DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-DA0602-05(S) (30 W SIXFOLD OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for sextuple lamps.
APPLICABLE LCD:
15 to 30 inches sextuple lamp type
Lamp Voltage 833 Vrms
Lamp Current 6 x 6.0 mArms
Lamp Start Up Voltage 1.650 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +60°C
-20°C ~ +85°C
95 %RH max
170 x 60 x 10.5 mm
Pin 1
Pin 1
Pin 1
Unit : mm
Weight :64 (g) typ.
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 ~ CN7
Qty.
1
1
6
Material
UL94V-0 (FR-4 or CEM-3)
S8B-PH-SM3-TB
SM02B-BHSS-1-TB
Input side CN1:
Pin No.
Symbols
Ratings
Vin
10.8
~ 13.2 Vdc
CN 1-1+2+3
GND
CN 1-4+5+6
Vbr
0 ~ 3 Vdc
CN 1-7
Vrm t
0 ~ 1.5 = OFF / 2.5 ~ 5.5 = ON
CN 1-8
Note
t=1m m
JST or equal
JST or equal
Output side CN2 ~ CN7
Pin No.
CN 2-1
CN 2-2
Symbols
Vhigh
Vlow
Ratings
833 Vrm s (6.0 m Arm s )
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.4.1. 08th September 2010
DC-AC INVERTER UNIT
PS-DA0602-05(S) (30 W SIXFOLD OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Iout
12±1.2
5±0.25 0 ~ +60
Iout
Iin
F
Vopen
12±0.6
12±1.2
12±1.2
11.4
5±0.25
5±0.25
5±0.25
5±0.25
Ts d
12±1.2
5±0.25 0 ~ +60
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Note 1:
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
0
0
0
0
Specification
~ +60
~ +60
~ +60
~ +60
Unit
Note
7.0
m Arm s
V in = 12 V dc
V dim =0 V
Dut y = 10 0%
20
2.4
50
1.650
3.4
60
1.900
%
Adc
kHz
Vrm s
V d im = 3.0 V
1.0
-
s ec
wit hout load
Min.
Typ.
Max.
-
6.0
40
1.500
-
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
Note 2:
TEST CIRCUIT :
F
A
Vin
12 V
Iin
1000:1
PROBE
F
Vopen
CN2-1
CN1-1
CN1-2
CN1-3
V
SW3
CL1
RL1
CN2-2
SW4
A
~
Iout
1
A
~
CL2
Iout
2
A
~
CL3
Iout
3
A
~
CL4
Iout
4
A
~
CL5
Iout
5
A
~
CL6
Iout
6
SW5
V
~
SW 1
Operation of unit
a
Operation
b
Non operation
CN3-1
RL2
T1
CN3-2 SW6
SW7
CN1-4
CN1-5
CN1-6
CN4-1
RL3
SW8
CN4-2
SW9
CN5-1
RL4
CN1-7
CN5-2 SW10
SW11
CN6-1
Vbr
0 ~ 3 Vdc
RL5
Vrmt
0.4 / 5 Vdc
a
V
b
CN6-2 SW12
SW13
CN7-1
CN1-8
SW1
RL6
CN7-2 SW14
Dimming Characteristic:
100
Iout (in %)
80
60
40
20
0
0
1
2
3
4
5
Vbr (VDC)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 2.4.1. 08th September 2010