CombiTemp Temperature Measuring System Flexible building block concept All wetted parts in acid-proof, stainless steel Some hygienic connections conform to 3-A standards, FDA demands and EHEDG guidelines Flush mounted surface sensor ø80 mm stainless steel housing or DIN head, form B Pt100 or Pt1000 sensors, 2- or 4-wire DIN A or B (1/1, 1/3, 1/6) elements Standard or fast response time Display and 4...20 mA transmitter Cable sensors Standard and Ex versions Description CombiTemp comprises a series of basic elements which can be combined to various temperature sensors and transmitters. The system includes 4-wire Pt100 cable sensors. Being a building block system CombiTemp offers a great flexibility in respect to modification, service and maintenance. A wide range of process connections according to national and international standards, sensor elements and transmitters, can be selected to meet the actual requirements. CombiTemp is particularly suitable for use in food, beverage, pharmaceutical and chemical industries. A complete temperature sensor can be ordered on one type number. Please refer to CombiTemp Accessories data sheet for a comprehensive range of accessories. Please refer to the separate data sheets for information and ordering details for transmitters and displays. The parts can be assembled by the user or delivered assembled and calibrated, if relevant. Provided an 80 mm dia. housing is used, options are also a 4...20 mA configurable display or, for stand alone indicating purposes, a battery powered display. www.baumer.com Design and specifications subject to change without notice Data Sheet 2000-1 Page Technical Data Environmental conditions Sensor tube and connection Media temperature, std. -50...400°C Material Acid-proof, stainless steel Surface sensor -40...150°C (AISI 316L/W.1.4404) Ambient temperature -40...160°C Media pressure Max. 16 bar (or max. temperature range for display/transmitter) Time constant t0.5 See table below Humidity Mechanical tolerances ISO 2768-m < 100% RH, condensing (or max. humidity for display/transmitter) Sensor element Protection class DIN housing IP 65 ø80 mm housing IP 65 + IP 66 Vibrations Sensor type Pt100, Class A or B Pt1000, Class B GL, test 2 Accuracy DIN/EN/IEC 60751 (sensor tubes < 200 mm only) 1/1 DIN B 1/3 DIN B 1/6 DIN B 1/1 DIN A ±(0.3 + 0.005 x t) °C +1/3 x (0.3 + 0.005 x t) °C +1/6 x (0.3 + 0.005 x t) °C +(0.15 + 0.002 x t) °C Disposal of product and packing According to national laws or by returning to Baumer Time Constant τ0.5 Sensor type Liquids Dimension Response Insert ø6 mm tube fast ø8 mm tube fast ø10 mm tube fast ø12 mm tube fast ø6 mm tube normal ø8 mm tube normal ø10 mm tube normal ø12 mm tube normal ø8 mm tube normal 5.6 mm ø10 mm tube normal 5.6 mm ø12 mm tube normal 5.6 mm Surface sensor, flush mounted 0.4 m/sec. < 1.5 sec. < 1.5 sec. < 1.5 sec. < 1.5 sec. < 6.1 sec. < 7.6 sec. < 11.1 sec. < 16.2 sec. < 13.6 sec. < 28.1 sec. < 31.3 sec. < 1.0 sec. Air 3 m/sec. < 21.4 sec. < 33.6 sec. < 46.8 sec. < 59.9 sec. < 27.2 sec. < 47.7 sec. < 57.8 sec. < 70.8 sec. < 51.1 sec. < 67.0 sec. < 82.3 sec. 0 m/sec. < 135.6 sec. < 181.0 sec. < 238.9 sec. < 311.4 sec. < 137.8 sec. < 200.9 sec. < 270.6 sec. < 319.8 sec. < 253.1 sec. < 271.1 sec. < 289.3 sec. Dimensional Drawings - Mounting Details [mm] 76 55 85 58 71 G1/4A 7.5 12.5 Clamp ISO 2852, DN38 mounted on a Stainless steel housing, ø55 mm www.baumer.com Design and specifications subject to change without notice Male Nipple G1/2A Male Nipple G1/2A mounted on DIN B housing 11 Male Nipple G1/2A mounted on ø80 mm housing Data Sheet 2000-1 Page Examples of Application [mm] R 74 - 03 8141 4211 0500 110 xxxx 8141 H241 07F0 110 xxxx 8142 D232 0500 110 xxxx 8142 C252 0000 000 xxxx +CombiConnect connection R 74 - 03 R 74 - 03 8140 0007 03A2 010 0000 Cable sensor 8155-3xx-xxxx BattTemp 86 30-511 8142 D231 02A2 213 xxxx Display 81 46-525 Transmitter 22xx-000x 8142 3212 02A1 110 xxxx 8141 3211 0272 010 xxxx BattTemp 86 30-511 R PTFE Thermal isolation 74 - 03 8140 E010 02A2 213 0000 Display 81 46-525 Transmitter 22xx-000x 8142 D231 07F0 210 xxxx Transmitter 22xx-000x 8141 3212 12A2 121 xxxx Sensor Tube and -Element Selection Table Sensor tube [mm] Embedded sensor, max. [mm] 6 6000 8 6000 10 12 Cable sensor, max. [mm] Single, 2-wire Duplex, 2-wire Single, 4-wire x x x 1000 x x x 6000 6000 x x x 6000 6000 x x x www.baumer.com Design and specifications subject to change without notice Duplex, 4 wire x Data Sheet 2000-1 Page Ordering Details - CombiTemp Series Sensor tip Not specified Normal response sensor tip Fast response sensor tip, Note {1}, {6} Connection Not specified Sensor tube without thread or connection R1/2 Male nipple, ISO 7/1 G1/2A Male nipple, ISO 228/1 G1/2 Rotating female nut, ISO 228/1 G1/2A Rotating male nipple, ISO 228/1 G3/4 Rotating female nut, ISO 228/1 G3/4A Rotating male nipple, ISO 228/1 G1 Rotating female nut, ISO 228/1 G1A Rotating male nipple, ISO 228/1 1/2“ - 14 NPT Male nipple, ANSI/ASME B1.20.1 G1/2A Male nipple for CombiConnect, ISO 228/1 3A/DN38 Hygienic, sensor tube, 3-A conform, Note {8} 3A/DN38 Hygienic, flush mounted surface sensor, 3-A conform, Note {8} GEA Tuchenhagen Varivent flange, DN40/DN50 Clamp DN25/38, ISO 2852, 3-A conform, Note {8} Clamp DN51, ISO 2852, 3-A conform, Note {8} 1/2" - 3/4" Tri-clamp® M20 x 1.5 Male nipple, DS/ISO 261 SMS 1145 Rotating female nut, DN38 SMS 1145 Rotating female nut, DN51 As customer specification 4´ digit 5´ digit 0 1 2 3 4 5 6 7 8 9 A C D E G H I K M P Q S Sensor tube dimension 6´ digit Not specified ø6 mm x 1 mm, AISI 316L, see table page 3 ø8 mm x 1 mm, AISI 316L, see table page 3 ø10 mm x 1 mm, AISI 316L, see table page 3 ø12 mm x 1 mm, AISI 316L, see table page 3 As customer specification Sensor element 7´ digit Not specified or empty sensor tube Pt100, 1/1 DIN B, single, specified accuracy -50...400°C Pt100, 1/1 DIN B, duplex, specified accuracy -50...400°C Pt100, 1/3 DIN B, single, specified accuracy 0...150°C Pt100, 1/3 DIN B, duplex, specified accuracy 0...150°C Pt100, 1/6 DIN B, single, specified accuracy 0...100°C Pt100, 1/6 DIN B, duplex, specified accuracy 0...100°C Pt100, 1/1 DIN A, single, specified accuracy -50...400°C Pt100, 1/1 DIN A, duplex, specified accuracy -50...400°C Pt100, 1/1 DIN B, single, specified accuracy -50...600°C, Note {7} Pt1000, 1/3 DIN B, single, specified accuracy -50...400°C Pt1000, 1/1 DIN B, single, specified accuracy -50...400°C As customer specification Sensor insert type Not specified Sensor tube with embedded sensor element, 2-wire Sensor tube with embedded sensor element, 4-wire ø5.6 x 0.5 mm insert AISI 316, 2-wire, max. length 600 mm, Note {3}, {7} ø5.6 x 0.5 mm insert AISI 316, 4-wire, max. length 600 mm, Note {3}, {7} ø5.6 x 0.5 mm insert spring-loaded AISI 316, 2-wire, max. length 600 mm, Note {3}, {7} ø5.6 x 0.5 mm insert spring-loaded AISI 316, 4-wire, max. length 600 mm, Note {3}, {7} Cable sensor, 4-wire, Note {4} www.baumer.com Design and specifications subject to change without notice 814x xxxx - - - - - - - - - - - - - 0 1 2 0 1 2 3 4 S 0 1 2 3 4 5 6 7 8 9 A B S 8´ digit 0 1 2 3 4 5 6 7 Data Sheet 2000-1 Page Ordering Details - CombiTemp Series (continued) - - - - - - xxxx xxx Cooling neck Not specified 1 off cooling neck (71 mm) 2 off cooling neck (142 mm) 3 off cooling neck (213 mm) As customer specification 0 1 2 3 S Housing Not specified ø80 mm stainless steel housing, Note {5} ø80 mm stainless steel housing with ø110 mm wall bracket, Note {5} DIN B head with cover and M20 gland DIN B head with cover and M20 gland, shield connection terminal TE1 Field housing (no display) As customer specification 10´ digit Electrical connection Not specified or std. DIN B head selected in the previous choice ø80 mm housing: 1 off M20 x 1.5 adaptor and 1 off blind plug (no gland incl.) ø80 mm housing: 2 off M20 x 1.5 adaptor (no gland incl.) ø80 mm housing: 2 off blind plugs ø80 mm housing: 1 off M16 gland and 1 off blind plug ø80 mm housing: 2 off M16 gland ø80 mm housing: 1 off M16 with shield connection terminal and 1 off blind plug DIN B head: 1 off M20 gland for marine applications TE1 housing: M12 plug, 4 pole TE1 housing: M16, plastic TE1 housing: M16 gland, nickel plated brass TE1 housing: M16 gland, nickel plated brass, with earth connection terminal ø80 mm housing: M12 plug, 4 pole As customer specification 11´ digit Cover or display Not specified Cover for ø80 mm housing Display, Note {4} Terminal block or transmitter Not specified Ceramic terminal block Transmitter, Note {4} 12´ digit Assembling Not specified Assembled, process connection at the base Assembled, process connection at the rear (ø80 mm housing only) Welded, process connection at the base (ø80 mm housing only) Welded, process connection at the rear (ø80 mm housing only) 14´ digit Approvals Standard version Ex ia (zone 0) II 1 G EEx ia IIC Ex n (zone 2) II 3 G EEx nA II 15´ digit Sensor tube length (L) Length in mm. Please observe max. lengths xxxx 9´ digit 0 2 3 5 6 7 S 0 5 6 7 A B C D E F G H I S 0 1 2 13´ digit 0 1 2 0 1 2 3 4 0 4 5 16...19´ digit xxxx Calibration certificate, -30...150°C, 4 points, order type number 5509-142 Material certificate, 3.1 (EN10 204), order type number 5509-227 Cable type no.: 132548 4 pol M12 plug with 5m cable 127804 4 pol M12 angle plug with 5m cable www.baumer.com Design and specifications subject to change without notice Data Sheet 2000-1 Page Notes: {1} Single sensor element only. Max. sensor length 300 mm. {3} ø80 mm housing: Insert only if sensor tube is mounted at the rear. Observe length, refer to „Sensor Insert Type“. {4} Refer to data sheet. Specify separate type number and configuration. {5} Assembling is mandatory. Valid for 3A applications. {6} Embedded sensors only. {7} Not valid for a sensor with fast response tip. Dimensional Drawings [mm] 12.5 12.5 AF22 27.5 G1/2A G3/4A G1A L G1/2A G3/4A G1A 27.5 32 35 L ø6...12 ø6...12 ø4...12 ø4...12 AF27 AF32 AF36 Male nipple G1/2A, R1/2 and M20 x 1.5 Rotating male nipple G1/2A, G3/4A and G1A R 57 74 - 03 DN25/38 DN51 L ø6...12 ø4...12 Clamp DN25/38/51 EPDM gasket included, Note {8} www.baumer.com Design and specifications subject to change without notice G1/2 G3/4 G1 51 ø50.5 ø64 L AF27 AF32 AF41 ø6...12 ø4...12 Rotating female nut G1/2, G3/4 and G1 Data Sheet 2000-1 Page Dimensional Drawings R R 36 74 - 03 36 AF22 74 - 03 52 31.5 31.5 ø6...12 L ø6...12 L ø4...12 ø4...12 Male nipple G1/2A for CombiConnect 3A/DN38 hygienic sensor tube EPDM O-ring included, Note {8} 3A/DN38 hygienic flush mounted surface sensor EPDM O-ring included, Note {8} [mm] 12.5 12.5 AF22 6 51.5 34.4 ø6...12 L ø6...12 L ø4...12 ø6...12 L ø4...12 ø4...12 DN38 DN51 Male nipple 1/2“ - 14 NPT Sensor tube without connection ø25 30 ø55 ø65 SMS 1145 rotating female nut 25 19 L ø6...12 ø4...12 L ø6...12 ø4...12 Tri-Clamp® 1/2 - 3/4 www.baumer.com Design and specifications subject to change without notice GEA Tuchenhagen Varivent DN40/DN50 Data Sheet 2000-1 Page Sensor inserts Calculation of insert length: When ordering an insert the length must be calculated from the formula: Housing shaft {8} Total body length Insert length = Sensor length + total body length + housing shaft (Total body length can be calculated from the dimensional drawings on pages 6 and 7) Sensor length (L) Example. Insert for a G1/2A male nipple sensor in a DIN housing, 100 mm sensor tube, normal response sensor tip: Housing shaft = 11.5 mm Total body length = 27.5 + 12.5 = 40 mm (see page 6) Sensor length = 100 mm DIN housing with G1/2A male nipple connection and sensor insert Note {8} Housing shaft DIN housing: 11.5 mm ø80 housing: 6.5 mm This insert must be ordered with a 151.5 mm sensor tube. Notes Single sensor element only. Max. sensor length 300 mm. ø80 mm housing: Insert only if sensor tube is mounted at the rear. Observe length, refer to „Sensor Insert Type“. Refer to data sheet. Specify separate type number and configuration. Assembling is mandatory. Valid for 3-A applications. Embedded sensors only. Not valid for a sensor with fast response tip. {8} The 3-A mark is valid only when the product is mounted in a 3-A marked counter part and installed according to the installation manual. Use also a 3-A marked O-ring or gasket if relevant. The 3-A marked products conforms to the 3-A Sanitary Standard criteria. Materials and surfaces fulfill the FDA demands and follow the EHEDG guidelines regarding design, materials and finishing. EPDM O-rings supplied with 3-A marked products are conform to Sanitary Standard Class II (8% milk fat max.) EPDM gaskets supplied with 3-A marked products are conform to Sanitary Standard Class I (8% milk fat max.) 4-wire Sensors White White Duplex Elements Red Red White White Red Red Warning: One of the wires may not be connected in case of a 3-wire connection to the temperature transmitter Application Photos ø80 mm housing with FlexView Gland (blind plug at the rear) Clamp connection Fast response sensor Cut through DIN - B housing FlexTop 2201 temperature transmitter G1/2A male nipple connection Normal response sensor www.baumer.com Design and specifications subject to change without notice UK/2010-02-02 This data sheet may only be reproduced in full. {1} {3} {4} {5} {6} {7} ø80 mm housing with 2 glands Cover not mounted 3A/DN38 connection at the rear Fast response sensor Data Sheet 2000-1 Page