic – RTD temperature sensor Ordering details – 5 6 7 1 3 5 B 9 0 1 3 0 1 2 4 6 0 1 2 3 4 5 0 1 3 9 0 1 2 3 0 1 2 5 6 7 8 A B 1 2 A B C D 0 4 51 60 65 66 70 0 1 2 1 2 0 x x x x EN/2015-01-30 If the product wanted is not available from above list please inquire. Design and specifications subject to change without notice Model CombiTempTM TFRH Housing material ø 80 mm, Stainless steel, AISI 304 Bottom ø 80 mm, Stainless steel, AISI 304 Rear Field housing Ø55, stainless steel, AISI 304 Electrical connection M12, 5 pins M12, 8 pins Cable gland, M16 Cable gland, M20 No electrical connection - for BattTemp only Material el. connection None - for BattTemp only Plastic AISI 304 Display Without display, Ø55 housing Without display With display No relays activated With display With activated relays With BattTemp Transmitter / socket Flying leads Ceramic socket Pt100 Transmitter 2202 4-20 mA ±0,25 °C (Accuracy class) Transmitter 2211 4-20 mA ±0,10 °C (Accuracy class) Transmitter 2221 4-20 mA / HART® ±0,10 °C (Accuracy class) Transmitter 2231 Profibus® ±0,10 °C (Accuracy class) Safety Standard Ex ia IIC T4/T5 1G (Gas) Ex nA II T4/T5 3G (Gas) Ex ia II 1 G Eex ia IIC, Zone 0, simple apparatus Configuration No configuration Configuration of Range Configuration of Range + Display Configuration of Range + Display incl. 2 x relays Sensor element (DIN/EN/IEC 60751) None (for cable sensor) 1x Pt100 Class 1/1 B 2x Pt100 Class 1/1 B 1x Pt100 Class 1/3 B 2x Pt100 Class 1/3 B 1x Pt100 Class 1/6 B 2x Pt100 Class 1/6 B 1x Pt100 Class 1/1 A 2x Pt100 Class 1/1 A Sensor insert type Sensor tube with embedded sensor element 2-wire Sensor tube with embedded sensor element 4-wire Cable sensor Pt100 Class 1/1 B (1xPt100 only, for ø 8 mm only) Cable sensor Pt100 Class 1/3 B (1xPt100 only, for ø 8 mm only) Cable sensor Pt100 Class 1/6 B (1xPt100 only, for ø 8 mm only) Cable sensor Pt100 Class 1/1 A (1xPt100 only, for ø 8 mm only) Cooling neck None Cooling neck Process connection G½ hygienic 3A DN38 Hygienic connection 3A DN25/DN38 Clamp ISO 2852, 1" - 1½" 3A DN51 Clamp ISO 2852, 2" 3A Variline® type N Gea Tuchenhagen Seal Without (to be ordered separately) Sensor diameter ø 6 mm AISI 316 ø 8 mm AISI 316 Sensor tip Standard Normal response Fast Fast response ø 4 mm tip Max sensor length : 300 mm Approvals None Sensor tube length Length in mm (min. 20 mm) www.baumer.com Data sheet TFRH Page 5 / 5