E-Series Circuit Breaker The E-Series hydraulic/magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL recognized and CSA certified as a supplementary protector and as a manual motor controller. Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle actuators and can be configured as .1-125 amps, up to 600VAC or 125VDC, with choice of time delays, actuator colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available. Product Highlights: UL listed and CSA certified Certified for circuit branch protection Recognized as a supplementary protector and as a manual motor controller Optional power selector device Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: [email protected] • www.carlingtech.com Typical Applications: Ideal for higher current and voltage applications Renewable energy systems Military Industrial controls Generators 2 | E-Series Circuit Breaker - General Specifications Mechanical Electrical Maximum Voltage 600VAC 50/60 Hz, 125VDC (See Table A) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, 70.0 & 100 Amp. Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A 65VDC; 0.5A 80VDC, 0.1A 125VAC (with gold contacts). Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one minute between all electrically isolated terminals. E-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trip Free All E-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. Physical Number of Poles Mounting Connectors, Box Type Internal Circuit Configuration Weight Standard Colors 1-6 A 3” minimum spacing must be provided between the circuit breaker arc venting area on back connected E-Series circuit breakers and grounded obstructions. E-Series circuit breakers must be mounted on a vertical surface. Front connected E-Series circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Series and Switch Only, (with or without auxiliary switch). Shunt with current coils. Approximately 252 grams/pole (Approximately 9 ounces/pole) Housing-Black; Actuator - See Ordering Scheme. Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Pulse Tolerance Curves Time Delay Curves 62, 64 & 66 (100 Amps Max.) Time Delay Curves 22, 24 & 26 (100 Amps Max.) Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com E-Series Circuit Breaker - General Specifications | 3 Agency Certifications UL Recognized UL Standard 1077 CSA Accepted Component Supplementary Protector (Class 3215 30, File 047848 0 000) CSA Standard C22.2 No. 235 Component Recognition Program as Manual Motor Controls (Guide NLRV2, File E135367) CSA Certified Circuit Breaker Molded Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection TUV Certified EN60934 under License No. R72031056 VDE Certified EN60934, VDE 0642 under File No. 10537 Component Recognition Program as Protectors, Supplementary (Guide QVNU2, File E75596) UL Standard 1500 UL Listed UL Standard 489 Circuit Breakers, Molded Case (Guide DIVQ, File E129899) Electrical Tables Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit Breaker. E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION SERIES CURRENT RATING INTERRUPTING CAPACITY (AMPS) HIGH INTERRUPTING CAPACITY WITHOUT BACKUP (AMPS) FUSE MAX. RATING FREQUENCY PHASE 80 125 125 DC DC DC ------- 0.10 - 100 0.10 - 100 0.10 - 125 5,000 5,000 10,000 50,000 10,000 --- 120 240 240 120 / 240 120 / 240 120 / 240 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 1 1 1 1 1 1 0.10 - 125 0.10 - 30 31 - 100 0.10 - 30 31 - 100 101 - 125 10,000 5,000 5,000 5,000 5,000 10,000 --10,000 10,000 ----- 240 50 / 60 3 0.10 - 100 5,000 --- FULL LOAD AMPS Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. VOLTAGE CIRCUIT CONFIGURATION SERIES & SHUNT SWITCH ONLY E -SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES UL/CSA MAX. RATING FREQUENCY PHASE FULL LOAD GENERAL AMPS PURPOSE AMPS 125 125 150 160 DC DC DC DC --------- 0.02 - 100 ----0.02 - 100 150 / 300 120 / 240 DC 50 / 60 --1 240 250 50 / 60 50 / 60 277 WITH BACKUP FUSE3 WITHOUT BACKUP FUSE UL CSA --101 - 120 0.02 - 125 --- --------- 5,000 5,000 5,000 5,000 TC1,2, OL1, U1 TC1,2, OL0, U1 TC1, OL0, U3 TC1,2, OL1, U1 TC1,2, OL1, U1 TC1,2, OL0, U1 TC1, OL0, U3 TC1,2, OL1, U1 0.02 - 100 --- --0.02 - 100 ----- 5,000 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 TC1,2, OL0, U1 TC1,2, OL0, U1 1 1 0.02 - 100 0.02 - 100 ----- 50 / 60 1 0.02 - 100 --- --10,000 --- 5,000 --5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, U1 TC1,2, OL1, U1 480 50 / 60 1&3 0.02 - 100 --- 10,000 10,000 ----- TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 480 1 600 50 / 60 50 / 60 1&3 1&3 0.02 - 50 0.02 - 100 ----- 10,000 10,000 ----- TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 600 2 125 160 DC --- --- 0.02 - 125 --- 5,000 DC DC ----- 0.02 - 120 0.02 - 100 240 277 480 50 / 60 50 / 60 50 / 60 1 1 1&3 0.02 - 100 0.02 - 100 0.02 - 100 600 50 / 60 1&3 0.02 - 100 TC1, OL0, U3 TC1, OL0, U3 Table B Notes: 1 Per pole opposite polarity rating - Delta Configuration. 2 4 Poles connected in series 3 Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225A. 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com 4 | E-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a Component Supplementary Protector. E -SERIES TABLE C: COMPONENT SUPPLEMENTARY PROTECTORS WITH VDE CURRENT RATING VOLTAGE CIRCUIT CONFIGURATION SHORT CIRCUIT CAPACITY (AMPS) UL/CSA MAX. FREQUENCY PHASE FULL LOAD AMPS WITH BACKUP RATING FUSE1 125 DC --- 0.1 - 100 --- WITHOUT BACKUP FUSE WITHOUT BACKUP FUSE 5,000 5,000 SERIES & 240 50 / 60 1&3 0.1 - 100 --- 5,000 5,000 SHUNT 415 50 / 60 1&3 0.1 - 100 10,000 --- 4,000 SWITCH ONLY 125 DC --- 0.1 - 125 240 50 / 60 1&3 0.1 - 100 415 50 / 60 1&3 0.1 - 100 APPLICATION CODES VDE (Icn) UL CONSTRUCTION NOTES CSA TC1,2, OL1, U1 TC1,2, OL1, U1 1 or 2 Poles 1 - 5 Poles. Up to 4 TC1,2, OL1, U1 TC1,2, OL1, U1 Current Poles, 1 Voltage Pole 2 - 5 Poles. Up to 4 TC1,2, OL1, C1 TC1,2, OL1, C1 Current Poles, 1 Voltage Pole Table C Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225 amps. Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. E SERIES TABLE D : UL1500 (Marine Ignition Protection) VOLTAGE CIRCUIT CONFIGURATION SERIES MAX. RATING FREQUENCY 65 125 250 DC 50 / 60 50 / 60 CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) FULL LOAD AMPS WITHOUT BACKUP FUSE UL CSA 0.02 - 100 0.02 - 100 0.02 - 100 5,000 1,500 1,500 TC1,2,OL1,U1 TC1,2,OL1,U1 TC1,2,OL1,U1 TC1,2,OL1,U1 TC1,2,OL1,U1 TC1,2,OL1,U1 PHASE --1 1 APPLICATION CODES 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com E-Series Handle UL Recognized – Ordering Scheme | 5 E A 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Auxiliary Switch 24 6 Frequency & Delay 450 7 Current Rating Handle, one per pole 3 POLES1 1 One 2Two 3Three 4Four 4 CIRCUIT2 Switch Only (no coil) Series Trip (current) Series Trip (voltage) Shunt Trip (current) 5 AUXILIARY SWITCH4 0 2 3 4 without Auxiliary Switch S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.139 Solder Lug S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) 6 FREQUENCY & DELAY 033 105 12 14 16 205 22 24 26 30 32 DC 50/60Hz, Switch Only DC Instantaneous DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Short 50/60Hz Medium 50/60Hz Long DC, 50/60Hz Instantaneous DC, 50/60Hz Short 5Five 6Six E F G Shunt Trip (voltage) Relay Trip (current) Relay Trip (voltage) 6 7 8 9 S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) S.P.D.T. 0.187 Q.C. Terminals S.P.D.T. 0.187 Q.C. Terminals 10 Mounting/ Barriers 9 ACTUATOR COLOR & LEGEND13 Actuator Color I-O ON-OFF White A B Black C D Red F G Green H J Blue K L Yellow M N Gray P Q Orange R S 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long 62 50/60Hz Short, Hi-Inrush 64 50/60Hz Medium, Hi-Inrush 66 50/60Hz Long, Hi-Inrush 72 DC, Short,Hi-Inrush 74 DC,Medium, Hi-Inrush 76 DC, Long, Hi-Inrush DC, 50/60Hz Short, Hi-Inrush 926 DC, 50/60Hz Medium, 946 Hi-Inrush 6 DC, 50/60Hz Long, Hi-Inrush 96 11 Maximum Application Rating 12 Agency Approval Notes: 1 VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory. 2 Switch Only & Series Trip construction available w/either front or back connected terminals. Shunt construction available w/back connected terminals, (Terminal Codes 1 & 2) only. Circuit Codes B,C & D are VDE approved. 3 Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps, select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125 amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a protected pole. Legend Color Black White White White White Black Black Black BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A 6-32 B ISO M3 FRONT CONNECTED (BACK MOUNTED ONLY)14 Back Mounting Foot Type Front Mounting Inserts (Optional Use) CShort 6-32 D Short ISO M3 ELong 6-32 F Long ISO M3 AMPERES 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 030 0.030 245 0.450 440 4.000 616 16.000 035 0.035 250 0.500 445 4.500 617 17.000 040 0.040 255 0.550 450 5.000 618 18.000 045 0.045 260 0.600 455 5.500 620 20.000 050 0.050 265 0.650 460 6.000 622 22.000 055 0.055 270 0.700 465 6.500 624 24.000 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 070 0.070 285 0.850 480 8.000 635 35.000 075 0.075 290 0.900 485 8.500 640 40.000 080 0.080 295 0.950 490 9.000 650 50.000 085 0.085 410 1.000 495 9.500 660 60.000 090 0.090 512 1.250 610 10.000 670 70.000 090 0.095 415 1.500 710 10.500 680 80.000 210 0.100 517 1.750 611 11.000 690 90.000 215 0.150 420 2.000 711 11.500 810 100.000 220 0.200 522 2.250 612 12.000 811 110.000 225 0.250 425 2.500 712 12.500 812 120.000 230 0.300 527 2.750 613 13.000 9128 125.000 5 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) A06 6 DC, 5 DC A65 65 DC, 55 DC J48 48 AC, 40 AC A12 12 DC, 10 DC B25 125 DC, 100 DC J65 65 AC, 55 AC A18 18 DC, 15 DC J06 6 AC, 5 AC K20 120 AC, 65 AC A24 24 DC, 20 DC J12 12 AC, 10 AC L40 240 AC, 130 AC A32 32 DC, 25 DC J18 18 AC, 15 AC A48 48 DC, 40 DC J24 24 AC, 20 AC Dual 1 2 3 4 5 6 7 8 10 MOUNTING/BARRIERS 7 CURRENT RATING (AMPERES) 7 CODE 9 Actuator Color BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 1 9 10-32 Stud (All Terminals) 50 A 2 9 1/4-20 Stud (All Terminals) 120 A 9 A M5 Stud (Line & Load) 50 A B 9 M6 Stud (Line & Load) 100 A FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 310 Box Wire Connector (Line & Load) 100 A C11 Box Wire Connector w/ Pressure Plate (Line & Load) 100 A 4 10-32 Screw (Line & Load) 50 A D M5 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A E M5 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 10 6 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 10-32 “Bus-Type” Screw (Line), Box Wire Connector F11 w/ Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 100 A G M6 Screw (Line & Load) 100 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A H M6 “Bus-Type” Screw (Line), M6 Screw (Load) 100 A 10 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 11 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector J w/ Pressure Plate (Load) 100 A 2 ACTUATOR A3 B C D 8 Terminal C B 8 TERMINAL12 1 SERIES E A 1 2 A 11 MAXIMUM APPLICATION RATING15 A 65 VDC, 120 A G16 B 125 VDC, 120 A H16 C 120/240 VAC, 100 A J16 D 240 VAC, 100 A L16 E16 277/480 VAC, 100 A T F 277 VAC, 100 A W16 600 VAC, 100 A 480 VAC, 100 A 415 VAC, 100 A 160 VDC, 100 A 125 VDC/240 VAC, 100 A 125 VDC/415 VAC, 100 A 12 AGENCY APPROVAL UL 1077 / UL508 Recognized & CSA Accepted B UL 1077 Recognized, CSA Accepted, & VDE Certified D 4 5 6 7 8 9 10 11 12 13 14 15 16 Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE approval on Auxilary Switch Codes 0,2,3 & 4 only. Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to a protected pole. Frequency & Delay Codes 92,94 & 96 are not VDE Certified. Current Coil Ratings 0.100 - 100 ams are VDE Certified. 125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B). An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement. Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. Terminal Codes A,B,D,E,G & H are not VDE Certified. VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles. Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. Application ratings B,D,J,T & W are available with VDE. 415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø. 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com 6 | E-Series Handle UL Listed – Ordering Scheme E A 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Auxiliary Switch 24 6 Frequency & Delay 2 ACTUATOR Handle, one per pole 3 POLES1 1 One 2Two 3Three 4Four 4 CIRCUIT2 B Series Trip (current) 5 AUXILIARY SWITCH4 0 2 3 4 without Auxiliary Switch S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.139 Solder Lug S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) 6 FREQUENCY & DELAY 105 12 14 16 205 22 24 26 30 32 34 DC Instantaneous DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Short 50/60Hz Medium 50/60Hz Long DC, 50/60Hz Instantaneous DC, 50/60Hz Short DC, 50/60Hz Medium 5Five 6Six C3 6 7 8 9 Series Trip (voltage) S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) S.P.D.T. 0.187 Q.C. Terminals S.P.D.T. 0.187 Q.C. Terminals 36 DC, 50/60Hz Long 62 50/60Hz Short, Hi-Inrush 64 50/60Hz Medium, Hi-Inrush 66 50/60Hz Long, Hi-Inrush 72 DC, Short,Hi-Inrush 74 DC,Medium, Hi-Inrush 76 DC, Long, Hi-Inrush DC, 50/60Hz Short, Hi-Inrush 926 6 DC, 50/60Hz Medium, 94 Hi-Inrush DC, 50/60Hz Long, Hi-Inrush 966 7 CURRENT RATING (AMPERES) 7 CODE 7 Current Rating 1 2 A 8 Terminal 9 Actuator Color 10 Mounting/ Barriers C C 11 Maximum Application Rating 12 Agency Approval 8 TERMINAL7 1 SERIES E A 450 AMPERES 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 030 0.030 245 0.450 440 4.000 616 16.000 035 0.035 250 0.500 445 4.500 617 17.000 040 0.040 255 0.550 450 5.000 618 18.000 045 0.045 260 0.600 455 5.500 620 20.000 050 0.050 265 0.650 460 6.000 622 22.000 055 0.055 270 0.700 465 6.500 624 24.000 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 070 0.070 285 0.850 480 8.000 635 35.000 075 0.075 290 0.900 485 8.500 640 40.000 080 0.080 295 0.950 490 9.000 650 50.000 085 0.085 410 1.000 495 9.500 660 60.000 090 0.090 512 1.250 610 10.000 670 70.000 090 0.095 415 1.500 710 10.500 680 80.000 210 0.100 517 1.750 611 11.000 690 90.000 215 0.150 420 2.000 711 11.500 810 100.000 220 0.200 522 2.250 612 12.000 811 110.000 225 0.250 425 2.500 712 12.500 812 120.000 230 0.300 527 2.750 613 13.000 9128 125.000 5 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) A06 6 DC, 5 DC A65 65 DC, 55 DC J48 48 AC, 40 AC A12 12 DC, 10 DC B25 125 DC, 100 DC J65 65 AC, 55 AC A18 18 DC, 15 DC J06 6 AC, 5 AC K20 120 AC, 65 AC A24 24 DC, 20 DC J12 12 AC, 10 AC L40 240 AC, 130 AC A32 32 DC, 25 DC J18 18 AC, 15 AC A48 48 DC, 40 DC J24 24 AC, 20 AC BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 1 8 10-32 Stud (All Terminals) 50 A 8 2 1/4-20 Stud (All Terminals) 125 A FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 3 9 Box Wire Connector (Line & Load) 100 A C10 Box Wire Connector w/ Pressure Plate (Line & Load) 100 A 4 10-32 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 6 9 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 10-32 “Bus-Type” Screw (Line), Box Wire Connector F10 w/ Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 125 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A 9 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 10 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector J w/ Pressure Plate (Load) 100 A 9 ACTUATOR COLOR & LEGEND12 Actuator Color Dual ON-OFF White 1 B Black 2 D Red 3 G Green 4 J Blue 5 L Yellow 6 N Gray 7 Q Orange 8 S Legend Color Black White White White White Black Black Black 10 MOUNTING/BARRIERS BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A 6-32 B ISO M3 FRONT CONNECTED (BACK MOUNTED ONLY)11 Back Mounting Foot Type Front Mounting Inserts (Optional Use) CShort 6-32 D Short ISO M3 ELong 6-32 F Long ISO M3 11 MAXIMUM APPLICATION RATING 1 120 VAC B 125 VDC, 120 A C13 120/240 VAC, 100 A D 240 VAC, 100 A 12 AGENCY APPROVAL UL 489 Listed & CSA Certified C UL 489 Listed, CSA Certified, & VDE Certified F Notes: 1 Standard multi-pole units identical poles except when specifying auxiliary switch (see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only. 2 Series Trip construction available w/either front or back connected terminals. 3 Series Trip construction with a voltage coil is not available as a single pole unit and must be tied to a protected pole. 4 On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only. 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. 6 Frequency & Delay Codes 92, 94 & 96 are not VDE Certified. 7 Current Ratings under 0.100 amps are not VDE Certified . 8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud (Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement. 9 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. 10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mouning inserts normally supplied. However, terminal connections must be made prior to mounting. 12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles. 13 Not available with VDE Certification. 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com E-Series Handle – Circuit & Terminal Diagrams | 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long. 4 51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long. 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com 8 | E-Series Handle (Back Connected) – Form & Fit Drawings Notes: 1 1/4 -20 stud terminal in Series Trip circuit configuration shown. 2 A 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 5 Circuit breakers must be mounted on vertical surface. 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com E-Series Handle (Front Connected) – Form & Fit Drawings | 9 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. 4 Circuit breakers must be mounted on vertical surface. REV_CB_E_01_2014 60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com