CX-Series Circuit Breaker UL 489 Listed & Ideal for 380VDC Applications The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction. Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance even in the most demanding applications. Resources: Download 3D CAD Files IGS STP Watch Product Video Additional Features: UL 489 & UL 489B Listed TUV Certified IEC/EN 60947-2 Temperature stable hydraulic/magnetic overcurrent sensing technology. Optional relay trip circuit permitting remote operator system shut down. Applications: Perfect fit for 380VDC Applications. UL 489 Listed and ideal for integration into Information Technologies’ power distribution equipment utilizing high DC voltage input. The CX-Series is UL 489B Listed and ideal for integration into the combiner box or main disconnect of photovoltaic renewable energy systems. Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | CX-Series Circuit Breaker - General Specifications CX-Series Circuit Breaker DESIGN FEATURES HYDRAULIC/MAGNETIC SENSING COIL UPPER ARC RUNNER Aids in motivating arc off of movable contact and into arc chamber PATENT PENDING MAGNETIC FLUX BOOSTING TERMINAL CONFIGURATION Design enhances motivation of arc into arc chamber LOWER ARC RUNNER Aids in motivating arc off of stationary contact and into arc chamber MAGNETS ARC SPLITTER RETAINER w/ integrated pressurizing walls LARGE ARC GAP To generate high arc voltages (12) ARC DEIONIZING SPLITTER PLATES Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com CX-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS CIRCUIT CONFIGURATION VOLTAGE MAX CURRENT INTERRUPTING NUMBER RATING AMPS CAPACITY (AMPS) OF POLES MAX. RATING FREQUENCY SERIES 250 D.C. 15 5,000 1 250 / 500 D.C. 15 10,000 2 410 / 205 D.C. 50 10,000 2 Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR VOLTAGE CIRCUIT CONFIGURATION MAX. RATING SERIES SWITCH ONLY1 MAX INTERRUPTING CURRENT CAPACITY RATING AMPS (AMPS) FREQUENCY NUMBER APPLICATION OF POLES CODE 300 D.C. 1 - 75 5,000 1 TC1, OL0, U3 300 D.C. 76 - 125 3,000 1 TC1, OL0, U3 440 D.C. 1 -30 10,000 2 TC1, OL0, U3 440 D.C. 31 - 63 5,000 2 TC1, OL0, U3 600 D.C. 1 - 75 5,000 2 TC1, OL0, U3 600 D.C. 76 - 115 3,000 2 TC1, OL0, U3 600 D.C. 1 - 115 ---- 2 or 3 --- Notes: 1 Requires inclusion of a relay trip voltage coil Table C: Lists UL Listed (UL489B) configuration and performance capabilities as a Molded Case Switch CX SERIES TABLE C : UL489B LISTED PHOTOVATIC MOLDED CASE SWITCH VOLTAGE CIRCUIT CURRENT RATING INTERRUPTING CONFIGURATION MAX RATING FREQUENCY POLES (AMPS) RATING (AMPS) CONSTRUCTION NOTES 600 DC 21 50 - 100 600 May have a third pole that is a voltage trip pole 600 DC 42 110 - 175 600 May have a fifth pole that is a voltage trip pole SERIES Notes: 1 Two poles in series. 2 Two poles in series in parallel with 2 poles in series. Table D: TUV Certified Configuration to IEC / EN 60947-2. Low Voltage Switchgear and Controlgear - Circuit Breakers CX-SERIES TABLE D : TUV IEC/EN 60947-2 LOW VOLTAGE SWITCH GEAR & CONTROL GEAR / CIRCUIT BREAKER CIRCUIT CONFIGURATION SERIES VOLTAGE MAX. RATING FREQUENCY POLES 440 DC 2 CURRENT RATING (AMPS) 1-63 INTERRUPTING CAPACITY ICS / ICU (AMPS) 4,000 *Manufacturer reserves the right to change product specification without prior notice. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 4 | CX-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage Overload 600 VDC 50 operations at 600% of rated current for UL489, and at 150% of rated current for UL1077. RESISTANCEIMPEDANCE PER POLE VALUES RESISTANCE, VALUES fromfrom LineLine to Load Terminals to Load Terminals (ValuesBased Based on on Series Trip (Values Trip Circuit CircuitBreaker) Breaker) 1000 100 10 O H M S Current (amps) 0.1 -5.0 Tolerance (%) 15% 5.1-20.0 25% 20.1-125 35% Environmental 1 0.1 0.01 0.001 0.01 Endurance Max 10,000 ON-OFF operations @ 6 per minute; 6000 with rated current & voltage, and 4,000 cycles mechanical. Trip Free Trips on overload even when actuator is forcibly held in the “On” position. Trip Indication The operating handle moves positively to the “Off” position when an overload causes the breaker to trip. 0.1 1 10 AMPERE RATING 100-125 100 Physical Number of Poles Termination Termination Barrier Mounting Actuator Internal Circuit Config. Materials Weight Standard Color 1- 2 poles, + Auxiliary Switch Pole. 10-32 or M5 Screw Terminals 1/4-20 or M6 Threaded Stud Terminals Standard with multi-pole constructions Threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole) Handle, 1 per pole. Series Trip Housing - Glass filled Polyester Handle - Glass filled Polyester Line/Load Terminals - Copper Alloy. ~150 Grams (~5.3 Ounces). ~150 Grams (~5.3 Ounces). Housing - Gray. Handle - White, Black, Red, Green, Blue, Yellow, Gray, Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Withstands 100 Gs, 6ms saw tooth while carrying rated current per MILPRF-55629 and MIL-STD- 202G, Method 213G, Test Condition “I”. Instantaneous and ultra short curves tested at 90% of rated current Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, at rated current per MIL-PRF-55629 and MILSTD-202G, Method 240D, Test Cond. A. Instantaneous & ultrashort curves tested at 90% of rated current. MIL-PRF-55629 and MIL-STD- 202G, Method 106G, i.e., Ten 24- hour cycles at +25°C to +65°C, 80- 98% RH. Method 101, Condition A (90-95% RH at 5% NaCl Solution, 96 hrs). MIL-PRF-55629 and MIL-STD- 202G, Method 107G, Condition A (5-cycles at -55°C to +25°C to +85°C to +25°C). -40°C to +85°C. *Manufacturer reserves the right to change product specification without prior notice. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com CX-Series Circuit Breaker UL489 – Ordering Scheme | 5 C X 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR X Handle, one per pole 3 POLES 1 One 2 Two 5 AUXILIARY/ALARM SWITCH 0 w/o Aux Switch 10 Mounting Inserts 295 410 512 415 517 420 522 425 527 430 435 440 445 450 455 0.95 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.50 4.00 4.50 5.00 5.50 5 6 B 460 465 470 475 480 485 490 495 610 710 611 711 612 712 613 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 10.50 11.00 11.50 12.00 12.50 13.00 614 14.00 615 15.00 616 16.00 61717.00 61818.00 62020.00 62222.00 62424.00 62525.00 63030.00 63535.00 64040.00 64545.00 65050.00 12 G 11 Rating 12 Agency Approval Screw Terminal, M5 Stud, M6 Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black M3 Thread 11 MAX. APPLICATION RATING 12 250 VDC 13 250/500 VDC 1 15 205/410 VDC 7 CURRENT RATING (AMPERES) 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 9 Actuator Color & Legend 10 MOUNTING INSERTS A 6-32 Thread 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long AMPERES 2 2 A 8 Terminal 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 4 CIRCUIT B Series Trip (current) CODE 7 Current Rating 8 TERMINAL 2 Screw Terminal, 10-32 3 Stud, 1/4-20 1 SERIES C 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 620 12 AGENCY APPROVAL A Without Approvals G UL 489 Listed 1 UL 489 Listed, TUV to IEC60947-2 S Notes: 1 Only Available with 250/500 VDC up to 15 amps. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 6 | CX-Series Switch UL489B – Ordering Scheme C X 2 1 Series 2 Actuator S 0 4 Circuit 3 Poles 1 SERIES C 4 5 Four Five 4 CIRCUIT S Switch Only 5 RELAY TRIP VOLTAGE COIL RATING1,2 0 w/o Relay Trip Voltage Coil A 12 VDC B 24 VDC C 32 VDC D 48 VDC 6 FREQUENCY & DELAY 03 DC Switch Only 7 CURRENT RATING (AMPERES) 1,3 2-Pole Section 810 50A - 100A 4-Pole Section 917 110A - 175A 03 6 Frequency & Delay 810 7 Current Rating 3 2 A 8 Terminal 9 Actuator Color & Legend 06 14 10 Mounting Inserts 11 Rating 12 Agency Approval 8 TERMINAL4,5 3 Stud, 1/4-20 6 Stud, M6 A Stud, 1/4-20, w/ 10-32 Screw Terminals on Voltage Pole B Stud, M6, w/ M5 Screw Terminals on Voltage Pole 2 ACTUATOR X Handle, one per pole 3 POLES1,2 2 Two 3 Three 5 Relay Trip 9 HANDLE COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 10 MOUNTING INSERTS A 6-32 Thread B Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black M3 Thread 11 MAX. APPLICATION RATING 06 600VDC 12 AGENCY APPROVAL A Without approvals 14 UL489B Listed Notes: 1 2 Pole Unit is required for ratings between 50A - 100A. 4 Pole Unit is required for ratings between 110A - 175A. 2 A Relay Trip Voltage Coil Pole may be added to either the 2 or 4 Pole construction. The addition of this extra pole dictates a change in the designation for the number of poles in selection 3. 3 For Current Ratings between 50A - 100A select current code 810 (100A). For Current Ratings between 101A - 175A select current code 917 (175A). 4 Voltage Pole must have screw terminals. Switch Pole must have stud terminals. 5 On 3 Pole Unit, Voltage Pole to be located at P1 as standard. On 5 Pole Unit, Voltage Pole to be located at P3 as standard. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com CX-Series Circuit Breaker UL1077 – Ordering Scheme | 7 C X 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR X Handle, one per pole 4 CIRCUIT A 1 Switch Only (no coil) B Series Trip (current) 1 G Relay Trip (voltage) 76 CURRENT RATING (AMPERES) 420 522 425 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 10 Mounting Inserts 10 C 11 Rating 12 Agency Approval Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black 11 MAX. APPLICATION RATING 10 300VDC 114 440 VDC w/o factory installed terminal bus 144 440VDC with factory installed terminal bus 065 600VDC 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 9 Actuator Color & Legend 10 MOUNTING INSERTS A 6-32 Thread w/o terminal bus B M3 Thread w/o terminal bus 5 AUXILIARY SWITCH 0 w/o Aux Switch3 AMPERES 6 2 B 8 Terminal 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 3 POLES 1 One 2 Two 3 Three 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 7 Current Rating 8 TERMINAL 2 Screw Terminal, 10-32 3 Stud, 1/4-20 5 Screw Terminal, M5 6 Stud, M6 1 SERIES C CODE 660 2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 635 640 650 660 665 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 60.000 65.000 670 675 680 685 690 695 810 911 912 70.000 75.000 80.000 85.000 90.000 95.000 100.000 115.000 125.000 12 AGENCY APPROVAL A Without approvals C UL 1077 Recognized W UL 1077 Recognized & TUV Certified IEC/ EN 60947-29 Notes: 1 Only available when tied to a protected pole Requires special P/N consult factory for details 2 Voltage trip circuit coil not rated for continuous duty - use instantaneous delay code 10 3 Contacts Rated for 20A @ 80 VDC 4 440VDC Rating available in two different wiring configurations, see next page for more details 5 600 VDC only available with factory installed terminal bus (see next page for more details) 6 Single pole units available up to 125A, multi pole units limited to 115A Max. (see next page for more details) 7 3 Pole units must include one Auxiliary switch pole (circuit code A or G) - Requires Special Part Number. (see next page for more details) 8 Screw Terminals are limited to 50A max. 9 Agency approval code W only available with 440 VDC rating & circuit code B. Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 8 | CX-Series Circuit Breaker UL489 – Form & Fit Drawings 0.265 [6.73] 0.380 [9.65] 0.380 [9.65] 1.052 [26.72] 0.755 [19.18] MAXIMUM 0.579 [14.72] 0.265 [6.73] 0.755 [19.18] MAXIMUM 0.579 [14.72] 1.719 [43.66] +0.050 3.094 –0.020 78.59 +1.27 –0.50 2.062+0.020 [52.37+0.50] +0.050 3.094 –0.020 78.59 +1.27 –0.50 2.062+0.020 [52.37+0.50] 1.052 [26.72] 0.380 [9.65] 2.259+0.020 [57.38+0.50] 0.502 [12.75] 2.259+0.020 [57.38+0.50] 0.502 [12.75] 1.719 [43.66] 30.0º 0.755 [19.18] MAXIMUM 0.124 [3.16] 30.0º 0.124 [3.16] 0.265 [6.73] 0.626+0.020 [15.90+0.50] 2.264+0.020 [57.51+0.50] 1.719 [43.66] 1.017 [25.82] 1.515 [38.48] MAXIMUM 0.502 [12.75] 1.843+0.020 [46.81+0.50] 0.579 [14.72] 2.264+0.020 +0.050 [57.51+0.50] 3.094 –0.020 1.017 [25.82] 78.59 +1.27 –0.50 2.062+0.020 [52.37+0.50] 30.0º 1.052 [26.72] 1.843+0.020 [46.81+0.50] 2.259+0.020 [57.38+0.50] 0.626+0.020 [15.90+0.50] 0.124 [3.16] 3.672 [93.268] SHOWN WITH STUD TERMINAL CONFIGURATION 1.843+0.020 [46.81+0.50] SHOWN WITH STUD TERMINAL CONFIGURATION 2.264+0.020 [57.51+0.50] 0.626+0.020 [15.90+0.50] 2.259 [57.38] 1.515 [38.48] MAXIMUM 3.672 [93.268] 2.259 [57.38] & (205/410 VDC) 1.515 [38.48] MAXIMUM & (205/410 VDC) 0.744 [18.90] 0.744 &[18.90] (205/410 VDC) SHOWN WITH STUD TERMINAL CONFIGURATION 1.017 [25.82] 3.672 [93.268] 2.259 [57.38] 2.736 SHOWN WITH SCREW [69.49] TERMINAL CONFIGURATION (WITH SCREW TERMINAL) 2.946 1.520 [74.83] 2.736 SHOWN WITH SCREW [38.61] (WITH STUD TERMINAL) [69.49] TERMINAL CONFIGURATION 0.760 0.078 TYP 3.276 (WITH SCREW TERMINAL) [19.30] [1.98] [83.21] 2.946 1.520 (UNFOLDED BARRIER) [74.83] [38.61] (WITH STUD TERMINAL) 0.760 0.078 TYP 3.276 1.062 [19.30] [1.98] [83.21] [26.97] TOLERANCES +.005[.12] (UNFOLDED BARRIER) 2.7362.062 SHOWN WITH SCREW [52.37] [69.49] TERMINAL CONFIGURATION 0.744 1.062 [18.90] (WITH SCREW TERMINAL) 0.750 TYP [26.97] TOLERANCES +.005[.12]2.946 [19.05] 1.520 CX1 0.625 [74.83] 2.062[15.88] [38.61] CX2 (WITH STUD TERMINAL) [52.37] 0.760 3.276 [19.30] 0.750 TYP [83.21] [19.05] CX1 0.625 (UNFOLDED BARRIER) [15.88] CX2 1.062 [26.97] TOLERANCES +.005[.12] 0.078 TYP [1.98] 2.062 [52.37] 0.625 [15.88] CX1 CX2 Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 0.750 TYP [19.05] CX-Series Circuit Breaker UL489B – Form & Fit Drawings | 9 OPTIONAL VOLTAGE POLE SEE NOTE 1 POLE 1 CX3 POLE 2 CX2 POLE 3 CX3 - 2 POLE SWITCH (CX2)SHOWN WITH OPTIONAL VOLTAGE POLE 50A-100A DEVICE, 600VDC POLE 1 OPTIONAL VOLTAGE POLE SEE NOTE 2 POLE 2 SEE NOTE 3 POLE 3 POLE 4 POLE 5 CX5 - 4 POLE SWITCH (CX4)SHOWN WITH OPTIONAL VOLTAGE POLE 101A-175A DEVICE, 600VDC Notes: 1 3 pole configuration supplied with voltage coil on pole 1. Optional location pole 3. Consult factory. 2 5 pole configuration supplied with voltage coil in center pole. (Pole 3) 3 Line & Load connections requires bus connection as shown. Minimum cross selection .127 in2 (81.94 mm2) Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 10 | CX-Series Circuit Breaker UL1077 – Form & Fit Drawings Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com CX-Series Circuit Breaker - Delay Curves | 11 Instantaneous - DC 10 Ultrashort - DC 11 Short - DC 12 Medium - DC 14 Long - DC 16 Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 12 | Reps & Contact Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest WA ND Alaska, Hawaii « Sierra WY NE Omega Limited NV UT CA KS CO AZ NM AR Sunbelt Components Mexico LD. Allen NH Norris NY MA CT RI PA Pacent NJ DE MD WV TSI North TSI VA NC SC Pinnacle Marketing MS AL GA SOUTHEAST LA ProRep Solutions LATIN AMERICA Americas DM Assoc KY MO « « South America DM Mexico IL ME VT DM Assoc OH East OK TX Matrix IN TN Luscombe Engineering Signal Enterprises IA Dy-tronix Inc. Melody Emery MI ID Bridge Marketing WEST WI MN SD OR NORTHERN Hanna Lind Ltd. MT FL Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Notes | 13 Email: [email protected] • Application Support: [email protected] Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: [email protected] Northern Region Sales Office: [email protected] Southeast Region Sales Office: [email protected] Midwest Region Sales Office: [email protected] West Region Sales Office: [email protected] Latin America Sales Office: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China: [email protected] Shanghai, China: [email protected] Pune, India: [email protected] Kaohsiung, Taiwan: [email protected] Yokohama, Japan: [email protected] Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: [email protected] Germany: [email protected] France: [email protected] www.carlingtech.com REV_03_2015