G3VM-353H MOS FET Relays Analog-switching MOS FET Relays with SPST-NC Contact. • Models in 350-V load voltage series with SPST-NC contacts and SOP 6-pin package. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections 6 • Semiconductor test equipment 5 4 • Test & Measurement equipment OMRON logo • Communication equipment Model name 932 Pin 1 mark LOT.No. • Data loggers 1 3 2 Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form SOP6 1b (SPST-NC) Load voltage (peak value) * Terminals Surface-mounting Terminals 350 V Model Minimum package quantity Number per tube Number per tape and reel G3VM-353H G3VM-353H (TR) 75 - - 2,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Connection A Continuous Connection B load current Connection C Connection A ON current reduction Connection B rate Connection C Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF IFP ∆IF/°C VR TJ VOFF Unit mA A mA/°C V °C V TJ Rating 50 1 −0.5 5 125 350 120 120 240 −1.2 −1.2 −2.4 125 VI-O 1500 Vrms Ta Tstg - −40 to +85 −55 to +125 260 °C °C °C IO ∆IO/°C mA mA/°C Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Connection Diagram Connection A Connection A: AC peak/DC Connection B and C: DC Ta ≥ 25°C Connection B °C AC for 1 min With no icing or condensation With no icing or condensation 10 s Connection C 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 Load or AC DC Load DC Load DC Output Input ■ Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum LED forward voltage VF 1.0 1.15 1.3 Reverse current IR 10 Capacity between terminals CT 30 Trigger LED forward current IFC 1.0 3.0 Connection A 15 25 Maximum Connection B RON 8 14 resistance with output ON Connection C 4 Current leakage when the relay is open ILEAK 1.0 Unit V µA pF mA Ω Ω Ω µA Capacity between terminals COFF - 65 - pF Capacity between I/O terminals Insulation resistance between I/O terminals Turn-ON time Turn-OFF time CI-O RI-O tON tOFF 1000 - 0.8 - 1.0 3.0 pF MΩ ms ms Measurement conditions IF = 10 mA VR = 5 V V = 0, f = 1 MHz IOFF = 10 µA Note: 2. Turn-ON and Turn-OFF Times IO = 120 mA IO = 120 mA IO = 240 mA VOFF = 350 V, IF = 5 mA V = 0, f = 1 MHz, IF = 5 mA f = 1 MHz, Vs = 0 V VI-O = 500 VDC, ROH ≤ 60 % IF = 5 mA, RL = 200 Ω, VDD = 20 V (See note 2.) 1 G3VM-353H MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta 5 −20 - 280 25 120 65 V mA mA °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 100 80 60 40 IF - VF 280 LED forward current IF (mA) Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 240 200 160 120 100 Ta = 25°C 50 30 10 5 3 1 80 0.5 20 0.3 40 0.1 0 0 -20 0 20 40 60 80 100 20 120 0 20 40 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 100 120 0.6 100 0 1 IO = 120 mA t<1s Connection A 15 10 0 20 40 60 80 100 Turn ON, Turn OFF time vs. Ambient temperature 4 3 2 1 -40 -20 0 VDD = 20 V, RL = 200 Ω tOFF 500 300 tON 100 50 40 60 80 100 Current leakage vs. Ambient temperature ILEAK - Ta 1200 VDD = 20 V, RL = 200 Ω IF = 5 mA 20 Ambient temperature Ta (°C) Current leakage ILEAK (nA) Turn ON, Turn OFF time tON, tOFF (µs) Ta = 25°C 1.8 IOFF = 10 µA tON, tOFF - Ta tON, tOFF - IF 2000 1000 5 Ambient temperature Ta (°C) On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current 1.6 0 -20 2 1.4 IFC - Ta 20 0 -200 0 1.2 Trigger LED forward current vs. Ambient temperature 5 -100 -1 1 LED forward voltage VF (V) Trigger LED forward current IFC (mA) Ta = 25°C Connection A -2 0.8 RON - Ta 200 On-state resistance RON (Ω) Continuous load current IO (mA) 80 On-state resistance vs. Ambient temperature IO - VON Turn ON, Turn OFF time tON, tOFF (µs) 60 Ambient temperature Ta (°C) tOFF 1000 800 600 1000 VOFF = 350 V IF = 5 mA 100 10 400 tON 200 30 1 3 5 10 30 50 100 1 0 -40 -20 LED forward current IF (mA) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 0 20 40 60 80 100 Ambient temperature Ta (°C) 0 20 40 60 80 100 Ambient temperature Ta (°C) Appearance/Dimensions SOP6 type ■ Appearance SOP (Small Outline Package) SOP6 OMRON logo Model name 932 Pin 1 mark LOT.No. Note: The actual product is marked differently from the image shown here. ■ Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.13 g 4.4±0.25 (Recommended Value, TOP VIEW) 2.1 max. 6.3±0.25 6 to 6.3 1.2 0.15 0.8 2.54±0.25 0.1±0.1 0.4±0.1 Note: The actual product is marked differently from the image shown here. 0.6±0.3 7.0±0.4 2.54 2.54 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K253-E1-01 0413(0413)(O)