G3VM-61A1/D1 MOS FET Relays Compact, General-purpose, Analog switching MOS FET Relays, with Dielectric Strength of 2.5 kVAC between I/O Using Optical Isolation. • Upgraded G3VM-61A/D Series. • Switches minute analog signals. • Leakage current of 1 µA max. when output relay is open. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections • Test & Measurement equipment 4 • Security equipment 3 Mold pin mark * OMRON logo • Amusement equipment Model name Pin 1 mark 1 932 LOT.NO. 2 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ List of Models Package type Contact form Load voltage (peak value) * Terminals PCB Terminals DIP4 1a (SPST-NO) Model G3VM-61A1 60 V Surface-mounting Terminals G3VM-61D1 G3VM-61D1(TR) Minimum package quantity Number per tube Number per tape and reel 100 - - 1,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF IFP ∆IF/°C VR TJ VOFF IO ∆IO/°C TJ VI-O Ta Tstg - Rating 50 1 −0.5 5 125 60 500 −5.0 125 2500 −40 to +85 −55 to +125 260 Unit mA A mA/°C V °C V mA mA/°C °C Vrms °C °C °C Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Ta ≥ 25°C AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.0 1.15 1.3 Reverse current IR 10 Capacity between terminals CT 30 Trigger LED forward current IFT 1.6 3 Maximum resistance with output ON RON 1 2 Current leakage when the relay is open ILEAK 1.0 Capacity between terminals COFF 130 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 0.8 2.0 Turn-OFF time tOFF 0.1 0.5 1 Unit V µA pF mA Ω µA pF pF MΩ ms ms Measurement conditions IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times VR = 5 V IF 1 4 RL VDD V = 0, f = 1 MHz VOUT 2 3 IO = 500 mA IF = 5 mA, IO = 500 mA VOFF = 60 V V = 0, f = 1 MHz IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60% 90% VOUT 10% IF = 5 mA, RL = 200 Ω, t ON t OFF VDD = 20 V(See note 2.) G3VM-61A1/D1 MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta 5 −20 7.5 - 48 25 500 65 V mA mA °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 80 60 40 20 0 -20 0 20 40 60 80 100 500 400 300 0 20 40 100 0 IO = 500mA IF = 5mA 4 3 2 0.4 0.6 -20 0 20 Turn ON, Turn OFF time vs. LED forward current tON, tOFF - IF 60 80 VDD = 20V RL = 200Ω 1000 500 300 tOFF 100 tON 1000 300 tOFF 100 30 3 2 1 0 20 50 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Ambient temperature 30 VOFF = 60V 10 3 1 0.3 VDD = 20V RL = 200Ω IF = 5mA 10 30 t < 1s ILEAK - Ta 3000 tON 10 1.8 4 0 -20 100 Current leakage ILEAK (nA) Turn ON, Turn OFF time tON, tOFF (µs) Ta = 25°C 1.6 IO = 500mA tON, tOFF - Ta 3000 1.4 5 Ambient temperature Ta (°C) Turn ON, Turn OFF time vs. Ambient temperature 5000 50 40 1.2 LED forward voltage VF (V) 0 0.2 On-state voltage VON (V) 5 1 IFT - Ta 5 1 3 0.8 Trigger LED forward current vs. Ambient temperature -200 1 0.1 0.6 120 Trigger LED forward current IFT (mA) On-state resistance RON (Ω) Continuous load current IO (mA) 80 RON - Ta -400 Turn ON, Turn OFF time tON, tOFF (µs) 60 On-state resistance vs. Ambient temperature 200 30 3 Ambient temperature Ta (°C) 400 0 10 0.3 IO - VON -0.2 30 100 0 -20 Ta = 25°C IF = 5mA -0.4 Ta = 25°C 1 120 600 -600 -0.6 100 200 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage IF - VF 600 LED forward current IF (mA) 100 Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 100 300 0.1 -20 0 LED forward current IF (mA) 20 40 60 80 100 Ambient temperature Ta (°C) -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions DIP4 type ■ Appearance DIP (Dual Inline Package) DIP4 Mold pin mark * OMRON logo Model name Pin 1 mark 932 LOT.NO. Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ Dimensions (Unit:mm) PCB Terminals Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) Weight: 0.25 g Weight: 0.25 g Four, 0.8-dia. holes 2.54 (0.61) 2.54 4.58±0.25 4.58±0.25 6.4±0.25 (0.61) (1.52) (1.52) 6.4±0.25 Actual Mounting Pad Dimensions 7.62±0.25 7.62±0.25 0.8±0.25 (Recommended Value, TOP VIEW) +0.15 3.65 -0.25 0.25 +0.1 -0.05 2.5 min. 1.0 min. 1.2±0.15 0.5±0.1 2.54±0.25 2.54 4.0 +0.25 -0.2 3.65 +0.15 -0.25 7.85 to 8.80 1.2±0.15 2.54±0.25 Note: The actual product is marked differently from the image shown here. 1.0 min. 8.3 to 8.8 10.0 max. 1.3 1.5 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K143-E1-01 0412(0412)(O)