Military Grade - Carling Technologies

Military Grade
COTS SWITCHES & CIRCUIT BREAKERS
About Carling Technologies:
Founded in 1920, Carling Technologies is a leading
manufacturer of electrical and electronic switches
and assemblies, hydraulic magnetic and thermal
circuit breakers, electronic controls, power distribution units, digital switching systems, and multiplexed
power distribution systems. With four ISO certified
manufacturing facilities and corporate offices
worldwide, Carling Technologies does much more
than manufacture electrical components, it engineers
powerful solutions! Our high standards of design
and manufacturing quality have afforded us the
ability to provide a full line of COTS (Commercial
Off-The-Shelf) switches and circuit breakers that
are guaranteed to withstand the rugged military
environment while keeping costs down.
Military COTS Switches
& Circuit Breakers:
Your Military equipment is only as tough as the
components used in building it! Carling Technologies
products feature a wide range of switches and circuit
breakers that were designed and tested to withstand
the rigorous military environment. Carling Technologies
COTS products provide military OEMs with a reliable and
cost effective solution to their design requirements. By
drawing upon over 90 years of design excellence, Carling
Technologies is also able to provide switch and circuit
breaker custom solutions that are sure to be compliant
with the most demanding environmental requirements.
Contents
Circuit Breakers
MS-Series ...........................................................................................................2
A-Series..............................................................................................................4
B-Series ..............................................................................................................6
C-Series..............................................................................................................8
E-Series ............................................................................................................10
F-Series ............................................................................................................12
Sealed Rocker Switches
V-Series Contura ..............................................................................................14
W-Series...........................................................................................................17
L-Series ............................................................................................................19
Miniature & Sub-Miniature Switches
1-Series Rocker ................................................................................................22
2-Series Toggle ................................................................................................23
3-Series Pushbutton.........................................................................................24
4-Series Slider ..................................................................................................25
Toggle Switches
F-Series Single Pole .........................................................................................26
G-Series Double Pole ......................................................................................27
DK/EK-Series Heavy Duty ................................................................................28
1
MS-Series Circuit Breaker
MS-Series Sealed Toggle
Circuit Breaker
All MS Series circuit breakers feature a durable metal
sealed toggle with a MIL-PRF-39019F ingress protection
level rating when mounted in panel, a robust actuator,
and sealed bushing. This class leading, low cost, COTS
circuit breaker was designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G
and is guaranteed to withstand the most rigorous military
environment.
1.375±.020
[34.93 ± 0.50]
.656
[16.66]
MAXIMUM
Ø.125 X .062[1.57]
[3.18]
MINIMUM DEPTH
Ø .391
[9.93]
.325
[8.26]
+2°
12° -4°
12° +2°
-4°
ON
OFF
.626 ± .020
[15.90 ± 0.50]
PANEL MOUNTING DETAIL
.373
[
3/8-32 HEX NUT
LOCKWASHER
+.007
-.041
+0.17
-1.04
9.47
]
ON-OFF INDICATOR PLATE
LOCKING RING
RUBBER "O" RING
1.634 ± .020
[41.50 ± 0.50]
Ø.170
[4.32]
.375
[9.53]
.375
[9.53]
#8 SCREW
TERMINAL
1.880 ± .031
[47.75 ± 0.78]
SOLDER LUG TERMINAL
.402
[10.21]
.138 ± .020
[3.51 ± 0.50]
1.099 ± .020
[27.91 ± 0.50]
LINE
2
LOAD
www.carlingtech.com
MS-Series Circuit Breaker
Electrical
Delay Curves
Current Rating ...................2 - 25 Amps
Voltage Rating ...................50 Volts DC
Dielectric Strength .............UL,CSA 1500V, 50/60 Hz for one
minute between all electrically
isolated terminals
Insultation Resistance ........Minimum of 100 Megohms @
500VDC
Dual Rated AC/DC
Instantaneous
Mechanical
Endurance..........................10,000 On-Off operations @ 6 per
minute with rated current and voltage
Trip Free.............................Trips on short circuit, overload, even
when actuator is forcibly held in the
“On” position
Trip Indication ....................The operating handle moves positively to the “Off” position when
an overload causes the circuit
breaker to trip
Short
Physical
Number of Poles................1 Pole
Weight ...............................Approximately 1.8 oz (50 G) per pole
Dimensions ........................See reverse side
Environmental
Designed in accordance with requirements of specification
MIL PRF-55629 & MIL-STD-202G as follows:
Shock .................................Withstands 100G’s, 6ms, saw tooth
while carrying rated current per
Method 213, Condition I. Instantaneous curves tested at 80% of
rated current.
Vibration ............................Withstands 0.060” excursion from
10-55 Hz, and 10G’s 55-500 Hz, at
rated current per Method 204C,
Test Condition A. Instantaneous
curves tested at 80% of rated current.
Salt Spray ...........................Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs)
Moisture Resistance...........Method 106G
Thermal Shock ...................Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C)
Operating Temperature .....-40°C to +85°C
Ingress Protection Level.....MIL-PRF-55629C when mounted
in panel.
Other .................................Materials used in this product shall
be non-nutrient to fungus growth
Medium
Resistance, Impedance Values
UL Approval Pending
www.carlingtech.com
3
A-Series Circuit Breaker
A-Series
Circuit Breaker
Compact in size and well known for its proven reliability, the
A-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application
environments. When aesthetics demand a clean contemporary and functional design, the visi-rocker two-color actuator
can be specified. A rockerguard and push-to-reset bezel
helps prevent inadvertent actuation. A specially constructed
version is now available for applications requiring CE markings. In addition, these breakers meet CSA Standard 22.2
No. 100 for the Generator & Welder markets. It can be configured as 1-6 poles (handle), 1-3 poles (rocker), 0.02 - 50
amps, up to 277 VAC or 80 VDC, with a choice of time delays, terminals and actuator colors.
Agency Certifications
UL Recognized
UL Standard 1077
Component Recognition Program as
Protectors Supplementary (Guide
CCN/QVNU2, File E75596)
UL Standard 508
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
UL Standard 1500
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
UL Listed
4
UL Standard 489A
Communications Equipment (Guide
CCN/DITT, File E189195)
CSA Accepted
Component Supplementary Protector
under Class 3215 30,
File 047848 0 000
CSA Standard C22.2 No. 235
TUV Certified
EN60934, under License No.
R72040875
VDE Certified
EN60934, VDE 0642 under File No.
10537
www.carlingtech.com
A-Series Circuit Breaker
Electrical
Mechanical
Maximum Voltage..............277VAC 50/60 Hz, 80VDC
Current Ratings ..................Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0, 50.0. Other ratings available consult ordering scheme.
Standard Voltage Coils ......DC-6V, 12V; AC-120V, Other ratings
available, consult ordering scheme.
Auxiliary Switch Rating.......SPDT; 10.1 A - 250VAC,
1.0 A - 65VDC/0.5 A - 80 VDC,
0.1A - 125VAC (with gold contacts).
Insulation Resistance .........Minimum: 100 Megohms at 500 VDC
Dielectric Strength .............UL, CSA - 1500V 60 Hz for one
minute between all electrically
isolated terminals. A-Series rocker
circuit breakers comply with the 8mm
spacing & 3750V dielectric requirements from hazardous voltage to
operator accessible surfaces per EN
60950 and VDE 0805.
Resistance, Impedance ......Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance..........................10,000 ON-OFF operations @ 6 per
minute; with rated Current & Voltage.
Trip Free.............................All A-Series Circuit Breakers will trip
on overload, even when the actuator
is forcibly held in the ON position.
Trip Indication ....................The operating actuator moves positively to the OFF position when an
overload causes the circuit breaker
to trip. When mid-trip handle is specified, the handle moves to the mid
position on electrical trip of the circuit
breaker. When mid-trip handle with
alarm switch is specified, the handle
moves to the mid position & the alarm
switch actuates when the circuit
breaker is electrically tripped.
Physical
Number of Poles................1 - 6 Poles (handle) and 1-3 poles
(rocker) at 30 Amps or less. 1 and 2
poles at 31 Amps thru 50 Amps.
Internal Circuit
Configurations ...................Series, (with or without auxiliary
switch), Shunt and Relay with current
or voltage trip coils, Dual Coil, Switch
Only with or without auxiliary switch.
Weight ...............................Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole)
Standard Colors .................Housing - Black; Actuator- See
Ordering Scheme.
Environmental
Pulse Tolerance Curves
www.carlingtech.com
Designed and tested in accordance with requirements of
specification MIL-PRF-55629 & MIL-STD-202 as follows:
Shock .................................Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Vibration ............................Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C, Test
Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Moisture Resistance...........Method 106D; ten 24-hour cycles @
+ 25°C to +65°C, 80-98% RH.56 days
@ +85°C, 85% RH.
Salt Spray ...........................Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock ...................Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature .....-40° C to +85° C
5
B-Series Circuit Breaker
B-Series
Circuit Breaker
Designed specifically for world market applications, the Bseries utilizes the hydraulic magnetic principle which provides precise operation and performance even when
exposed to extremely hot and/or cold application environments. Typical applications include power supplies, medical equipment, office equipment, control panels and
marine equipment. In addition, these breakers meet CSA
Standard 22.2 No. 100 for the Generator & Welder markets. It can be configured as 1-6 poles, 0.02 - 50 amps, up
to 277 VAC or 80 VDC, with choice of time delays, terminals and actuator colors.
Agency Certifications
UL Recognized
UL Standard 1077
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
UL Standard 508
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
UL Standard 1500
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
UL Listed
6
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E189195)
UL Standard 489A
Communications Equipment
(Guide CCN/DITT, File E189195)
CSA Accepted
Component Supplementary Protector
under Class 3215 30, FIle 047848 0 000
CSA Standard C22.2 No. 235
TUV Certified
EN60934, under License No.
R72040875
VDE Certified
EN60934, VDE 0642 under File
No. 10537
www.carlingtech.com
B-Series Circuit Breaker
Electrical
Mechanical
Maximum Voltage..............277VAC 50/60 Hz, 80VDC
Current Ratings ..................Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0, 50.0. Other ratings available consult ordering scheme.
Standard Voltage Coils ......DC-6V, 12V; AC-120V, Other ratings
available, consult ordering scheme.
Auxiliary Switch Rating.......SPDT; 10.1 A - 250VAC, 1.0 A65VDC/0.5 A - 80 VDC, 0.1A 125VAC (with gold contacts).
Insulation Resistance .........Minimum: 100 Megohms at 500 VDC
Dielectric Strength .............UL, CSA - 1500V 60 Hz for one
minute between all electrically
isolated terminals. A-Series rocker
circuit breakers comply with the 8mm
spacing & 3750V dielectric requirements from hazardous voltage to
operator accessible surfaces per
EN 60950 and VDE 0805.
Resistance, Impedance ......Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance..........................10,000 ON-OFF operations @ 6
per minute; with rated Current
and Voltage.
Trip Free.............................All B-Series Circuit Breakers will trip
on overload, even when Handle is
forcibly held in the ON position.
Trip Indication ....................The operating Handle moves positively to the OFF position when an
overload causes the breaker to trip.
Physical
Number of Poles................1 - 6 poles at 30 Amps or less. 1 and
2 poles at 31 Amps thru 50 Amps.
Internal Circuit Config. ......Series, (with or without auxiliary
switch), Shunt and Relay with current
or voltage trip coils, Dual Coil, Switch
Only (with or without auxiliary switch).
Weight ...............................Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole)
Standard Colors .................Housing- Black; Actuator - See
Ordering Scheme.
Environmental
Pulse Tolerance Curves
www.carlingtech.com
Designed and tested in accordance with requirements of
specification MIL-PRF- 55629 and MIL-STD-202 as follows:
Shock .................................Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition "I".
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Vibration ............................Withstands 0.060" excursion from 1055 Hz, and 10 Gs 55-500 Hz, at rated
current per Method 204C, Test Condition A. Instantaneous and ultrashort
curves tested at 90% of rated current.
Moisture Resistance...........Method 106D, i.e., ten 24-hour cycles
@ + 25°C to +65°C, 80-98% RH.
Salt Spray ...........................Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock ...................Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to
+25°C).
Operating Temperature .....-40° C to +85° C
7
C-Series Circuit Breaker
C-Series
The C-Series circuit breaker was designed for applications
that require higher amperage and voltage handling capabilities in a compact design. It is available with American
Standard or Metric Threaded Stud terminals, or Saddle
Clamp screw terminals. Additional options include mid-trip
handle style actuator, solid color rocker actuators and Visirocker two color actuators. The Visi-rocker option can be
specified to indicate either the ON or TRIPPED/OFF mode
while the optional Rockerguard and Push-To-Reset bezel
can help prevent inadvertent actuation.
The C-Series UL489 breakers employ a unique arc chute
design which results in obtaining higher interrupting
capacities, up to 50,000 amps. Thermoset glass filled
polyester half shell construction increases mechanical
& electrical strength and the Wiping Contacts - Mechanical
linkage with two-step actuation – cleans contacts, provides
high, positive contact pressure & longer contact life;
1-6 poles, 0.02 - 100 amps, up to 480 VAC or 80 VDC,
UL489 up to 240 VAC or 125 VDC, with choice of time
delays and actuator colors.
Agency Certifications
UL Recognized
UL Standard 1077
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
UL Standard 508
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
UL Standard 1500
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
CSA Certified
Circuit Breaker Model Case (Class
1432 01, File 093910),
CSA Standard C22.2 No. 5.1 - M
TUV Certified
EN60934, under License No.
R72040875
VDE Certified
EN60934, VDE 0642 under File No.
10537
UL Listed
8
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E189195)
UL Standard 489A
Communications Equipment
(Guide CCN/DITT, File E189195)
tCSA Accepted
Component Supplementary Protector
under Class 3215 30, FIle 047848 0
000 CSA Standard C22.2 No. 235
www.carlingtech.com
C-Series Circuit Breaker
Electrical
Mechanical
Maximum Voltage..............277VAC 50/60 Hz, 80VDC
Current Ratings ..................Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0, 50.0. Other ratings available consult ordering scheme.
Standard Voltage Coils ......DC-6V, 12V; AC-120V, Other ratings
available, consult ordering scheme.
Auxiliary Switch Rating.......SPDT; 10.1 A - 250VAC, 1.0 A65VDC/0.5 A - 80 VDC, 0.1A 125VAC (with gold contacts).
Insulation Resistance .........Minimum: 100 Megohms at 500 VDC
Dielectric Strength .............UL, CSA - 1500V 60 Hz for one
minute between all electrically isolated terminals. A-Series rocker circuit
breakers comply with the 8mm spacing & 3750V dielectric requirements
from hazardous voltage to operator
accessible surfaces per EN 60950
and VDE 0805.
Resistance, Impedance ......Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance..........................10,000 ON-OFF operations @ 6
per minute; with rated Current
and Voltage.
Trip Free.............................All B-Series Circuit Breakers will trip
on overload, even when Handle is
forcibly held in the ON position.
Trip Indication ....................The operating Handle moves positively to the OFF position when an
overload causes the breaker to trip.
Physical
Number of Poles................1 - 6 poles at 30 Amps or less. 1 and
2 poles at 31 Amps thru 50 Amps.
Internal Circuit Config. ......Series, (with or without auxiliary
switch), Shunt and Relay with current
or voltage trip coils, Dual Coil, Switch
Only (with or without auxiliary switch).
Weight ...............................Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole)
Standard Colors .................Housing- Black; Actuator - See
Ordering Scheme.
Environmental
Pulse Tolerance Curves
www.carlingtech.com
Designed and tested in accordance with requirements of
specification MIL-PRF- 55629 and MIL-STD-202 as follows:
Shock .................................Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition "I".
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Vibration ............................Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C,
Test Condition A. Instantaneous
and ultrashort curves tested at 90%
of rated current.
Moisture Resistance...........Method 106D, i.e., ten 24-hour cycles
@ + 25°C to +65°C, 80-98% RH.
Salt Spray ...........................Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock ...................Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature .....-40° C to +85° C
9
E-Series Circuit Breaker
E-Series
Circuit Breaker
Ideally suited for higher amperage applications, the E-Series
is available with front and back mounting, screw terminals,
stud terminals and heavy duty box wire connectors for solid
wire or a pressure plate connector for stranded wire. Consult
factory for an optional power selector device.
The E-Series is UL Listed and CSA Certified for Branch Circuit protection which does not require a fuse backup. It is
also UL Recognized and CSA Certified as a Supplementary
Protector and as a Manual Motor Controller.
1-6 poles, .1 - 100 amps, up to 600 VAC or 125 VDC, with
choice of time delays and actuator colors.
Agency Certifications
UL Recognized
UL Standard 1077
Component Recognition Program as
Protectors, Supplementary (Guide
QVNU2, File E75596)
UL Standard 508
Component Recognition Program as
Manual Motor Controls (Guide NLRV2,
File E135367)
Actual size
UL Standard 1500
Protectors, Supplementary for Marine
Electrical & Fuel Systems (Guide
PEQZ2, File E75596) Ignition Protection
Electrical
Table A:
Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations
& performance capabilities as a Molded Case Circuit Breaker.
UL Listed
10
UL Standard 489
Circuit Breakers, Molded Case (Guide
DIVQ, File E129899)
CSA Accepted
Component Supplementary Protector
(Class 3215 30, File 047848 0 000)
CSA Standard C22.2 No. 235
CSA Certified
Circuit Breaker Molded Case (Class
1432 01, File 093910), CSA Standard
C22.2 No. 5.1 - M
TUV Certified
EN60934 under License No.
R72031056
VDE Certified
EN60934, VDE 0642 under File No.
10537
www.carlingtech.com
E-Series Circuit Breaker
Electrical
Mechanical
Maximum Voltage..............600VAC 50/60 Hz, 125VDC
(See Table A)
Current Ratings ..................Standard current coils: 0.100, 0.250,
0.500, 1.00, 2.50, 5.00, 7.50, 10.0,
15.0, 20.0, 25.0, 30.0, 50.0, 60.0,
70.0 & 100 Amp.
Auxiliary Switch Rating.......SPDT; 10.1A 250VAC, 1.0A 65VDC;
0.5A 80VDC, 0.1A 125VAC (with
gold contacts).
Insulation Resistance .........Minimum of 100 Megohms at
500 VDC.
Dielectric Strength .............UL, CSA: 2200 V 50/60 Hz for one
minute between all electrically
isolated terminals. E-Series Circuit
Breakers comply with the 8mm
spacing and 3750V 50/60 Hz dielectric
requirements from hazardous voltage
to operator accessible surfaces,
between adjacent poles and from
main circuits to auxiliary circuits per
Publications EN 60950 and VDE 0805.
Resistance, Impedance ......Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance..........................10,000 ON-OFF operations @ 6
per minute; with rated Current
and Voltage.
Trip Free.............................All E-Series Circuit Breakers will trip
on overload, even when Handle is
forcibly held in the ON position.
Trip Indication ....................The operating Handle moves positively to the OFF position when an
overload causes the breaker to trip.
Physical
Number of Poles................1 - 6
Mounting ...........................A 3" minimum spacing must be
provided between the circuit breaker
arc venting area on back connected
E-Series circuit breakers and
grounded obstructions. E-Series
circuit breakers must be mounted
on a vertical surface.
Connectors, Box Type........Front connected E-Series circuit
breakers are supplied with box
type pressure connectors that accept
copper or aluminum conductors
as follows: 1/0-14 Copper,
1/0-12 Aluminum.
Internal Circuit ..................Series and Switch Only, (with or
Configuration
without auxiliary switch). Shunt with
current coils.
Weight ...............................Approximately 252 grams/pole
(Approximately 9 ounces/pole)
Standard Colors .................Housing-Black; Actuator - See
Ordering Scheme.
Environmental
Pulse Tolerance Curves
www.carlingtech.com
Designed and tested in accordance with requirements of
specification MIL-PRF- 55629 and MIL-STD-202 as follows:
Shock .................................Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Vibration ............................Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C,
Test Condition A.
Moisture Resistance...........Method 106D, i.e., ten 24-hour cycles
@ + 25°C to +65°C, 80-98% RH.
Salt Spray ...........................Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock ...................Method 107D, Condition A
(Five cycles @ -55°C to +25°C to
+85°C to +25°C).
Operating Temperature .....-40° C to +85° C
11
F-Series Circuit Breaker
F-Series
Circuit Breaker
F-Series breakers are available with current ratings up to
700 Amps. The optional 25 millivolt metering shunt construction provides a safe method for monitoring current
flowing through the breaker by simply connecting a meter
with light gauge wire to the appropriate terminals located
on the shunt housing at the rear of the breaker. This allows
applications to be customized by measuring and displaying
percentage of current, watts or safe/danger zones.
Agency Certifications
UL Listed
UL Standard 489A
Circuit Breakers, Molded Case, (Guide
DIVQ7, File E129899), UL Standard
489; Complies with the requirements
of CSA Standard for Molded Case
Circuit Breakers, CAN/CSA - C22.2
No. 5.1 - M
TUV Certified
EN60947-2
Low Voltage Switchgear and Control
Gear under License No. R72031058
Electrical
Table A:
Lists UL Listed (489)and CSA Certified (C22.2 N0. 5.1-M)
configurations and performance capabilities as a Molded
Case Circuit Breaker
Actual size
Table B:
Lists UL Listed configurations and performance capabilities
as Circuit Breakers for use in Communications Equipment
(Guide DITT, File E189195), under UL489A
12
www.carlingtech.com
F-Series Circuit Breaker
Electrical
Mechanical
Maximum Voltage..............125VDC
Current Ratings ..................Standard current coils: 100, 125, 150,
175, 225, 250 amps. 300, 350, 400,
500, 600, 700 amps available as
parallel pole construction.
Auxiliary Switch Rating.......SPDT; 10.1 Amps @ 250VAC, 1.0
Amps @ 65VDC, 0.5 Amps @ 80VDC
0.1 Amps @ 125VAC (with gold
contacts).
Insulation Resistance .........Minimum: 100 Megohms at 500 VDC
Dielectric Strength .............1960 VAC, 50/60 Hz for one minute
between all electrically isolated terminals, except 2500 VAC for one minute
between alarm/aux. switch and main
terminals with contacts in open and
closed position. F-Series circuit breakers comply with the 8mm spacing &
3750VAC 50/60 Hz dielectric requirements from hazardous voltage to
operator accessible surfaces, between
adjacent poles and from main circuits
to auxilary circuits per Publications EN
60950 and VDE 0805.
Resistance, Impedance ......Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance..........................4000 ON-OFF operations with rated
Current & Voltage & 4000 operations
with no load (8000 operations total)
@ 5 per minute. Parallel Pole construction: 1000 operations with rated
Current and Voltage @ 5 per minute.
Trip Free.............................All F-Series Circuit Breakers will trip
on overload, even when the actuator
is forcibly held in the ON position.
Trip Indication ....................The operating actuator moves positively to the OFF position when an
overload causes the circuit breaker
to trip.
Physical
Number of Poles................1 - 3 Poles Note: Ratings over
250 Amps only available with
parallel pole.
Internal Circuit Config. ......Series (with or without auxiliary
switch), Switch Only (with or without
auxiliary switch).
Available Accessories ........Factory installed: DC Current Metering Shunt (25 mV @lr)
Weight ...............................Varies depending on construction.
Consult factory.
Standard Colors .................Housing - Black; Actuator - Black
or White with contrasting
ON-OFF legend.
Environmental
Designed and tested in accordance with requirements of
specification MIL-PRF-55629 & MIL-STD-202 as follows:
Shock .................................Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Vibration ............................Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C, Test
Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Moisture Resistance...........Method 106D; ten 24-hour cycles @
+ 25°C to +65°C, 80-98% RH. 56
days @ +85°C, 85% RH.
Salt Spray ...........................Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock ...................Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to
+25°C).
Operating Temperature .....-40° C to +85° C
www.carlingtech.com
13
V-Series Contura Switches
V-Series
Contura Switches
V-Series switches offer countless unique options including
choices for ratings, colors, illuminations and symbols. These
switches feature removable actuators in a choice of actuator
styles and colors, and are available in single or double pole
configurations. The V-Series switches can be illuminated
with either square, oval and/or bar shaped lenses.
Typical Vehicles Applications: Amphibious, Special Task,
Armored, SWAT/Assault, Law Enforcement, Mobile Crime
Lab, Security and Medical Vehicles.
Contura II & III
The Contura II & III actuators are constructed of
thermoplastic polycarbonate and are offered with either a hard nylon overlay or a “soft-touch” elastomer
overlay. These Contura models incorporate aesthetic
designs on the top and bottom of the rocker featuring
two rows of raised “bumps” on the Contura II and
three “indented” lines on the Contura III.
Contura V
The symmetrically curved Contura V actuator provides
the perfect complement to the Contura IV’s “Shape
to create a Shape” design concept. With its flush
style mounting bracket, Contura V can be mounted
in between two Contura IV’s, by itself, or in groups.
Contura X & XI
The raised bracket/bezel on the Contura X & XI helps
prevent inadvertent actuation of the rocker, as well as
preventing debris from being trapped under the
actuator. Both The Contura X concave rocker and the
convex style Contura XI are available with a variety
of lenses and legends.
14
www.carlingtech.com
V-Series Contura Switches
MAXIMUM DESIGN OPTIONS WITH
MINIMUM INVENTORIES
Panel redesign is a snap, requiring no tooling change,
with our removable interchangeable actuators.
A unique balance between aesthetics and functionality.
SEALS OUT WATER, DUST AND DEBRIS
Dual seal protection locks out elements. Certified to
IP66/IP68 for front panel components.
CLEAN CONNECTIONS
Offered in both eight and ten terminal base options to
accommodate most any circuit need. AMP & Packard
compatible connectors available.
WITHSTANDS EXTREME TEMPERATURES
Roller pin mechanism eliminates need for lubricants,
so it can withstand from -40°C to +85°C.
MULTIPLE LIGHTING OPTIONS
Incandescent lamps & LED lighting. Our LED illumination
is offered in a wide array of light intensities, colors, as
well as dual level, tri-color, and flashing options.
OPTIONAL PANEL SEAL
Helps prevent water/dust ingress behind panel.
DIMENSIONAL SPECIFICATIONS: IN. [MM]
CONTURA II & III STYLE
CONTURA X & XI STYLE
SHOWN WITH RAISED
BRACKET AND TWO SQUARE
LENSES
1.910[48.51]
.426[10.82]
.350[8.89]
1.506[38.25]
1.370[34.79]
8 TERMINAL BASE
W/O BARRIERS
www.carlingtech.com
10 TERMINAL BASE
W/O BARRIERS
15
V-Series Contura Switches
Electrical
Agency Certifications
Contact Rating...................0.4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
10A, 14VT
6A, 125VAC L
Dielectric Strength .............1500 Volts RMS
Insulation Resistance .........50 Megaohms
Initial Contact Resistance...10 milliohms max. @ 4VDC
Life .....................................50,000- 100,000 cycles
circuit dependent
Contacts.............................Silver alloy, silver tin-oxide, fine silver
Terminals............................Brass or copper/silver plate 1/4”
(6.3mm) Quick Connect terminations
standard. Solder lug, Wire Lead
Mechanical
Endurance..........................150,000 cycles minimum
Physical
Lighted...............................Incandescent - rated 10,000 hours
Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24VDC)
Seals...................................Internal
Optional external gasket panel seal
Base ...................................Polyester blend rated to 125°C with a
UL flammability rating of 94V0.
Contura II, III, IV, V, VI
Actuator .............................Hard Surface: Basic actuator structure
molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic
surface overlay. Soft Surface: Basic
actuator structure molded of thermoplastic polycarbonate with an elastomer overlay.
Contura X, XI, XII
Actuator, VP .......................Nylon 66 Reinforced rated to 105°C
Lens ...................................Polycarbonate rated at 100°C
Actuator Travel (Angular Displacement)
2 position ...........................18°
3 positions .........................9° from center
Mounting Specifications
.830[21.08]
Panel Thickness Range
# of gaskets Acceptable Panel Thickness
0
030 to .250 (.76mm to 4.76mm)
1
030 to .109 & .147 to .157
1.450[36.83]
(.76 to 2.77mm & 3.73 to 3.98mm)
Recommended: No gasket with panel thickness
of .032, .062, .093, .125,.187 or .250
TEST CUT
HOLE IN
ACTUAL
MATERIAL
SWITCH
MOUNTING HOLE
16
Environmental
Environmental....................Sealed version: IP68, in accordance with
IEC 529, BS 5490, DIN 400 50 & NFC 20
010. This rating applies to front panel
components of the actual switch only,
and signifies protection against dust and
the prolonged effects of immersion
under pressure. The standard test for
immersion under pressure requires
submersion under one meter of water
for 30 minutes. The V-Series switch has
exceeded these parameters, having
been actuated and illuminated during
submersion.
Corrosion ...........................Flowing Mixed Gas (FMG)
Class III 3 year accelerated exposure
per ASTM B-827, B-845
Silver and gold contacts
Operating Temperature......-40°C to + 85°C
Vibration 1...........................Per Mil-Std 202F, Method 204D Test
Condition A 0.06 DA or 10G’s 10-500
Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and
pre and post test contact resistance.
Vibration 2...........................Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s max.
Random
24 Hz
0.06 PSD-Gsq/Hz
60 Hz
0.50
100 Hz
0.50
200 Hz
0.025
2000 Hz
0.025
No loss of circuit during test; <10µ
seconds chatter.
Shock...................................Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with VCH
connector. Test criteria - No loss of
circuit during test, pre and post test
contact resistance.
Salt Spray ............................Per Mil-Std 202F, Method 101D, Test
Condition A, 48 Hrs. Sealed version only.
Dust.....................................Per Mil-Std 810C, Method 510.2 Air
Velocity 300 ±200 Feet/Min, Test
Duration 16 Hrs.
Thermal Shock ....................Per Mil-Std 202F, Method 107F, Test
Cond. A, -55°C to 85°C. Test criteria pre and post test contact resistance
Moisture Resistance ............Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance
Ignition Protection ..............All Contura switches with sealed construction meet the requirements of
UL1500/ISO8846 for ignition protection,
in addition to conformance with EC
directive 94/25/EC for marine products.
www.carlingtech.com
W-Series Fully Sealed Rocker Switches
W-Series Fully Sealed
Rocker Switches
Carling Technologies set the standard for performance,
reliability and aesthetics with the widely successful, often
imitated, but never duplicated, V-Series rocker switches.
Building further upon that platform, Carling has once again
raised the bar with the fully sealed W-Series. The W-Series
traditional appearance features complete IP68 protection,
even below the panel, where the critical connection is
made from your wiring harness. When used in conjunction
with the integrated connector, the totally submersible
W-Series provides a seal for up to ten individual wires,
assuring compatibility with even the most complex circuitry.
The W-Series also offers a wide variety of accoutrements
including endless illumination options featuring dual level
and multicolor LEDs, progressive and hazard warning circuits, ratings up to 10A 24V, choice of paddle, rocker, locking or laser etched actuators, hundreds of standard legend
choices and the electrical performance and reliability that
is the hallmark of Carling Technologies products.
Typical Vehicles Applications: Amphibious, Special Task,
Armored, SWAT/Assault, Law Enforcement, Mobile Crime
Lab, Security and Medical Vehicles.
TRI-SEAL DESIGN
Affords IP68 protection for the entire
switch including teminals and connector.
CONNECTOR WITH
TWIN LOCKING TABS
Provides sealed water tight connections as
well as simple removal using only your hands.
PROVEN SWITCH MECHANISM
Butt-Action contacts are available in a
wide variety of circuitry and platings to
accommodate most any application.
AN EASY RETROFIT
W-Series fits industry standard
mounting hole 1.450 x .830.
www.carlingtech.com
FUNCTIONALITY UNDER
EXTREME CONDITIONS
Roller pin mechanism is lubricant free,
withstanding temperatures from
-40°C to +85°C.
17
W-Series Fully Sealed Rocker Switches
Electrical
Environmental
Contact Rating....................0.4VA @ 24VDC
10 amps, 3-24VDC
Dielectric Strength .............1500 Volts RMS
Insulation Resistance .........50 Megaohms
Initial Contact Resistance...10 milliohms max. @ 4 VDC
Life .....................................100,000 cycles
Contacts.............................Silver tin-oxide, 88/12
Terminals............................Copper with silver or gold plating.
Quick Connect terminations.
Voltage...............................3-24 VDC
Overcurrent........................15A for 50 cycles
Environmental....................IP68, Fully sealed
Corrosion/
Chemical Splash ................Flowing Mixed Gas (FMG)
Class III 3 year accelerated exposure
per ASTM B-827, B-845
Operating Temperature .....-40°C to +85°C, 22 cycles, 300 hours
Vibration 1 .........................Per Mil-Std 202F, Method 204D Test
Condition A 0.06 DA or 10G’s 10-500
Hz.
Vibration 2 .........................Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s max.
Random
24 Hz
0.06 PSD-Gsq/Hz
60 Hz
0.50
100 Hz
0.50
200 Hz
0.025
2000 Hz
0.025
Handling/Drop...................One meter onto concrete floor
Salt Spray ...........................Per Mil-Std 202F, Method 101D,
Test Condition A, 48 Hrs.
Dust ...................................IP6X
Thermal Shock ...................Per Mil-Std 202F, Method 107F,
Test Condition A, -55°C to 85°C.
Test criteria - pre and post test
contact resistance
Moisture Resistance/
Humidity ............................Per Mil-Std 202F, Method 106F,
Test Criteria - pre and post test
contact resistance
Mechanical
Endurance..........................250,000 cycles minimum
Physical
Lighted...............................LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for voltages to 24 VDC)
Seals...................................Neoprene
Base ...................................Polyester blend rated to 125C with a
UL flammability rating of 94V0.
Actuator .............................Basic actuator structure molded of
thermoplastic polycarbonate with a
hard Nylon 66 thermoplastic surface
overlay.
Lens ...................................Polycarbonate rated at 100°C
Function .............................2 & 3 Position Rocker Style
Operation ..........................Maintained & Momentary
Base ...................................PA 6/6 30GF (glass filled)
Actuator .............................PA 6/6 13GF
Bracket...............................PBT 10GF
Connector..........................PBT 10GF, polarized
Mounting Specifications
Panel Thickness Range .032 to .125
For optimum panel fit, the following
panel thicknesses are suggested:
.032, .062, .093, .125
Actuator Travel (Angular Displacement)
24° full throw
1.000
[25.40]
.830[21.08]
1.450[36.83]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
SWITCH
MOUNTING HOLE
1.724
[43.78]
12°
KEYING FEATURE
1.962
[49.83]
SWITCH SHOWN WITH
CONNECTOR INSTALLED
.418
[10.62]
1.707
[43.36]
2.162
[54.91]
1.178 [29.93]
.714
[18.14]
1.080
[27.43]
.465
[11.81]
.031
[.79]
.110
[2.79]
WCH CONNECTOR
(190-31214-001)
1.200
[30.48]
1.664
[42.27]
DIMENSIONAL SPECIFICATIONS: IN. [MM]
Notes:
WCH connector is intended for use with Tyco/Amp .110 Junior Power Timer, female contacts, and wire seals. For 1416 awg wire, specify Tyco/Amp P/N 927766-3. For 16-20 awg wire, specify Tyco/Amp P/N 927770-3. Tyco/Amp cable
seal P/N 828904-1 (20-18 awg wire) or P/N 828905-1 (16-14 awg wire) is revquired for each individual wire lead, and
Tyco/Amp cable plug, P/N 828922-1, is required to seal each unused connector opening. Consult Tyco/Amp for the
cable seal recommended for your specific wire gauge and thickness.
18
www.carlingtech.com
L-Series Sealed Switches
L-Series
Sealed Switches
Making the right connections has never been easier —
with the L-Series Rocker Switch from Carling Technologies. Not only does this innovative switch offer total design flexibility, it has set new standards for both
performance and reliability. It’s IP67 certified, and able to
withstand temperatures from -40°C to +85°C. A 12 terminal switch base accommodates countless switch and
lamp circuit combinations. Additional features include
LED illuminated lenses or laser etched rockers, as well as
hundreds of legend choices and several accessories.
Typical Vehicles Applications: Amphibious, Special Task,
Armored, SWAT/Assault, Law Enforcement, Mobile
Crime Lab, Security and Medical Vehicles.
ELIMINATES NEED FOR RETOOLING
Neatly proportioned, our L-Series fits an industry standard
mounting hole of 1.734” x .867” (44.0 mm x 22.0 mm).
INTEGRATES EASILY INTO YOUR SYSTEM
You can choose from a variety of termination options,
including .250 TAB QC & .187 TAB QC. Optional connector
allows for prewiring of wire harnesses.
ENSURES GREATER SHOCK PROTECTION
Welded lamp connection and one-piece internal, jumperless
terminal withstand extreme shock and vibration.
WITHSTANDS EXTREME TEMPERATURES
Roller pin mechanism eliminates need for lubricants,
so it can withstand from -40°C to +85°C.
MAXIMIZES YOUR DESIGN FLEXIBILITY
Twelve terminals offer you an extensive range of switch and
lamp circuit options, including LED or incandescent illumination.
www.carlingtech.com
19
L-Series Sealed Switches
Electrical
Environmental
Contact Rating...................0.4VA @ 24VDC (MAX) resistive, 15
amps, 125VAC, 10 amps, 250VAC, 20
amps, 4-14VDC, 15 amps, 15-28VDC
Dielectric Strength .............1250 Volts RMS between pole to
pole, 3750 Volts RMS between live
parts and accessible surfaces
Insulation Resistance .........50 Megaohms
Initial Contact Resistance...10 milliohms max. @ 4VDC
Life ....................................100,000 cycles maintained, 50,000
cycles momentary at rated voltage
and current
Contacts.............................90/10 silver-nickel, silver tin-oxide, gold
Terminals............................Brass or copper/silver plate 3/16”
(4.76mm) & 1/4” (6.3mm) Quick
Connect terminations standard.
Environmental....................IP67 for above panel components of
the actual switch, representing an
index of protection as applied to
electrical equipment in accordance
with IEC 529, BS 5490, DIN 400 50 &
NFC 20 010.
Corrosion Resistance .........Mixed Flowing Gas MFG Class III per
ASTM B-827 & B-845, Method H,
with 3 years exposure.
Operating Temperature .....-40°C to + 85°C
Vibration 1 .........................Per Mil-Std 202F, Method 204D Test
Condition A 0.06 DA or 10G’s 10-500
Hz. Tested with VCH connector.
Test criteria - No loss of circuit during
test and pre and post test contact
resistance.
Vibration 2 .........................Resonance search 24-50 Hz 0.40
DA50-2000 ±10 G’s peak. Results
Horizontal Axis 3-5 G’s max.
Random
24 Hz
0.06 PSD-Gsq/Hz
60 Hz
0.50
100 Hz
0.50
200 Hz
0.025
2000 Hz
0.025
No loss of circuit during test;
<10µ chatter.
Shock .................................Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with
VCH connector. Test criteria - No loss
of circuit during test, pre, and post
test contact resistance.
Salt Spray ..........................Per Mil-Std 202F, Method 101D, Test
Condition A, 48 Hrs.
Thermal Shock ...................Per Mil-Std 202F, Method 107F, Test
Condition A, -55°C to 85°C.
Test criteria - pre and post test contact resistance.
Moisture Resistance ..........Per Mil-Std 202F, Method 106F,
Test Criteria - pre and post test
contact resistance.
Mechanical
Endurance..........................250,000 cycles minimum
Physical
Lighted...............................Incandescent - rated 10,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for voltages to 24 VDC)
Seals...................................Rocker, base & bracket are sealed.
Base ...................................Nylon 66 GF rated to 85°C with a
flammability rating of 94V0.
Rocker ................................Nylon 66 Reinforced, rated to 105°C
(modular lens). Locking rocker, standard rocker & paddle. Laser etching
with a polycarbonate actuator.
Lock ...................................Acetal
Lens ...................................Polycarbonate rated at 100°C.
Bracket...............................Nylon Zytel
Connector..........................Nylon 66 rated at 85°C. Polarized.
Actuator Travel (Angular Displacement)
2 position ...........................26°
3 positions .........................13° from center
Mounting Specifications
.867 [22.02]
1.734 [44.04]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
Panel Thickness Range
Acceptable Panel Thickness
.030 to .156 (.76mm to 3.96mm)
Recommended:
.030, .062, .093, .125 and .156
MOUNTING HOLE
20
www.carlingtech.com
L-Series Sealed Switches
DIMENSIONAL SPECIFICATIONS: IN. [MM]
L-SERIES
L-SERIES
SHOWN WITH LASER ETCHED
ACTUATOR
SHOWN WITH ROCKER GUARD
1.970 [50.04]
1.020 [25.91]
.435 [10.16]
.400 [10.16]
1.450 [36.83]
.855 [21.72]
L-SERIES
L-SERIES
SHOWN WITH LARGE LENS
AND PADDLE ACTUATOR
SHOWN WITH BAR LENS, LOCK
AND CONNECTOR
1.970 [50.04]
1.020 [25.91]
.453 [11.51]
.400 [10.16]
LC1-01
LC2-01
LC3-01
L-SERIES
12 4 3
2 1 10
12 4 3
2 1 10
2.380 [60.45]
L-SERIES
CONNECTOR
HOLE PLUG
BLACK .250 TAB CONNECTOR (PACKARD 630 SERIES)
BLACK .187 TAB CONNECTOR (PACKARD 480 SERIES)
1.970 [50.04]
BLACK .250 TAB CONNECTOR (AMP ONLY)
LH1
LH2 HOLE PLUG WITH
REMOVABLE HOLE PLUG
WITH NON-SERRATED WINGS
SERRATED WINGS
1.020 [25.91]
.500 [12.70]
1.325 [33.66]
.920 [23.37]
1.710 [43.43]
www.carlingtech.com
.790 [20.07]
.300 [7.62]
.855 [21.72]
21
1-Series Miniature/Sub-Miniature Switches
1-Series Miniature/
Sub-Miniature Switches
Typical Equipment Applications: Communication,
GPS Tracking, Radar, Mobile Medical, and
Audio/Visual Equipment
22
Specifications
Materials
Electrical Life......................1S1-Series: 30,000 make &
break cycles @ full load
1SS & 1SM-Series: 50,000 make
& break cycles @ full load
1M1-Series: 50,000 make &
break cycles @ full load
1MS-Series: 30,000 make &
break cycles @ full load
Contact Resistance ............1S-Series: 20 mΩ max. initial @ 2-4
VDC 100mA for both silver & gold
plated contacts
1M-Series: 10 mΩ max. initial @ 2-4
VDC 100mA for both silver & gold
plated contacts
Insulation Resistance .........1000 MΩ min.
Dielectric Strength .............1500 Volts RMS @ sea level
Operating Temperature .....-30ºC to +85ºC
Index of Protection ............1SS & 1SM-Series: IP67
1MS-Series: IP67
Solder Heat Resistance......MIL-STD-202, Method 210
Actuator Travel...................25º
Case ...................................all UL 94V-0
1S1-Series: Dially phthalate (DAP)
1SS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
1SM-Series: Glass filled nylon 4/6,
flame retardant, heat stabilized
1M1-Series: Dially phthalate (DAP)
(UL 94V-0)
1MS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
(UL 94V-0)
Rocker ................................1S1-Series: Nylon (UL 94V-0)
1SS & 1SM-Series: Nylon, black
standard, internal o-ring sealed
Rocker/Paddle ...................1M1-Series: Nylon (UL 94V-0)
1MS-Series: Nylon, black standard,
internal o-ring sealed
Bushing ..............................1S1-Series: Brass, nickel plated
1SS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
(UL 94V-0)
1SM-Series: Glass filled nylon 4/6,
flame retardant, heat stabilized
1M1-Series: Brass, nickel plated
1MS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
(UL94V-0)
Housing .............................1S1-Series: Stainless Steel
1M1-Series: Stainless Steel
1MS-Series: Spring Steel
Bracket...............................1M1-Series: Stainless Steel
1MS-Series: Nylon (UL 94V-0)
Actuator Pivot Retainer......1MS-Series: Stainless Steel
Switch Support ..................Brass, tin plated
Terminal Seal .....................Epoxy
www.carlingtech.com
2-Series Miniature/Sub-Miniature Switches
2-Series Miniature/
Sub-Miniature Switches
Typical Equipment Applications: Communication,
GPS Tracking, Radar, Mobile Medical, and
Audio/Visual Equipment
Specifications
Materials
Electrical Life......................2S-Series: 30,000 make & break
cycles @ full load
2M-Series: 50,000 make & break
cycles @ full load
Contact Resistance ............2S-Series: 20 mΩ max. initial @ 2-4
VDC 100mA for both silver & gold
plated contacts
2M-Series: 10 mΩ max. initial @ 2-4
VDC 100mA for both silver & gold
plated contacts
Insulation Resistance .........1000MΩ min.
Dielectric Strength .............1500 Volts RMS @ sea level
Operating Temperature .....-30ºC to +85ºC
Index of Protection ............2SS & 2SM-Series: IP67
2MS-Series: IP67
Solder Heat Resistance......MIL-STD-202, Method 210
Actuator Travel...................25º
Case ...................................all UL 94V-0
2S1-Series: Dially phthalate (DAP)
2SS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
2SM-Series: Glass filled nylon
4/6,flame retardant, heat stabilized
2M1-Series: Dially phthalate (DAP)
2MS & 2M2-Series: Glass filled
nylon 6/6, flame retardant,
heat stabilized
Toggle................................2S1-Series: Brass, chrome plated
2SS & 1SM-Series: Brass, chrome
plated or nylon, internal o-ring sealed
2M1-Series: Brass, chrome plated
2MS & 2M2-Series: Brass, chrome
plated or nylon, internal o-ring sealed
Bushing ..............................2S1-Series: Brass, nickel plated
2SS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
(UL 94V-0)
2SM-Series: Glass filled nylon 4/6,
flame retardant, heat stabilized
(UL 94V-0)
2M1-Series: Brass, nickel plated
2MS & 2M2-Series: Glass filled
nylon 6/6, flame retardant,
heat stabilized (UL 94V-0)
Housing .............................Stainless Steel
Switch Support ..................Brass, tin plated
Terminal Seal .....................Epoxy
www.carlingtech.com
23
3-Series Miniature/Sub-Miniature Switches
3-Series Miniature/Sub-Miniature
Pushbutton Switches
Typical Equipment Applications: Communication,
GPS Tracking, Radar, Mobile Medical, and
Audio/Visual Equipment
24
Specifications
Materials
Electrical Life......................50,000 make & break cycles
@ full load
Contact Resistance ............3SM & 3SS Series: 20 mΩ max.
initial @ 2-4 VDC 100mA for both
silver & gold plated contacts
3MN & 3MA-Series: 10 mΩ max.
initial @ 2-4 VDC 100mA for both
silver & gold plated contacts
3MS-Series: 50 mΩ max. initial @ 2-4
VDC 100mA for both silver & gold
plated contacts
Insulation Resistance .........1000 MΩ min.
Dielectric Strength .............1500 Volts RMS @ sea level
Operating Temperature .....-30ºC to +85ºC
Index of Protection ............3SS & 3SM-Series: IP67
3MS-Series: IP68
Cap Installation Support ....3MS-Series: 10 lbs. max.
Solder Heat Resistance......MIL-STD-202, Method 210
Actuator Travel...................25º
Case ...................................UL 94V-0
3S1-Series: Dially phthalate (DAP)
3SS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
3SM-Series: Glass filled nylon 4/6,
flame retardant, heat stabilized
3MN & 3MA-Series: Dially phthalate
(DAP) (UL 94V-0)
3MS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
(UL 94V-0)
Plunger ..............................3S1-Series: Thermoplastic
polyester, black
3SS-Series: Thermoplastic
polyester (UL 94V-0), with internal
o-ring seal
3SM-Series: Glass filled nylon 4/6,
flame retardant, heat stabilized
3MN-Series: Thermoplastic
polyester, black
3MS & 3MA-Series: Glass filled
nylon or glass filled polyester
(UL 94V-0)
Bushing ..............................3S1-Series: Brass, nickel plated
3SS-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
(UL 94V-0)
3SM-Series: Glass filled nylon 6/6,
flame retardant, heat stabilized
(UL 94V-0)
3MN-Series: Brass, nickel plated
3MA-Series: Zinc, nickel plated
Housing .............................3SM & 3SS-Series: Stainless Steel
3MN & 3MA-Series: Stainless Steel
Switch Support ..................3SM & 3SS-Series: Brass, tin plated
3MS-Series: Stainless Steel
Terminal Seal .....................Epoxy
www.carlingtech.com
4-Series Miniature Switches
4-Series Sub-Miniature
& Miniature Slide Switches
Typical Equipment Applications: Communication,
GPS Tracking, Radar, Mobile Medical, and
Audio/Visual Equipment
Specifications
Materials
Electrical Life......................30,000 make & break cycles
@ full load
Contact Resistance ............10 mΩ max. initial @ 2-4 VDC
100mA for both silver & gold
plated contacts
Insulation Resistance .........1000 MΩ min.
Dielectric Strength .............1500 Volts RMS @ sea level
Operating Temperature .....-30ºC to +85ºC
Solder Heat Resistance......MIL-STD-202, Method 210
Actuator Travel...................25º
Case ...................................Dially phthalate (DAP) (UL 94V-0)
Slide Handle ......................Nylon
Housing .............................Stainless Steel
Terminal Seal .....................Epoxy
www.carlingtech.com
25
F-Series Single Pole Toggle Switches
F-Series Single Pole
Toggle Switches
General purpose workhorses with options tailored to meet
most any need. Ratings to 20A 277VAC, various actuator,
bushing, termination, and circuit choices allow this versatile
switch to easily integrate into a variety of different applications. The F-Series has a storied history in the Marine, Food
Service, Generator, Industrial Control, and Office Automation markets and is appropriate for usage in low voltage DC
applications as well.
Typical Applications: Military/Special Forces Vehicle
Controls, Auxiliary Lighting Compressors, General
Purpose Control Needs.
Dielectric Strength
UL/CSA:
1000V - live to dead metal
parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
0°F to 150°F (-17.8°C
to +65.6°C)
.075[1.91] DIA
.125[3.18] DIA
15/32-32UNS-2A
THREAD
.330[8.38]
.437[11.09]
.394[10.00]
.250[6.35]
.187[4.74]
.187[4.74]
KEYWAY
.072[1.82]
X
.038[.965] DP
SOLDER LUG
.687[17.44]
.055[1.40] DIA
.250 TAB (Q.C.)
.187 TAB (Q.C.)
TERMINAL TYPE
.465[11.81]
#6-32NC-2
THREAD
.670[17.02]
6.000[152.40]
.141[3.58]
.370[9.39]
.500[12.70]
.286[7.26]
.348[8.84]
1.134[28.80]
.634[16.10]
.500[12.70] DIA
SCREW
(ASSEMBLED)
.062[1.57]
.038[9.65]
MOUNTING HOLE
26
WITH KEYWAY
WIRE LEAD
.500[12.70] DIA
.376[9.55]
.500[12.70] DIA
.125[3.17] DIA
WITH LOCKING RING
www.carlingtech.com
G-Series Toggle Switches
G-Series
Toggle Switches
General purpose toggle switches with options tailored to
meet almost any need. Features such as ratings to 20A
277VAC, international approvals, various actuators, bushing,
termination, and circuit choices allow this toggle switch to
be easily integrated into a variety of different applications.
Typical Applications: Military/Special Forces Vehicle Controls, Auxiliary Lighting Compressors, General
Purpose Control Needs.
Dielectric Strength
UL/CSA: 1000V - live to
dead metal parts & opposite
polarity VDE: 4000V - live to
dead metal parts; 1250V opposite polarity & across
open contacts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 185°F (0° to 85°C)
.687[17.44]
.075[1.91] DIA
.125[3.18] DIA
15/32-32UNS-2A
THREAD
.330[8.38]
.187[4.74]
.465[11.81]
.437[11.09]
.394[10.00]
.250[6.35]
.187[4.74]
SOLDER LUG
.778[19.76]
.055[1.40] DIA
.250 TAB (Q.C.)
.187 TAB (Q.C.)
TERMINAL TYPE
1.308[33.22]
.422[10.72]
KEYWAY
.072[1.82]
X
.038[.965] DP
.778[19.76]
.490[22.86]
.075[1.905]
.750[19.05]
#6-32NC-2
THREAD
.370[9.39]
www.carlingtech.com
.187[4.75]
.500[12.70]
.286[7.26]
.350[8.89]
SCREW
(ASSEMBLED)
.500[12.70] DIA
.750[19.05]
IEC APPROVED CONSTRUCTION
.187[4.75]
6.000[152.40]
.141[3.58]
WIRE LEAD
.062[1.57]
.500[12.70] DIA
.038[9.65]
MOUNTING HOLE
WITH KEYWAY
PRINTED
CIRCUIT
.376[9.55]
.500[12.70] DIA
.125[3.17] DIA
WITH LOCKING RING
27
DK/EK-Series Heavy Duty Toggle Switches
DK/EK-Series Heavy Duty
The switch that can handle your heavy duty requirements.
Single or double pole with wire lead or screw terminations,
and ratings to 20A 125V 10A 250V, the ac/dc DK/EK-Series
is the most heavy duty toggle switch in the Carling line. Its
sturdy metal construction and stiff actuation force will withstand the abuses of virtually any stringent application. The
quick make/quick break contact mechanism is ideal for high
voltage DC applications. The DK/EK-Series has long been a
staple of the Industrial Motor control and General Purpose
market segments.
Typical Applications: General Purpose High Circuit, High
Voltage AC/DC Controls, Motor Controllers
Dielectric Strength
UL/CSA: 1000V - live
to dead metal parts &
opposite polarity
Electrical Life
25,000 cycles
Mechanical Life
100,000 cycles
Operating Temperature
0°F to 150°F (-17.8°C to
+65.6°C)
#6-32NC-2
THREAD
6.000[152.40]
.465[11.81]
KEYWAY
.072[1.82]
X
.038[.965]
.270[6.86]
15/32-32UNS-2A
THREAD (TYP)
.500[12.70]
.687[17.44]
.765[19.43]
TERMINAL TYPE
DK
SERIES
.836[21.23]
1.750[44.45]
1.764[44.80]
KEYWAY
.072[1.82]
X
.038[.965]
.038[9.65]
MOUNTING HOLE
WITH KEYWAY
.500[12.70] DIA
.125[3.17] DIA
WITH LOCKING RING
EK
SERIES
.895[22.73]
28
.376[9.55]
.062[1.57]
.500[12.70] DIA
.500[12.70] DIA
.465[11.81]
.687[17.44]
1.000[25.40]
SCREW
(ASSEMBLED)
WIRE LEAD
2.093[53.16]
www.carlingtech.com
World-Wide
Corporate Headquarters
60 Johnson Avenue
Plainville, CT 06062
860/793-9281
Fax: 860/793-9231
E-mail: [email protected]
www.carlingtech.com
Europe/Middle East/Africa
Carling Technologies Ltd.
Devon, England
Int + 44 (0)1392-364422
Fax: Int + 44 (0)1392-364477
E-mail: [email protected]
Asia/Pacific
Carling Technologies Asia-Pacific Ltd.
Kowloon, Hong Kong
Int + 852-2737-2277
Fax: Int + 852-2736-9332
E-mail: [email protected]
Additional Carling Technologies Offices
East Region Sales Office, CT
[email protected]
Midwest Region Sales Office, IL
[email protected]
West Region Sales Office, CA
[email protected]
GmbH, Germany
[email protected]
SARL, France,
[email protected]
Asia-Pacific Ltd., Shanghai, China
[email protected]
Asia-Pacific Ltd., Japan
[email protected]
Pune, India
[email protected]
Kaohsiung, Taiwan
[email protected]
®
Moritz Aerospace, Inc.
2317 Topaz Drive
Hatfield, PA 19440
215/996-9211
Fax: 215/996-0945
E-mail: [email protected]
www.moritzaero.com
Maretron, LLC
9014 N. 23rd Avenue
Suite 10
Phoenix AZ 85021
Phone: (602) 861-1707
Fax: (602) 861-1777
[email protected]
www.maretron.com