M-Series M-Series CIRCUIT BREAKER The M-Series is a low cost, miniature, hydraulic-magnetic circuit breaker which features a compact, space saving design, front panel snap-in mounting and a vertically mounted parallel pole configuration. It features various styling options to maximize your design flexibility. Choices include rocker, illuminated rocker, paddle and baton style handle actuators, push-to-reset and push-pull pushbutton actuators, as well as Visi-Rocker two color actuators. Our exclusive Rockerguard bezel helps prevent inadvertent actuation and a wiping contact mechanism assures long-term reliability. The M-Series circuit breakers are available with 1, 2 or parallel poles, 0.02 to 50 amp ratings, and 125 and 250VAC or 80VDC versions. With over 16 different time delays, 5 terminal styles, a variety of panel hardware, various colors, and legend imprinting, it assures suitability for most any application design. Resources: Download 3D CAD Files IGS Product Highlights: Parallel pole configuration fits in one rack unit MIL-PRF-55629 MIL STD 202 compliant MIL-PRF-39019F ingress protection Sealed toggle actuator Compact design STP Typical Applications: Telecom/Datacom Transportation Marine Generators Power Supplies Medical Equipment Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | M-Series Circuit Breaker - General Specifications Electrical Maximum Voltage 125/250 VAC 50/60 Hz, 80 VDC (See Rating Tables.) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00 thru 15.0 in 1 amp increments, 18.0, 20.0, 25.0, 30.0. Other ratings available - see Ordering Scheme. Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res) 28VDC, 4A (Ind.) 28VDC, 0.25A 80VDC (Res) (silver contacts), 0.1A 125VAC (gold contacts). Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA 1500V, 50/60 Hz for one minute between all electrically isolated terminals. M-Series Circuit Breakers comply with the 8mm spacing and 3750 V 50/60Hz dielectric requirements from hazardous voltage to operator accessible surfaces, per Publications IEC 380, 435, 950, EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) CURRENT TOLERANCE (AMPS) (%) 0.10 - 20.0 20.1 - 50.0 ± 25 ± 35 Pulse Tolerance Curves Mechanical Endurance 10,000 ON-OFF operations @ 6 per minute with rated Current and Voltage. Trip Free All M-Series Circuit Breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. Physical Number of Poles Internal Circuit Configs. Weight Standard Colors 1 or 2 Series with or without Auxiliary Switch. Switch Only with or without Auxiliary Switch. Approximately 30 grams/pole (Approximately 1.07 ounces/pole) See Ordering Scheme.a Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Cond. I. Instantaneous curves tested at 80% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous curves tested at 80% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80 98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C Chemical Resistance Only the outside surfaces of the case and the handles may be cleaned with detergents or alcohol. Organic (hydrocarbon based) solvents are not recommended because they attack plastics. Caution should be taken when solvents are used to clean and remove flux from terminals. Lubricants should not be introduced into the handle/ bushing openings *Manufacturer reserves the right to change product specification without prior notice. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized and CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. M-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS Voltage Circuit Configuration Max Rating 32 50 2 65 65 1,2 65 Series 80 1 125 250 2 250 250 Current Rating Short Circuit Capacity (Amps) Poles UL / CSA Load General Breaking With Backup Without Backup Frequency Phase Full Amps Purpose Amps Fuse Fuse 0.02 - 15 --1 --1000 DC ----15.1 - 25 1 --1000 DC --0.02 - 7.5 --1 --1000 0.02 - 15 --2 --1000 DC ----15.1 - 25 2 --1000 0.02 - 15 --1 --1000 DC ----15.1 - 30 1 --1000 0.02 - 15 --2 5000 3 --DC ----15.1 - 25 2 5000 3 --0.02 - 15 --1 --600 DC ----15.1 - 30 1 --600 0.02 - 15 --1 --1000 50 / 60 1 --15.1 - 30 1 --1000 1 - 30 --1 --360 50 / 60 1 0.02 - 12 --1 --1000 50 / 60 1 --12.1 - 18 1 1000 4 --0.02 - 15 --2 --1000 50 / 60 1 --15.1 - 30 2 --1000 1 - 30 --2 --360 Application Codes UL CSA TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, C1 TC1, 2, OL0, C1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL0, C1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, C1 TC1, 2, OL0, C1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC3, OL1, U3 TC1, 2, OL1, U1 TC1, 2, OL0, C1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC3, OL1, U3 Notes: 1 Polarity Sensitive 2 Available only with Special Catalog Number. Consult Factory. 3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum 4 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certified configurations and performance capabilities as a Component Supplementary Protector. M-SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS Voltage Circuit Configuration Series Max Rating Current Rating Load Frequency Phase Full Amps 32 DC --- 50 2 DC --- 65 DC --- 65 3 DC --- 80 1 DC --- 125 50 / 60 1 250 50 / 60 1 0.02 - 15 --0.02 - 7.5 0.02 - 15 --0.02 - 15 --0.02 - 15 --0.02 - 15 1 - 15 0.02 - 12 0.02 - 20 1 - 12 Short Circuit Capacity (Amps) UL / CSA VDE / TUV Poles General Without With Without Purpose Breaking With Backup Backup Backup Backup Amps Fuse Fuse Fuse Fuse --1 --1000 3000 500 15.1 - 25 1 --1000 3000 500 --1 --1000 3000 500 --2 --1000 3000 500 15.1 - 25 2 --1000 3000 500 --2 5000 --3000 500 15.1 - 30 2 5000 --3000 500 --1 --600 4 --500 15.1 - 30 1 --600 4 --500 --1 --1000 3000 500 --1 --360 3000 500 --1 --1000 3000 500 --2 --1000 3000 500 --1 --360 3000 500 Application Codes UL CSA TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, C1 TC1, 2, OL0, C1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, C1 TC1, 2, OL0, C1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, 2, OL1, U1 TC3, OL1, U3 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC3, OL1, U3 Notes: 1 Polarity Sensitive 2 Available only with Special Catalog Number. Consult Factory. 3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum 4 TUV only, not VDE 5 Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15amps, and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 4 | M-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL489A Listed and TUV Certified configurations and performance capabilities for use in Communications Equipment. M-SERIES TABLE C: UL489A Listed Circuit Configuration Series (Communications Equipment - Polarity Sensitive) Voltage Interrupting Capacity (Amps) Current Rating Poles Without Backup Fuse General Purpose Breaking Max Amps Rating Frequency UL489A TUV 80 65 1 80 DC DC DC 0.02 - 30 0.02 - 30 0.10 - 25 1 1 1 600 1000 600 ----600 Notes: 1. Available only with Special Catalog Number Table D: Lists UL489A Listed configurations and performance capabilities for use in Communications Equipment. M-SERIES TABLE D: Parallel Pole Construction UL489A Listed (Communications Equipment - Polarity Sensitive) Circuit Configuration Series Voltage Max Rating 80 65 1 Current Rating Poles General Purpose Breaking Frequency Amps DC DC 31 - 50 31 - 50 Interrupting Capacity (Amps) Without Backup Fuse UL489A 2 2 600 1000 Notes: 1. Available only with Special Catalog Number Agency Certifications UL Recognized UL Standard 1077 UL Listed UL Standard 489A Component Recognition Program as Protectors, Supplementary (Guide CCN/QVNU2, File E75596) Communications Equipment (Guide CCN/DITT, File E189195) CSA Accepted Component Supplementary Protector (Class 3215 30, File 047848 0 000) CSA Standard C22.2 No. 235 VDE Certified EN60934, VDE 0642 under File 10537 TUV Certified EN60934, under License No. R9671109 Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Parallel Pole Rocker - Ordering Scheme | 5 M E 2 1 Series 2 Actuator 3 Poles P 4 Circuit D2 650 5 Frequency & Delay 6 Current Rating A 1 2 9 8 Illumination Actuator Color & Legend 10 Legend 7 TERMINAL A Push in Stud 5 10-32 Screw (Bus Type) 1 SERIES M 2 ACTUATOR Single Color A Angled BFlat 5 7 Terminal Two Color Visi D Indicate ON E Indicate OFF Single Color Translucent F Angled G Flat 8 ILLUMINATION Non-Illuminated A Non-Illuminated 9 ACTUATOR COLOR & LEGEND Actuator Visi 1 1 White 2Black 3Red 4Green 5Blue 6 Yellow 7 Gray 8 Orange 10 LEGEND 2 ON - OFF Vertical 3 ON - OFF Horizontal 6 Dual Vertical 7 Dual Horizontal 3 POLES 2Two 4 CIRCUIT/AUXILIARY SWITCH 2 P Series Trip Current (Parallel Pole) with Auxiliary Switch, Silver Contacts Q Series Trip Current (Parallel Pole) with Auxiliary Switch, Gold Contacts R Series Trip Current (Parallel Pole) 5 FREQUENCY & TIME DELAY D2 DC Short D4 DC Medium Legend Black White White White White Black Black Black .110 x 0.20 Q.C .110 x 0.20 Q.C 11 BEZEL COLOR A White without Rockerguard B Black without Rockerguard G Gray without Rockerguard 1 White with Rockerguard 2 Black with Rockerguard 7 Gray with Rockerguard 12 AGENCY APPROVAL T UL 489A Listed 6 CURRENT RATING (AMPERES) CODEAMPERES 631 635 640 645 650 31.000 35.000 40.000 45.000 50.000 Notes: 1 Reminder of Rocker same color as Visi 2 Aux Switch only available with screw terminals Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B 11 Bezel Color T 12 Agency Approval 6 | M-Series Circuit Breaker - Parallel Pole - Handle / Push Button - Ordering Scheme M M 2 1 Series 2 Actuator 3 Poles P 4 Circuit D2 650 5 Frequency & Delay 6 Current Rating 2 ACTUATOR M Paddle TPush-Pull 3 POLES 2Two .110 x 0.20 Q.C .110 x 0.20 Q.C 5 FREQUENCY & TIME DELAY D2 DC Short D4 DC Medium 6 CURRENT RATING (AMPERES) B T 9 Front Panel Hardware 11 Brushing Color 12 Agency Approval 10 Legend Plate/ Marking 10 LEGEND PLATE / BUTTON MARKING Handle Actuator Legend Plate B ON - OFF Vertical C ON - OFF Horizontal Push-Pull Actuator Legend Plate 2 Rated Amps Horizontal 3 Rated Amps Line Side Down 4 Rated Amps Line Side Up 11 BUSHING COLOR B Black CODEAMPERES 631 635 640 645 650 1 B B 8 Actuator Color 9 FRONT PANEL HARDWARE Handle A No outer Panel Hardware B Knurled Nut, Bright Nickel C Knurled Nut, Bright Nickel with Locking Ring D Knurled Nut, Black E Knurled Nut, Black with Locking Ring F Panel Dress, Bright Nickel G Panel Dress, Bright Nickel with Locking Ring H Panel Dress, Black J Panel Dress, Black with Locking Ring Push Button 1 No outer Panel Hardware 2 Knurled Nut, Bright Nickel 1 SERIES M 4 CIRCUIT/AUXILIARY SWITCH 1 P Series Trip Current (Parallel Pole) with Auxiliary Switch, Silver Contacts Q Series Trip Current (Parallel Pole) with Auxiliary Switch, Gold Contacts R Series Trip Current (Parallel Pole) 5 7 Terminal 31.000 35.000 40.000 45.000 50.000 12 AGENCY APPROVAL T UL 489A Listed Notes: 1 Aux Switch only available with screw terminals 7 TERMINAL A Push in Stud 5 10-32 Screw (Bus Type) 8 ACTUATOR COLOR & LEGEND Handle 1 White 2 Black 3 Red 4 Green 5 Blue 6 Yellow 7 Gray 8 Orange Push Button A White BBlack CRed DGreen EBlue FYellow GGray HOrange Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Parallel Pole - Dimensional Specifications | 7 Dimensional Specifications: in. [mm] PARALLEL POLE TERMINAL OPTIONS PUSH-IN STUD 10-32 SCREW W/ BUS BAR .652 [16.56] .912 [23.16] 1.125 [28.58] 1.000 [25.4] .838 [21.29] .154 [3.91] .393 [9.97] 1.000 [25.4] .100 [2.54] .750 [19.05] ROCKER ACTUATOR DETAIL INDICATE "ON" (VISI-ON) .370 [9.40] MAX. ±.020 1.394 [35.41] [±.508] ±.020 1.530 [38.86] [±.508] 1.304 [33.12] LINE 1.375 [34.93] OFF 1.560 [39.62] .970 [24.64] 1.125 [28.58] ON LOAD .400 [10.16] .625 [15.88] .100 [2.54] ROCKERGUARD CONFIGURATION INDICATE "OFF" (VISI-OFF) & SINGLE COLOR ±.020 ±.020 ±.508 ±.508 .305 [7.75] .675 [17.14] LOAD ON LOAD ON ±.020 ±.508 1.050 [26.67] OFF LINE OFF LINE 5 PANEL CUT - OUT DETAIL (ROCKER) DOUBLE POLE PANEL THICKNESS DIM. A ±.005 ±.13 NO 1 2 3 4 DIM. A +.005 +.13 -.000 -.00 .062 [1.57] 1.385 [35.18] .093 [2.36] 1.420 [36.07] .125 [3.18] 1.460 [37.08] 1.139 [33.76] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.010 [.25] unless otherwise specified. 3 Dimensions apply to both rocker styles. 4 I-o, on-off or dual legends available for vertical or horizontal mounting. 5 Notice that circuit breaker line and load terminal orientation on indicate “off” is opposite that of indicate “on”. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 8 | M-Series Circuit Breaker - Parallel Pole - Dimensional Specifications Dimensional Specifications: in. [mm] PADDLE ACTUATOR STYLE PUSH-PULL ACTUATOR STYLE 1.484 1.395 1/2-32 THD. 3/8" 8-32 THD. 12° ON OFF ACTUATOR COLOR VISIBLE IN OFF POSITION ONLY FLAT 12° ±.030 ±.030 ±.76 .500 [12.70] OFF (SHOWN) FLAT ±.030 .470 [11.94] .400 [10.16] ±.76 ±.030 .280 [7.11] ON ±.76 ±.76 .500 [12.70] MOUNTING DETAILS PANEL HARDWARE MOUNTING DETAILS +.010 -.000 +.010 -.000 +.25 -.000 +.010 -.000 ±.002 ±.05 PUSH-PULL, PUSH TO RESET +.25 -.000 +.010 -.000 ±.005 [±.13] .125 DIA [Ø3.18] +.25 -.00 ±.002 [±.050] .098 [2.49] .375 [9.53] DIA .162 [4.11] .355 [9.02] .494 [12.55] +.25 -.000 .500 DIA [Ø12.70] .500 DIA [Ø12.70] HEX NUT .222 [5.64] WITH LOCKING RING .544[13.82] WITHOUT LOCKING RING .156 [3.56] .625 [15.87] DIA .534 [13.56] .078 [1.98] LEGEND PLATES SNAP-IN BUSHING .025 [.64] .435 [11.05] DIA .632 DIA [Ø16.05] .340 [8.64] PANEL DRESS NUT 0N 1.025 [26.04] O F F O N BUTTON MARKING ORIENTATION 0FF LEGEND CODE: B LINE C 20 LINE 20 20 3 4 PANEL HARDWARE LINE .625 [15.88] .680 DIA [Ø17.27] .125 [3.18] .180 [4.57] MARKING CODE: 2 NOTES: .110QC AUXILIARY SWITCH1. TERMINALS ALL DIMENSIONS PANEL DRESS NUT HEX NUT .680 DIA [Ø17.27] .105 [2.67] .125 [3.18] .031 [.79] .683 DIA [Ø17.27] KNURLED NUT .342 [8.69] ARE I 2. TOLERANCE ±.010 [.25] 3. DIMENSIONS APPLY TO 4. I-O, ON-OFF OR DUAL L VERTICAL OR HORIZON 5. NOTICE THAT CIRCUIT ORIENTATION ON INDIC INDICATE "ON". TITLE LOCKING RING Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.010 [.25] unless otherwise specified. 3 Dimensions apply to both rocker styles. 4 I-o, on-off or dual legends available for vertical or horizontal mounting. 5 Notice that circuit breaker line and load terminal orientation on indicate “off” is opposite that of indicate “on”. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com DR BY ME 5/10/12 M-Series Circuit Breaker - Handle/Pushbutton UL Recognized - Ordering Scheme | 9 M M 1 1 Series 2 Actuator B 34 4 Circuit 3 Poles 260 5 Frequency & Delay 6 Current Rating 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 Handle M Paddle NBaton Push Button TPush-Pull Push Button with Snap-In Mounting VPush-Pull U Push To Reset W Push To Reset 3 POLES One 2Two 4 CIRCUIT 2 without Auxiliary Switch A Switch Only (no coil), Maintained Contacts B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: M Series Trip (Current) Aux Switch .110 QC x .020 QC P 3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret Q 3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C. R 3,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. S3 Series Trip (Current) .060 Dia, Round Solder Turret T 3,4 Series Trip (Current) .058 Dia, Round Q.C. 3,13 U Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 3,4 2 Switch Only, Maintained Contacts .058 Dia, Round Q.C. 3 3,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. 4 3,4 Series Trip (Current) .058 Dia, Round Q.C. 5 3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 9 Series Trip (Current) Aux Switch .110 QC x .020 QC 5 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 12 DC Short 14 DC Medium 20 50/60Hz Instantaneous 22 50/60Hz Short 24 50/60Hz Medium 30 DC, 50/60Hz Instantaneous 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 62 50/60Hz Short, Hi-Inrush 64 50/60Hz Medium, Hi-Inrush 72 DC, Short,Hi-Inrush 74 DC,Medium, Hi-Inrush 92 DC, 50/60Hz Short, Hi-Inrush 94 DC, 50/60Hz Medium, Hi-Inrush Full Load Amp Tungsten Lamp General Purpose Amps Rating Rating Poles Choose Choose Breaking Max Frequency Phase Max Current Max Choose Current Max Current Coil Coil Rating Amps Rating Code Amps Coil Rating Code Amps Rating Code Voltage DC DC DC 50/60Hz 50/60Hz 50/60Hz C B 9 10 Front Panel Legend Hardware Plate 11 Bushing Color 12 Agency Approval CODEAMPERES 2 ACTUATOR 1 32 50 65 125 250 250 1 B B 8 Actuator Color 6 CURRENT RATING (AMPERES) 8 1 SERIES M 1 1 7 Terminal 1 1 1 1 15 15 15 12 15 615 615 615 612 615 25 7.5 25 25 25 625 Consult Factory 625 625 625 15 - 615 - 1 1 2 1 1 2 Notes: 1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited to single pole breakers only. 2 Switch Only circuits are not available with Push-To-Reset actuators. For Switch Only circuits, select Current Coil Rating from the above chart: 3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with back connect screw or push-in stud terminals. 4 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and 60983-2 (tin plated). 5 Actuator color is only visible in the OFF position on Push-Pull actuators. 6 All units except snap-in mounting have one hex nut installed on bushing for use behind the panel. 7 Other colors available. Consult factory. 8 TUV and VDE Certification above 15 amps is for 2-pole only and is limited to a max. of 20 amps. Screw Terminal or Push-In Stud recommended above 20 amps. 9 30 amp rating not available with delay’s 30, 32, 34, 92 or 94. 10 Screw Terminals are VDE certified only with use of ring terminal attached to wire. 11 Terminal code A available with circuit codes A & B only. 12 Printed circuit board available with UL recognized approval only. 13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only. 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 5171.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 61010.000 7 TERMINAL 8 1 Push-On 0.250 Tab (Q.C.) 2 10 Screw 8-32 with Upturned Lugs 3 10 Screw 8-32 (Bus Type) 8 ACTUATOR COLOR & LEGEND 5 Gloss Handle Push-Button 1A 2B 3C 4D 5E 6F 8H 9 FRONT PANEL HARDWARE 6 Handle No outer Panel Hardware A Knurled Nut Bright nickel B Bright nickel with locking ring C Black D Black with locking ring E Panel Dress Nut Bright nickel F Bright nickel with locking ring G Black H Black with locking ring J A 11 P 12 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 Push-In Stud Printed Circuit Board Actuator Color White Black Red Green Blue Yellow Orange Push-Button 1 2 10 LEGEND PLATE / BUTTON MARKING Handle Actuator Legend Plate (Actuator Styles M & N) A No Legend Plate B ON - OFF Vertical C ON - OFF Horizontal D I - O Vertical E I - O Horizontal Push-Pull Actuator Button Cap (Actuator Styles T & V) 1 No Marking 2 Rated Amps Horizontal 3 Rated Amps Line Side Down 4 Rated Amps Line Side Up Push-to-Reset Actuator Button (Actuator Styles U & W) 1 No Marking 11 BUSHING COLOR 7 B Black 12 AGENCY APPROVAL 9 C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 10 | M-Series Circuit Breaker - Handle/Pushbutton UL489A/UL Recognized – Ordering Scheme M M 1 1 Series 2 Actuator B 14 4 Circuit 3 Poles 5 Frequency & Delay 620 6 Current Rating 2 ACTUATOR 1 Handle M Paddle NBaton Push Button TPush-Pull Push Button with Snap-In Mounting VPush-Pull U 8 Push To Reset W 8 Push To Reset 3 POLES One 4 CIRCUIT without Auxiliary Switch B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: M Series Trip (Current) Aux Switch .110 QC x .020 QC S3 Series Trip (Current) .060 Dia, Round Solder Turret T 3,4 Series Trip (Current) .058 Dia, Round Q.C. U 3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 4 2,3 Series Trip (Current) .058 Dia, Round Q.C. 5 3,12 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 9 Series Trip (Current) Aux Switch .110 QC x .020 QC 5 FREQUENCY & DELAY 10 DC Instantaneous 12 DC Short 14 DC Medium 72 DC, Short,Hi-Inrush 74 DC,Medium, Hi-Inrush 6 CURRENT RATING (AMPERES) CODEAMPERES 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 1 2 3 4 5 6 7 8 9 10 11 12 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 1 B B B J 9 10 Front Panel Legend Hardware Plate 11 Bushing Color 12 Agency Approval 8 Actuator Color 7 TERMINAL 4 1 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 with Upturned Lugs 3 Screw 8-32 (Bus Type) 1 SERIES M 1 1 7 Terminal 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 5171.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 61010.000 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 8 ACTUATOR COLOR & LEGEND 5 Gloss Handle Push-Button 1A 2B 3C 4D 5E 6F 8H 9 FRONT PANEL HARDWARE 6 Handle No outer Panel Hardware A Knurled Nut Bright nickel B Bright nickel with locking ring C Black D Black with locking ring E Panel Dress Nut Bright nickel F Bright nickel with locking ring G Black H Black with locking ring J A 10 P 11 Push-In Stud Printed Circuit Board Actuator Color White Black Red Green Blue Yellow Orange Push-Button 1 2 10 LEGEND PLATE / BUTTON MARKING Handle Actuator Legend Plate (Actuator Styles M & N) A No Legend Plate B ON - OFF Vertical C ON - OFF Horizontal D I - O Vertical E I - O Horizontal Push-Pull Actuator Button Cap (Actuator Styles T & V) 8 1 No Marking 2 Rated Amps Horizontal 3 Rated Amps Line Side Down 4 Rated Amps Line Side Up Push-to-Reset Actuator Button (Actuator Styles U & W) 8 1 No Marking 11 BUSHING COLOR 7 B Black 12 AGENCY APPROVAL 9 J UL489A Listed, TUV Certified M UL Recognized, CSA Accepted N UL Recognized, TUV Certified T UL489A Listed One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited to single pole breakers only. One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with Back Connected Screw or Push-in Stud terminals. Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and 60983-3 (tin plated). Screw terminals or Push-in Stud recommended above 20 amps. Actuator color is only visible in the OFF position on Push-Pull actuators. All units have one hex nut installed on bushing for use behind the panel. Other colors available. Consult factory. Not available with UL489A Listed breakers. TUV certified to 25 amps. UL Recognized, CSA Accepted and UL Listed to 30 amps. Terminal code A available with circuit codes A & B only. Printed circuit board available with UL recognized approval only. Auxiliary switch (flat Q.C.) available with UL recognized approvals only. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams | 11 Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 12 | M-Series Circuit Breaker - Handle – PC Terminal Diagrams PC Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Handle - Dimensional Specifications | 13 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 14 | M-Series Circuit Breaker - Pushbutton – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Pushbutton – Dimensional Specifications | 15 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. 3 Available with Push-Pull or Push-to-Reset Actuators Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 16 | M-Series Circuit Breaker - Push-Pull – PC Terminal Diagrams PC Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme | 17 M G 2 1 Series 2 Actuator 3 Poles B 34 4 Circuit 5 Frequency & Delay 620 6 Current Rating 1 SERIES M 9 8 Illumination Actuator Color 7 Terminal 7 10 Legend C 11 Bezel Color 12 Agency Approval CODEAMPERES Non-Illuminated Two Color single color Visi-Rocker A AngledD Indicate ON B Flat E Indicate OFF illuminated single color F Angled G Flat 3 POLES One H C 6 6 CURRENT RATING (AMPERES) 2 ACTUATOR 1 1 1 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 5171.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 61010.000 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 6301230.000 2Two 4 CIRCUIT 2 without Auxiliary Switch A Switch Only (no coil), Maintained Contacts B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: M Series Trip (Current) Aux Switch .110 QC x .020 QC P 3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret 3,4 Q Switch Only, Maintained Contacts .058 Dia, Round Q.C. R 3,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. 3 S Series Trip (Current) .060 Dia, Round Solder Turret T 3,4 Series Trip (Current) .058 Dia, Round Q.C. U 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 2 3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C. 3 3,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. 4 3,4 Series Trip (Current) .058 Dia, Round Q.C. 5 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 9 Series Trip (Current) Aux Switch .110 QC x .020 QC 5 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 12 DC Short 14 DC Medium 20 50/60Hz Instantaneous 22 50/60Hz Short 24 50/60Hz Medium 30 DC, 50/60Hz Instantaneous 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 62 50/60Hz Short, Hi-Inrush 64 50/60Hz Medium, Hi-Inrush 72 DC, Short,Hi-Inrush 74 DC,Medium, Hi-Inrush 92 DC, 50/60Hz Short, Hi-Inrush 94 DC, 50/60Hz Medium, Hi-Inrush Notes: 1 One actuator is located in the center of each multi-pole breaker. 2 For Switch Only circuits, select Current Coil Rating from the above chart: 3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only circuits, & is not available in single pole illuminated breakers, or Back Connected Screw or Push-in Stud terminals. 4 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-2 (tin plated). 5 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K, 1/4 WATT, external resistors must be supplied by customer. 6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel. 7 For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with electrical characteristics: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values. 8 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp. 9 Other colors available. Consult factory. 10 TUV 20A, VDE 15A. UL Recognized and CSA Accepted to 30 amps. Screw Terminals or Push-in Stud recommended above 20 amps. 11 TUV or VDE Certified must have I-O or Dual Legends. Legend required on Visi-Rocker breakers. 12 30 amp rating not available with delay’s 30, 32, 34, 92 or 94. 13 Screw Terminals are VDE certified only with use of ring terminal attached to wire. 14 Terminal code A available with circuit codes A & B only. 15 Printed circuit board available with UL recognized approval only. 16 Auxiliary switch (flat Q.C.) available with UL recognized approvals only. 7 TERMINAL 1 Push-On 0.250 Tab (Q.C.) 2 10 Screw 8-32 with Upturned Lugs 10 3 Screw 8-32 (Bus Type) 8 ROCKER ILLUMINATION Non-illuminated Neon 5 without resistor, 120VAC/250VAC LED 7, 8 without resistor with resistor, 4-8 VDC with resistor, 9-16 VDC A 14 P 15 A Neon B Red D E F Push-In Stud Printed Circuit Board Green Glow 8 C Green G H J Amber K L M 9 ACTUATOR & LEGEND COLOR Solid Color Actuator Legend 1 White Black 2 Black White 3 Red White 4 Green White 5 Blue White 6 Yellow Black 7 Gray Black 8 Orange Black Visi-Rocker 6 Visi & Legend (remainder of rocker same color as bezel) 1 White 2 Black 3 Red 4 Green 5 Blue 6 Yellow 7 Gray 8 Orange Illuminated 8 Actuator Legend A Clear White B Red Transparent White C Green Transparent White D Amber Transparent White E Smoke Gray Transparent White F White Translucent Black 10 LEGEND 11 1 No Legend 2 ON - OFF Vertical 3 ON - OFF Horizontal 4 5 6 7 I - O Vertical I - O Horizontal Dual Vertical Dual Horizontal 11 BEZEL COLOR / STYLE 9 Color without Rockerguard with Rockerguard White A1 Black B2 Gray G7 12 AGENCY APPROVAL 10 C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 18 | M-Series Circuit Breaker - Rocker UL489A/UL Recognized – Ordering Scheme M A 1 1 Series 2 Actuator B 14 4 Circuit 3 Poles 5 Frequency & Delay 620 6 Current Rating 1 7 Terminal A 1 6 9 8 Illumination Actuator Color 10 Legend 7 TERMINAL 1 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 with Upturned Lugs 3 Screw 8-32 (Bus Type) 1 SERIES M 2 ACTUATOR 1 Non-Illuminated Two Color single color Visi-Rocker A AngledD Indicate ON B Flat E Indicate OFF illuminated single color F Angled G Flat 3 POLES 1 One 4 CIRCUIT 2 without Auxiliary Switch B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: M Series Trip (Current) Aux Switch .110 QC x .020 QC S3 Series Trip (Current) .060 Dia, Round Solder Turret 3,4 T Series Trip (Current) .058 Dia, Round Q.C. U 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 4 3,4 Series Trip (Current) .058 Dia, Round Q.C. 5 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 9 Series Trip (Current) Aux Switch .110 QC x .020 QC 5 FREQUENCY & DELAY 10 DC Instantaneous 12 DC Short 14 72 74 DC Medium DC, Short,Hi-Inrush DC,Medium, Hi-Inrush 6 CURRENT RATING (AMPERES) 8 ROCKER ILLUMINATION Non-illuminated Neon 4 without resistor, 120VAC/250VAC LED 7, 8 without resistor with resistor, 4-8 VDC with resistor, 9-16 VDC 2 A Neon B Red D E F 11 Bezel Color A 11 P 12 J 12 Agency Approval Push-In Stud Printed Circuit Board Green Glow 8 C Green G H J Amber K L M 9 ACTUATOR & LEGEND COLOR Solid Color Actuator Legend 1 White Black 2 Black White 3 Red White 4 Green White 5 Blue White 6 Yellow Black 7 Gray Black 8 Orange Black 6 Visi-Rocker Visi & Legend (remainder of rocker same color as bezel) 1 White 2 Black 3 Red 4 Green 5 Blue 6 Yellow 7 Gray 8 Orange 7 Illuminated Actuator Legend A Clear White B Red Transparent White C Green Transparent White D Amber Transparent White E Smoke Gray Transparent White F White Translucent Black CODEAMPERES 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 5171.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 61010.000 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 Notes: 1 One actuator is located in the center of each multi-pole breaker. 2 One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip & Switch Only circuits, and is not available in single pole illuminated breakers, or with Back Connected Screw or Push-in Stud terminals. 3 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-1 (tin plated). 4 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K, 1/4 WATT, external resistors must be supplied by customer. 5 For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values. 6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel. 7 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp. 8 Other colors available. Consult factory. 9 TUV Certified to 25 amps. UL Recognized, CSA Accepted and UL489A Listed to 30 amps. Screw Terminals recommended above 20 amps. 10 UL489A Listed must have ON-OFF or Dual legends. TUV Certified approvals must have I - O or Dual legends. 11 Terminal code A available with circuit codes A & B only. 12 Printed circuit board available with UL recognized approval only. 13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only. 10 LEGEND 10 1 No Legend (Single Color or Illuminated Rocker Options Only) 2 ON - OFF Vertical 3 ON - OFF Horizontal 4 I - O Vertical 5 I - O Horizontal 6 Dual Vertical 7 Dual Horizontal 11 BEZEL COLOR / STYLE 8 Color without Rockerguard with Rockerguard White A1 Black B2 Gray G7 12 AGENCY APPROVAL 9 J UL489A Listed & TUV Certified M UL Recognized & CSA Accepted N TUV Certified, UL Recognized & CSA Accepted T UL489A Listed Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams | 19 Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 20 | M-Series Circuit Breaker - Rocker – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ± 0.20 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com M-Series Circuit Breaker - Rocker – Supplementary Diagrams | 21 Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 22 | M-Series, Circuit Breaker - Time Delay Values , Notes: 1 2 3 4 Delay Curves 12,14, 22, 24, 32, 34, 62, 64, 72, 74, 92, 94: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve. Delay Curves 10, 20, 30: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 18 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads. Instantaneous Dual Rated AC/DC Short Short D2 Medium Medium D4 Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Reps & Contact | 23 Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: [email protected] Northern Region Sales Office: [email protected] Southeast Region Sales Office: [email protected] Midwest Region Sales Office: [email protected] West Region Sales Office: [email protected] Latin America Sales Office: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China: [email protected] Shanghai, China: [email protected] Pune, India: [email protected] Kaohsiung, Taiwan: [email protected] Yokohama, Japan: [email protected] Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: [email protected] Germany: [email protected] France: [email protected] www.carlingtech.com REV_02_2016