E-Series Circuit Breaker Datasheet

E-Series
Circuit Breaker
The E-Series hydraulic/magnetic circuit breaker is ideally suited
for higher current and voltage applications. It is UL listed
and CSA certified for branch circuit protection, which does
not require a fuse back up. It is also UL recognized and CSA
certified as a supplementary protector and as a manual motor
controller.
Its physical features include front and back mounting, screw
and stud terminals and heavy duty box wire connectors
for solid wire or a pressure plate connector for standard
wire. The E-series is available with handle actuators and can
be configured as .1-125 amps, up to 600VAC or 125VDC,
with choice of time delays, actuator colors and 1 to 6 poles
configuration. Additionally, a Power Selector device is also
available.
Product Highlights:
ŠŠ UL listed and CSA certified
ŠŠ Certified for circuit branch protection
ŠŠ Recognized as a supplementary protector and as a manual
motor controller
ŠŠ Optional power selector device
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
Typical Applications:
ŠŠ Ideal for higher current and voltage applications
ŠŠ Renewable energy systems
ŠŠ Military
ŠŠ Industrial controls
ŠŠ Generators
2 | E-Series Circuit Breaker - General Specifications
Mechanical
Electrical
Maximum Voltage
600VAC 50/60 Hz, 125VDC (See Table A)
Current Ratings
Standard current coils: 0.100, 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, 70.0 & 100 Amp.
Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A 65VDC; 0.5A 80VDC, 0.1A 125VAC
(with gold contacts).
Insulation Resistance
Minimum of 100 Megohms at 500 VDC.
Dielectric Strength
UL, CSA: 2200 V 50/60 Hz for one minute between all electrically isolated terminals. E-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805.
Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker.
Endurance
10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage.
Trip Free
All E-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position.
Trip Indication
The operating Handle moves positively to the OFF position when an overload causes the breaker to trip.
Physical
Number of Poles
Mounting
Connectors, Box Type
Internal Circuit Configuration
Weight
Standard Colors
1-6
A 3” minimum spacing must be
provided between the circuit breaker arc venting area on back
connected E-Series circuit breakers and grounded obstructions. E-Series circuit breakers must be mounted on a vertical surface.
Front connected E-Series circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum.
Series and Switch Only, (with or
without auxiliary switch). Shunt with current coils.
Approximately 252 grams/pole (Approximately 9 ounces/pole)
Housing-Black; Actuator - See Ordering Scheme.
Environmental
Designed in accordance with requirements of specification
MIL PRF-55629 & MIL-STD-202G as follows:
Pulse Tolerance Curves
Time Delay Curves
62, 64 & 66
(100 Amps Max.)
Time Delay Curves
22, 24 & 26 (100 Amps Max.)
Shock
Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”.
Vibration
Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C, Test Condition A.
Moisture Resistance
Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.
Salt Spray
Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C).
Operating Temperature -40° C to +85° C
*Manufacturer reserves the right to change product specification without prior notice.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
E-Series Circuit Breaker - General Specifications | 3
Agency Certifications
UL Recognized
UL Standard 1077
CSA Accepted
Component Supplementary
Protector (Class 3215 30, File
047848 0 000)
CSA Standard C22.2 No. 235
Component Recognition Program
as Manual Motor Controls (Guide
NLRV2, File E135367)
CSA Certified
Circuit Breaker Molded Case
(Class 1432 01, File 093910),
CSA Standard C22.2 No. 5.1 - M
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
TUV Certified
EN60934 under License No.
R72031056
VDE Certified
EN60934, VDE 0642 under File
No. 10537
Component Recognition Program
as Protectors, Supplementary
(Guide QVNU2, File E75596)
UL Standard 1500
UL Listed
UL Standard 489
Circuit Breakers, Molded Case
(Guide DIVQ, File E129899)
Electrical Tables
Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case
Circuit Breaker.
E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS
VOLTAGE
CIRCUIT
CONFIGURATION
SERIES
CURRENT RATING
INTERRUPTING
CAPACITY (AMPS)
HIGH
INTERRUPTING
CAPACITY
WITHOUT BACKUP
(AMPS)
FUSE
MAX.
RATING
FREQUENCY
PHASE
80
125
125
DC
DC
DC
-------
0.10 - 100
0.10 - 100
0.10 - 125
5,000
5,000
10,000
50,000
10,000
---
120
240
240
120 / 240
120 / 240
120 / 240
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
1
1
1
1
1
1
0.10 - 125
0.10 - 30
31 - 100
0.10 - 30
31 - 100
101 - 125
10,000
5,000
5,000
5,000
5,000
10,000
--10,000
10,000
-----
240
50 / 60
3
0.10 - 100
5,000
---
FULL LOAD AMPS
Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary
Protector.
VOLTAGE
CIRCUIT
CONFIGURATION
SERIES &
SHUNT
SWITCH
ONLY
E -SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS
CURRENT RATING
SHORT CIRCUIT CAPACITY (AMPS)
APPLICATION CODES
UL/CSA
MAX.
RATING
FREQUENCY
PHASE
FULL LOAD
GENERAL
AMPS
PURPOSE AMPS
125
125
150
160
DC
DC
DC
DC
---------
0.02 - 100
----0.02 - 100
150 / 300
120 / 240
DC
50 / 60
--1
240
250
50 / 60
50 / 60
277
WITH BACKUP
FUSE3
WITHOUT
BACKUP FUSE
UL
CSA
--101 - 120
0.02 - 125
---
---------
5,000
5,000
5,000
5,000
TC1,2, OL1, U1
TC1,2, OL0, U1
TC1, OL0, U3
TC1,2, OL1, U1
TC1,2, OL1, U1
TC1,2, OL0, U1
TC1, OL0, U3
TC1,2, OL1, U1
0.02 - 100
---
--0.02 - 100
-----
5,000
5,000
TC1,2, OL1, U1 TC1,2, OL1, U1
TC1,2, OL0, U1 TC1,2, OL0, U1
1
1
0.02 - 100
0.02 - 100
-----
50 / 60
1
0.02 - 100
---
--10,000
---
5,000
--5,000
TC1,2, OL1, U1 TC1,2, OL1, U1
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1,2, OL1, U1 TC1,2, OL1, U1
480
50 / 60
1&3
0.02 - 100
---
10,000
10,000
-----
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1,2, OL1, C1 TC1,2, OL1, C1
480 1
600
50 / 60
50 / 60
1&3
1&3
0.02 - 50
0.02 - 100
-----
10,000
10,000
-----
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1,2, OL1, C1 TC1,2, OL1, C1
600 2
125
160
DC
---
---
0.02 - 125
---
5,000
DC
DC
-----
0.02 - 120
0.02 - 100
240
277
480
50 / 60
50 / 60
50 / 60
1
1
1&3
0.02 - 100
0.02 - 100
0.02 - 100
600
50 / 60
1&3
0.02 - 100
TC1, OL0, U3
TC1, OL0, U3
Table B Notes:
1 Per pole opposite polarity rating - Delta Configuration.
2 4 Poles connected in series
3 Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse
rated 15A minimum and no more than 4 times full load amp rating and
not to exceed 225A.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
4 | E-Series Circuit Breaker - General Specifications
Electrical Tables
Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a
Component Supplementary Protector.
E -SERIES TABLE C: COMPONENT SUPPLEMENTARY PROTECTORS WITH VDE
CURRENT RATING
VOLTAGE
CIRCUIT
CONFIGURATION
SHORT CIRCUIT CAPACITY (AMPS)
UL/CSA
MAX.
FREQUENCY PHASE FULL LOAD AMPS WITH BACKUP
RATING
FUSE1
125
DC
---
0.1 - 100
---
WITHOUT
BACKUP
FUSE
WITHOUT
BACKUP
FUSE
5,000
5,000
SERIES &
240
50 / 60
1&3
0.1 - 100
---
5,000
5,000
SHUNT
415
50 / 60
1&3
0.1 - 100
10,000
---
4,000
SWITCH ONLY
125
DC
---
0.1 - 125
240
50 / 60
1&3
0.1 - 100
415
50 / 60
1&3
0.1 - 100
APPLICATION CODES
VDE (Icn)
UL
CONSTRUCTION NOTES
CSA
TC1,2, OL1, U1 TC1,2, OL1, U1
1 or 2 Poles
1 - 5 Poles. Up to 4
TC1,2, OL1, U1 TC1,2, OL1, U1 Current Poles, 1 Voltage
Pole
2 - 5 Poles. Up to 4
TC1,2, OL1, C1 TC1,2, OL1, C1 Current Poles, 1 Voltage
Pole
Table C Notes:
1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225 amps.
Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
E SERIES TABLE D : UL1500 (Marine Ignition Protection)
VOLTAGE
CIRCUIT
CONFIGURATION
SERIES
MAX.
RATING
FREQUENCY
65
125
250
DC
50 / 60
50 / 60
CURRENT RATING
SHORT CIRCUIT
CAPACITY (AMPS)
FULL LOAD AMPS
WITHOUT BACKUP
FUSE
UL
CSA
0.02 - 100
0.02 - 100
0.02 - 100
5,000
1,500
1,500
TC1,2,OL1,U1
TC1,2,OL1,U1
TC1,2,OL1,U1
TC1,2,OL1,U1
TC1,2,OL1,U1
TC1,2,OL1,U1
PHASE
--1
1
APPLICATION CODES
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
E-Series Handle UL Recognized – Ordering Scheme | 5
E A 2
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Auxiliary
Switch
24
6
Frequency
& Delay
450
7
Current Rating
Handle, one per pole
3 POLES1
1
One
2Two
3Three
4Four
4 CIRCUIT2
Switch Only (no coil)
Series Trip (current)
Series Trip (voltage)
Shunt Trip (current)
5 AUXILIARY SWITCH4
0
2
3
4
without Auxiliary Switch
S.P.D.T. 0.110 Q.C. Terminals
S.P.D.T. 0.139 Solder Lug
S.P.D.T. 0.110 Q.C. Terminals
(Gold Contacts)
6 FREQUENCY & DELAY
033 105 12
14
16
205 22
24
26
30 32
DC 50/60Hz, Switch Only
DC Instantaneous
DC Short
DC Medium
DC Long
50/60Hz Instantaneous
50/60Hz Short
50/60Hz Medium
50/60Hz Long
DC, 50/60Hz Instantaneous
DC, 50/60Hz Short
5Five
6Six
E
F
G
Shunt Trip (voltage)
Relay Trip (current)
Relay Trip (voltage)
6
7
8
9
S.P.D.T. 0.110 Q.C. Terminals
S.P.D.T. 0.110 Q.C. Terminals
(Gold Contacts)
S.P.D.T. 0.187 Q.C. Terminals
S.P.D.T. 0.187 Q.C. Terminals
10
Mounting/
Barriers
9 ACTUATOR COLOR & LEGEND13
Actuator Color
I-O
ON-OFF
White
A
B
Black
C
D
Red
F
G
Green
H
J
Blue
K
L
Yellow
M
N
Gray
P
Q
Orange
R
S
34
DC, 50/60Hz Medium
36
DC, 50/60Hz Long
62 50/60Hz Short, Hi-Inrush
64 50/60Hz Medium, Hi-Inrush
66 50/60Hz Long, Hi-Inrush
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
76 DC, Long, Hi-Inrush
DC, 50/60Hz Short, Hi-Inrush
926
DC, 50/60Hz Medium,
946
Hi-Inrush
6
DC, 50/60Hz Long, Hi-Inrush
96
11
Maximum
Application
Rating
12
Agency
Approval
Notes:
1 VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory.
2 Switch Only & Series Trip construction available w/either front or back connected terminals.
Shunt construction available w/back connected terminals, (Terminal Codes 1 & 2) only. Circuit Codes B,C & D are VDE approved.
3 Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps, select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125 amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a protected pole.
Legend Color
Black
White
White
White
White
Black
Black
Black
BACK CONNECTED (FRONT MOUNTED ONLY)
Mounting Inserts
A
6-32
B
ISO M3
FRONT CONNECTED (BACK MOUNTED ONLY)14
Back Mounting Foot Type Front Mounting Inserts (Optional Use)
CShort
6-32
D
Short
ISO M3
ELong
6-32
F
Long
ISO M3
AMPERES
020 0.020
235 0.350
430 3.000
614 14.000
025 0.025
240 0.400
435 3.500
615 15.000
030 0.030
245 0.450
440 4.000
616 16.000
035 0.035
250 0.500
445 4.500
617 17.000
040 0.040
255 0.550
450 5.000
618 18.000
045 0.045
260 0.600
455 5.500
620 20.000
050 0.050
265 0.650
460 6.000
622 22.000
055 0.055
270 0.700
465 6.500
624 24.000
060 0.060
275 0.750
470 7.000
625 25.000
065 0.065
280 0.800
475 7.500
630 30.000
070 0.070
285 0.850
480 8.000
635 35.000
075 0.075
290 0.900
485 8.500
640 40.000
080 0.080
295 0.950
490 9.000
650 50.000
085 0.085
410 1.000
495 9.500
660 60.000
090 0.090
512 1.250
610 10.000
670 70.000
090 0.095
415 1.500
710 10.500
680 80.000
210 0.100
517 1.750
611 11.000
690 90.000
215 0.150
420 2.000
711 11.500
810 100.000
220 0.200
522 2.250
612 12.000
811 110.000
225 0.250
425 2.500
712 12.500
812 120.000
230 0.300
527 2.750
613 13.000
9128 125.000
5
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)
A06 6 DC, 5 DC
A65 65 DC, 55 DC
J48 48 AC, 40 AC
A12 12 DC, 10 DC
B25 125 DC, 100 DC
J65 65 AC, 55 AC
A18 18 DC, 15 DC
J06
6 AC, 5 AC
K20 120 AC, 65 AC
A24 24 DC, 20 DC
J12 12 AC, 10 AC
L40 240 AC, 130 AC
A32 32 DC, 25 DC
J18 18 AC, 15 AC
A48 48 DC, 40 DC
J24 24 AC, 20 AC
Dual
1
2
3
4
5
6
7
8
10 MOUNTING/BARRIERS
7 CURRENT RATING (AMPERES) 7
CODE
9
Actuator
Color
BACK CONNECTED (FRONT MOUNTED ONLY)
MAX. RATING
1 9
10-32 Stud (All Terminals)
50 A
2 9
1/4-20 Stud (All Terminals)
120 A
9
A
M5 Stud (Line & Load)
50 A
B 9
M6 Stud (Line & Load)
100 A
FRONT CONNECTED (BACK MOUNTED ONLY)
MAX. RATING
310
Box Wire Connector (Line & Load)
100 A
C11
Box Wire Connector w/ Pressure Plate (Line & Load)
100 A
4
10-32 Screw (Line & Load)
50 A
D
M5 Screw (Line & Load)
50 A
5
10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load)
50 A
E
M5 “Bus-Type” Screw (Line), 10-32 Screw (Load)
50 A
10
6 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load)
100 A
10-32 “Bus-Type” Screw (Line), Box Wire Connector
F11
w/ Pressure Plate (Load)
100 A
7
1/4-20 Screw (Line & Load)
100 A
G
M6 Screw (Line & Load)
100 A
8
1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load)
100 A
H
M6 “Bus-Type” Screw (Line), M6 Screw (Load)
100 A
10
9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A
11
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector
J
w/ Pressure Plate (Load)
100 A
2 ACTUATOR
A3 B
C
D
8
Terminal
C B
8 TERMINAL12
1 SERIES
E
A
1 2 A
11 MAXIMUM APPLICATION RATING15
A
65 VDC, 120 A
G16
B
125 VDC, 120 A
H16
C
120/240 VAC, 100 A
J16
D
240 VAC, 100 A
L16
E16
277/480 VAC, 100 A
T
F
277 VAC, 100 A
W16
600 VAC, 100 A
480 VAC, 100 A
415 VAC, 100 A
160 VDC, 100 A
125 VDC/240 VAC, 100 A
125 VDC/415 VAC, 100 A
12 AGENCY APPROVAL
UL 1077 / UL508 Recognized & CSA Accepted
B
UL 1077 Recognized, CSA Accepted, & VDE Certified
D
4
5
6
7
8
9
10
11
12
13
14
15
16
Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE approval on Auxilary Switch Codes 0,2,3 & 4 only.
Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to a protected pole.
Frequency & Delay Codes 92,94 & 96 are not VDE Certified.
Current Coil Ratings 0.100 - 100 ams are VDE Certified.
125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B).
An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement.
Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire.
Box Wire Connector with Pressure Plate for stranded wire, consult factory for details.
Terminal Codes A,B,D,E,G & H are not VDE Certified.
VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles.
Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting.
Application ratings B,D,J,T & W are available with VDE.
415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
6 | E-Series Handle UL Listed – Ordering Scheme
E A 2
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Auxiliary
Switch
24
6
Frequency
& Delay
2 ACTUATOR
Handle, one per pole
3 POLES1
1
One
2Two
3Three
4Four
4 CIRCUIT2
B
Series Trip (current)
5 AUXILIARY SWITCH4
0
2
3
4
without Auxiliary Switch
S.P.D.T. 0.110 Q.C. Terminals
S.P.D.T. 0.139 Solder Lug
S.P.D.T. 0.110 Q.C. Terminals
(Gold Contacts)
6 FREQUENCY & DELAY
105 12
14
16
205 22
24
26
30 32
34
DC Instantaneous
DC Short
DC Medium
DC Long
50/60Hz Instantaneous
50/60Hz Short
50/60Hz Medium
50/60Hz Long
DC, 50/60Hz Instantaneous
DC, 50/60Hz Short
DC, 50/60Hz Medium
5Five
6Six
C3
6
7
8
9
Series Trip (voltage)
S.P.D.T. 0.110 Q.C. Terminals
S.P.D.T. 0.110 Q.C. Terminals
(Gold Contacts)
S.P.D.T. 0.187 Q.C. Terminals
S.P.D.T. 0.187 Q.C. Terminals
36
DC, 50/60Hz Long
62 50/60Hz Short, Hi-Inrush
64 50/60Hz Medium, Hi-Inrush
66 50/60Hz Long, Hi-Inrush
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
76 DC, Long, Hi-Inrush
DC, 50/60Hz Short, Hi-Inrush
926
6
DC, 50/60Hz Medium,
94
Hi-Inrush
DC, 50/60Hz Long, Hi-Inrush
966
7 CURRENT RATING (AMPERES) 7
CODE
7
Current Rating
1 2 A
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
C C
11
Maximum
Application
Rating
12
Agency
Approval
8 TERMINAL7
1 SERIES
E
A
450
AMPERES
020 0.020
235 0.350
430 3.000
614 14.000
025 0.025
240 0.400
435 3.500
615 15.000
030 0.030
245 0.450
440 4.000
616 16.000
035 0.035
250 0.500
445 4.500
617 17.000
040 0.040
255 0.550
450 5.000
618 18.000
045 0.045
260 0.600
455 5.500
620 20.000
050 0.050
265 0.650
460 6.000
622 22.000
055 0.055
270 0.700
465 6.500
624 24.000
060 0.060
275 0.750
470 7.000
625 25.000
065 0.065
280 0.800
475 7.500
630 30.000
070 0.070
285 0.850
480 8.000
635 35.000
075 0.075
290 0.900
485 8.500
640 40.000
080 0.080
295 0.950
490 9.000
650 50.000
085 0.085
410 1.000
495 9.500
660 60.000
090 0.090
512 1.250
610 10.000
670 70.000
090 0.095
415 1.500
710 10.500
680 80.000
210 0.100
517 1.750
611 11.000
690 90.000
215 0.150
420 2.000
711 11.500
810 100.000
220 0.200
522 2.250
612 12.000
811 110.000
225 0.250
425 2.500
712 12.500
812 120.000
230 0.300
527 2.750
613 13.000
9128 125.000
5
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)
A06 6 DC, 5 DC
A65 65 DC, 55 DC
J48 48 AC, 40 AC
A12 12 DC, 10 DC
B25 125 DC, 100 DC
J65 65 AC, 55 AC
A18 18 DC, 15 DC
J06
6 AC, 5 AC
K20 120 AC, 65 AC
A24 24 DC, 20 DC
J12 12 AC, 10 AC
L40 240 AC, 130 AC
A32 32 DC, 25 DC
J18 18 AC, 15 AC
A48 48 DC, 40 DC
J24 24 AC, 20 AC
BACK CONNECTED (FRONT MOUNTED ONLY)
MAX. RATING
1 8
10-32 Stud (All Terminals)
50 A
8
2
1/4-20 Stud (All Terminals)
125 A
FRONT CONNECTED (BACK MOUNTED ONLY)
MAX. RATING
3 9
Box Wire Connector (Line & Load)
100 A
C10
Box Wire Connector w/ Pressure Plate (Line & Load)
100 A
4
10-32 Screw (Line & Load)
50 A
5
10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load)
50 A
6 9
10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load)
100 A
10-32 “Bus-Type” Screw (Line), Box Wire Connector
F10
w/ Pressure Plate (Load)
100 A
7
1/4-20 Screw (Line & Load)
125 A
8
1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load)
100 A
9 9
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A
10
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector
J
w/ Pressure Plate (Load)
100 A
9 ACTUATOR COLOR & LEGEND12
Actuator Color
Dual
ON-OFF
White
1
B
Black
2
D
Red
3
G
Green
4
J
Blue
5
L
Yellow
6
N
Gray
7
Q
Orange
8
S
Legend Color
Black
White
White
White
White
Black
Black
Black
10 MOUNTING/BARRIERS
BACK CONNECTED (FRONT MOUNTED ONLY)
Mounting Inserts
A
6-32
B
ISO M3
FRONT CONNECTED (BACK MOUNTED ONLY)11
Back Mounting Foot Type Front Mounting Inserts (Optional Use)
CShort
6-32
D
Short
ISO M3
ELong
6-32
F
Long
ISO M3
11 MAXIMUM APPLICATION RATING
1
120 VAC
B
125 VDC, 120 A
C13
120/240 VAC, 100 A
D
240 VAC, 100 A
12 AGENCY APPROVAL
UL 489 Listed & CSA Certified
C
UL 489 Listed, CSA Certified, & VDE Certified
F
Notes:
1 Standard multi-pole units identical poles except when specifying auxiliary switch (see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only.
2 Series Trip construction available w/either front or back connected terminals. 3 Series Trip construction with a voltage coil is not available as a single pole unit and must be tied to a protected pole.
4 On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when
auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only.
5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20.
6 Frequency & Delay Codes 92, 94 & 96 are not VDE Certified.
7 Current Ratings under 0.100 amps are not VDE Certified .
8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud (Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement.
9 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire.
10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details.
11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mouning inserts normally supplied. However, terminal connections must be made prior to mounting.
12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles.
13 Not available with VDE Certification.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
E-Series Handle – Circuit & Terminal Diagrams | 7
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
3 0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long.
4 51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
8 | E-Series Handle (Back Connected) – Form & Fit Drawings
Notes:
1 1/4 -20 stud terminal in Series Trip circuit configuration shown.
2 A 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions.
3 All dimensions are in inches [millimeters].
4 Tolerance ±.020 [.51] unless otherwise specified.
5 Circuit breakers must be mounted on vertical surface.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
E-Series Handle (Front Connected) – Form & Fit Drawings | 9
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
3 Box wire connector terminal in Series Trip circuit configuration shown.
4 Circuit breakers must be mounted on vertical surface.
REV_CB_E_01_2014
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com