TPSPU60 SERIES

Total Power International, Inc.
Tota
TPSPU60 SERIES
60W Desk Top Type
I.T.E. Power Supplies
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Over Voltage Protection (Crowbar Design)
Optional Output Connector (See page appendix)
Single Output
Energy Star 2.0, Efficiency level V
Class I
2 year warranty
Electrical Characteristics:
Safety Approvals Input Voltage Range
100~240VAC
Operate Voltage Range
90~264VAC
fin
Input Frequency
47~63Hz
Po
Output Power Range
See rating chart
Vo
Output Voltage Range
See rating chart
Io
Output Current Range
Iil
Input Current (Low Line)
Io=Full load, Vin=100VAC
1.6A
Iih
Input Current (High Line)
Io=Full load, Vin=240VAC
1.0A
Low Line Inrush Current
Io=Full load, 25°C, Cool start, Vin=115VAC
42A (max.)
High Line Inrush Current
Io=Full load, 25°C, Cool start, Vin=230VAC
85A (max.)
Efficiency
Io=Full Load, Vin=230VAC
75~90%
Line Regulation
Io=Full Load
0.5~1%
Vin=230VAC
3~7%
Vin
Ir
Eff
REG-i
REG-o Load Regulation
See rating chart
OVP
Over Voltage Protection
112~132%
OCP
Over Current Protection
110~150%
Ttr
Time of Transient Response
Io=Full Load to Half Load, Vin=100VAC
4mS (max.)
Th
Hold-Up Time
Io=Full Load, Vin=110VAC
16mS (min.)
Ts
Start Up Time
Io=Full Load, Vin=100VAC
2S (max.)
Ripple & Noise(Peak to Peak)
Full Load, Vin=90VAC
1% (max.)
Vp-p
Ilk
Safety Ground Leakage Current
Vin=240VAC/60Hz
0.75mA (max.)
TC
Temperature Coefficient
All output
±0.04%/°C
Pno
No-Load Power Consumption
No load, Vin=230VAC
See rating chart
Primary to secondary
4242VDC (min.)
Primary to PE
2594VDC (min.)
Test Voltage=500VDC
50M
Vps
Vpg
Ris
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
for Primary to PE
Isolation Resistance
Application:
- POS System
- AV Equipment
- Industrial PC
- Note PC
- Charger
- LED Lighting
Safety Approvals:
S&E
RoHS
2002/95/EC
COMPLIANT
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
The TPSPU60-108 is
available with KC mark
(Korea Certification).
(min.)
Note: The Ripple & Noise which is under 3.3VDC at 2% max
Environmental
To
Operating Temperature
See derating curve
Ts
Storage Temperature
-40~85°C
Ho
Operating Humidity
0~95%
Hr
Storage Humidity
0~95%
Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
0.1M Hrs (min.)
MTBF
Pd
Derate linearly from 100% load at 40°C to 50% load at 70°C
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
TPSPU60 SERIES
60W Desk Top Type
I.T.E. Power Supplies
Output Voltage And Current Rating Chart ( Single Output ) :
Output Voltage
Output Current
Total
Regulation
Max .
Output Power
Pno (max.)
TPSPU60-101
3 ~ 5 VDC
6.60 ~ 4.00 A
7%
20W
0.5W
TPSPU60-102
5 ~ 6 VDC
6.00 ~ 5.00 A
5%
30W
0.5W
TPSPU60-103
6 ~ 8 VDC
5.83 ~ 4.37 A
5%
35W
0.5W
TPSPU60-104
8 ~ 11 VDC
5.00 ~ 3.63 A
5%
40W
0.5W
TPSPU60-105
11 ~ 13 VDC
4.54 ~ 3.84 A
5%
50W
0.5W
TPSPU60-105-1
11 ~ 13 VDC
5.45 ~ 4.61 A
5%
60W
0.5W
TPSPU60-106
13 ~ 16 VDC
4.23 ~ 3.43 A
5%
55W
0.5W
TPSPU60-107
16 ~ 21 VDC
3.75 ~ 2.85 A
5%
60W
0.5W
TPSPU60-108
21 ~ 27 VDC
2.85 ~ 2.22 A
5%
60W
0.5W
TPSPU60-109
27 ~ 33 VDC
2.22 ~ 1.81 A
5%
60W
0.5W
TPSPU60-110
33 ~ 40 VDC
1.81 ~ 1.50 A
3%
60W
0.5W
40 ~ 50 VDC
1.50 ~ 1.20 A
3%
60W
0.5W
Model Number
TPSPU60-111
TPSPU60-105-1 is required to use AWG#16/4FT,UL2464 output cable.
TPSPU60-105,106~107 are required to use AWG#16/4FT,UL1185 output cable.
TPSPU60-108~111 are required to use AWG#18/4FT,UL1185 output cable.
Mechanical Specifications:
Note:
1. Dimensions are shown in mm.
2. Weight: 340gs approx.
3. Optional output connector:
See page Appendix.
Derating Curve :
1. Operating Temperature: 0 to 70°C
2. Derate linearly from 100% load at 40°C to 50%
load at 70°C
120%
Output Watts (%)
100%
80%
60%
40%
20%
0%
0
10
20
30
40
50
60
70
80
Temperature (deg c)
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com