PC-Series Ground Fault Circuit Protection PC-Series General Specifications Overload, short circuit, & ground fault protection in a user friendly package!n a The PC-Series is suitable for: • • • The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. The PC-series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. Agency Certifications UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 1077 Supplementary Protectors UL Standard 943 Class A Ground Fault Circuit Interruptors UL Standard 1053 Ground Fault Sensing and Relaying Equipment UL Standard 1500 (pending) Ignition Protection Product Bulletin #135 May 2010 For Additional Information: Phone: Fax: email: web: mail: 1 (860) 793-9281 (860) 793-9231 [email protected] www.carlingtech.com Carling Technolgies Inc. 60 Johnson Ave Plainville, CT 06062 AC branch ground fault protection - a single circuit solution AC main ground fault protection for a boat’s entire AC electrical system Portable generator ground fault protection Key Benefits of the PC-Series: • • • • • Increases safety around boats and marinas Protects against electrical shock hazards in areas near water Protects against defects in the wires & conductors Reduces fire and shock hazards from defects in permanently installed appliances such as water heaters, battery chargers, lighting fixtures, etc. Detects low level ground faults, which do not trip ordinary circuit breakers, that can lead to fires and shock hazards for boating occupants Innovative Features: These precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not normally required, and heat-induced nuisance tripping is avoided. • Overload, short circuit and ground fault protection in a single package • Handle style actuators and rocker style “acuguard” • Wiping Contacts - Mechanical linkage with two-step actuation – cleans contacts, provides high, positive contact pressure & longer contact life • A trip-free mechanism, a safety feature, makes it impossible to manually hold the contacts closed during overload or fault conditions. • A common trip linkage between all poles, another safety feature, ensures that an overload in one pole will trip all adjacent poles. • Front panel mounting • Integral push-to-test button • Two integrated LED indicators distinguish if a breaker is closed with Line Voltage present, or has opened due to leakage current, or has opened due to over current, or is closed with no Line Voltage present. • Optional Hot/Neutral reversal detection and protection www.carlingtech.com PC-Series General Specifications Current Rating Electrical 1 - 50 Amps maximum Physical Voltage Rating 120VAC, 120/240VAC Leakage Current Trip Level 30mA & 6mA Leakage Current Trip Time For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds The above complies with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms The above complies with UL-943. Operating Frequency 50/60 Hz for 30mA leakage trip 60 Hz for 6mA leakage trip Interrupt Capacity 5,000 Amps Number of Poles (Breakers only) 1-pole (1 Circuit Breaker + 1 GFCISensor Module), 120V 2-pole (2 Circuit Breakers + 1 GFCI Sensor Module), 120/240V or 120V with Neutral Break. 3-pole 120/240V with Neutral Break (Sensor module has 2 pole width) Termination Circuit Breaker Line Side: #10-32, threaded stud. GFCI Sensor Module Load Side: #10-32 threaded stud. Neutral pigtail. Mounting Front Panel, #6-32 and M3 threaded inserts. Actuator Handle, Flat Rocker, Curved Rocker (with or without rocker guard), Push-to-Reset Rocker. 1000 Environmental Impedence 100 Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202G as follows: 10 O H M S 1 0.1 Shock Withstands 100 G, 6ms, sawtooth at rated current per Method 213, Test Condition "I". Vibration Withstands 0.06" excursion from 1055 Hz, and 10 G 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance/ Humidity 93% RH at 30°C for 168 Hours. Corrosion UL-943-6.21, 3 weeks Humidity: 30±2°C, 70±2% relative humidity Mixed Flowing Gases: 100 ppb H2S 20 ppb CI2 200±50 ppb NO2 Operating Temperature Mechanical -35°C to +66°C Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trips on short circuit, overload or leakage to ground, even when actuator is forcibly held in the “On” position 0.01 20.1 - 50.0 Innovative Features Indicator 0.001 0.01 AMPERE RATING 0.1 1 10 100 Two integrated LEDs, Red & Green •Green LED On, Red LED Off Line Voltage is present, the breaker is closed, and the device is protecting the circuits against over current and leakage current. •Green LED Off, Red LED On The device has detected leakage current and has opened the cicuit breaker. •Green LED Flashing, Red LED Off The circuit breaker has opened due to over current or has been turned off manually •Green LED Off, Red LED Off Line Voltage is not present •Green LED Flashing, Red LED Off, Amber LED ON Indicates Hot & Neutral are reversed and the circuit breaker is open Grounded Neutral Protection When neutral is grounded on load side of circuit Test Button Located on Ground Fault Module www.carlingtech.com Trip Free 2 PC-Series – Ordering Scheme PC B – B A – 24 – 620 – 1 B A – A 10 1 Series 1 SERIES PC 2 System Voltage/Poles 3 Circuit 4 Actuator 5 Frequency & Delay 2 SYSTEM VOLTAGE / POLES A 120 VAC single phase, one pole B 120/240 VAC single phase, two pole C 120/240 VAC single phase with switched neutral, three pole D 120 VAC single phase with switched neutral, two pole E 120 VAC single phase with reversed polarity indicator, two pole F 120/240 VAC single phase with reversed polarity indicator, three pole 3 CIRCUIT B Series Trip (Current) 4 ACTUATOR Handle A one per pole B one per multipole unit Two Color Curved Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single Color Curved Rocker J Vertical legend K Horizontal legend Two Color Curved Visi-Rocker Push-to-Reset N Vertical legend O Horizontal legend Single Color Curved Rocker Push-to-Reset R Vertical legend U Horizontal legend Two Color Flat Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single Color Flat Rocker 3 Vertical legend 4 Horizontal legend Two Color Flat Visi-Rocker Push-to-Reset 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Single Color Flat Rocker Push-to-Reset 7 Vertical legend 8 Horizontal legend 5 FREQUENCY & DELAY 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long Notes: 1 This device meets the requirements of ABCY E11. 2 6mA per UL943, available with agency approval code 10. 3 30mA per UL1053, available with agency approval codes 11 & 12. 4 AIC Rating at 120 VAC 3kA, at 120/240 VAC 5kA 3 6 Current Rating 7 Terminal 8 Actuator Color 6 CURRENT RATING (AMPERES) 285 0.850 210 0.100 290 0.900 215 0.150 295 0.950 220 0.200 410 1.000 225 0.250 512 1.250 230 0.300 415 1.500 235 0.350 517 1.750 240 0.400 420 2.000 245 0.450 522 2.250 250 0.500 425 2.500 255 0.550 527 2.750 260 0.600 430 3.000 265 0.650 435 3.500 270 0.700 440 4.000 275 0.750 445 4.500 280 0.800 7 TERMINAL 1 Stud, 10-32 threaded 8 ACTUATOR COLOR & LEGEND I-O ON-OFF Dual White A B 1 Black C D 2 Red F G 3 Green H J 4 Blue K L 5 Yellow M N 6 Gray P Q 7 Orange R S 8 9 Mounting/ Barriers 450 455 460 465 470 475 480 485 490 495 610 710 611 711 612 10 Trip Level 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 712 613 614 615 616 617 618 620 622 624 625 630 635 640 650 11 Agency Approval 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 Legend Color Black White White White White Black Black Black 9 MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Handle or Standard Rocker Bezel Threaded Insert, 2 per pole A 6-32 X 0.195 inches yes B ISO M3 x 5mm yes Rockerguard Bezel Threaded Insert, 2 per pole C 6-32 X 0.195 inches yes D ISO M3 x 5mm yes Standard Bezel with Recessed Off-Side Flat Rocker Threaded Insert, 2 per pole E 6-32 X 0.195 inches yes F ISO M3 x 5mm yes Push-to-Reset Bezel Threaded Insert, 2 per pole G 6-32 X 0.195 inches yes H ISO M3 x 5mm yes 10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT A 6 mA (Class A GFCI)2 E 30 mA (ELCB)1,3 11 AGENCY APPROVAL AA W/O Approvals 10 UL 9432 11 UL 10531,3 12 UL 1053 & UL 15001,3,4 www.carlingtech.com PC-Series Wiring Diagrams INDICATE OFF / SINGLE COLOR ROCKER ACTUATOR HANDLE / INDICATE ON ROCKER ACTUATOR TERMINAL LOCATIONS PCA 120 VAC VERSION PCB 120/240 VAC VERSION 3.015 [76.58] MAX. PCC 120/240 VAC VERSION W/ NEUTRAL BREAK 3.775 [95.88] MAX. PCD 120 VAC VERSION W/NEUTRAL BREAK www.carlingtech.com 4 PC-Series Wiring Diagrams & Panel Cut Out DRAWING FILE NO. CLA-8112 INDICATE OFF / SINGLE COLOR ROCKER ACTUATOR TERMINAL LOCATIONS HANDLE / INDICATE ON ROCKER ACTUATOR REVISIO REV DESCRIPTION X X PCE 120 VAC VERSION W/ REVERSE POLARITY PROTECTION & INDICATOR PCF 120/240 VAC VERSION W/ REVERSE POLARITY PROTECTION & INDICATOR NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRUCIT CODES A,B,E & F) 3.790 [96.27] 3.040 [77.22] 2.280 [57.91] 3.040 [77.22] 2.280 [57.91] .156 DIA. [Ø3.96] 2 PLC'S. TYP. PER POLE 1.660 [42.16] 1.453 [36.91] 1.260 [32.00] 2.062 [52.37] .200 [5.08] .432 [10.97] .750 [19.05] TYP. PCA, PCB PCD & PCE PCC & PCF PCA PCB, PCD & PCE PCC & PCF HANDLE ACTUATOR ROCKER ACTUATOR PANEL CUTOUT DETAIL TOLERANCES ±.005 [.12] 5 www.carlingtech.com PC-Series Dimensions 2.265 [57.53] MAX. 1.510 [38.35] 2.975 [75.57] 0.430 [10.92] 0.275 [6.99] 0.750 TYP. [19.05] 2.518 [63.96] 2.062 [52.37] 3.800 [96.52] 1.453 [36.91] 0.429 [10.91] 0.350 [8.89] NEUTRAL PIGTAIL (CIRCUIT CODE A+B ONLY) #6/32 / M3 MOUNTING INSERTS 0.125 [3.18] 1.245 1.660 [31.62] [42.16] 0.208 [5.28] 0.100 [2.54] NOTE: For additional circuit breaker dimensions, reference the C-Series Breakers in the Carling Circuit Protection catalog www.carlingtech.com 6 PC-Series – Time Delay Curves Time Delay Curves Instantaneous Medium Ultra Short Long Short NOTES: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. 7 www.carlingtech.com