48 Port Consolidation Point Box

48 Port Consolidation Point Box
Part Numbers: CUFB48BL, CUFF-KIT
PN232B INSTALLATION INSTRUCTIONS
© Panduit Corp. 2001
Printed in U.S.A.
1.0 COMPONENT IDENTIFICATION
PARTS
CUFB48BL
(1)
(1)
(4)
(6)
(4)
(2)
Metal Box
Cover
TAK-TY™
Adapter Plates (removable)
Pass Thru Plates (with screws)
Rubber Grommets for Pass
Thru Plates
(1) 48 Port Identification Label
(2) Plungers
(2) Grommets for Plungers
The 48 Port Consolidation Point Box is designed for use with raised floor products including SMED “Nexus”
underfloor systems. This zone product can also be wall mounted.
2.0 Box Assembly
2.1 Set box on flat work surface. Snap the (6) Adapter Plates in place, then snap properly terminated MINI-COM®
modules in place. MINI-COM modules mount side by side vertically in the Adapter Plates.
2.2 Position cables into either side of the box and secure them with the TAK-TYS provided to the raised tabs in the
floor of the box. If cables enter one end of the box, then install (1) Pass Thru Plate to seal off the opposite end
of the box. To assemble the Pass Thru Plate, slide the (2) Grommets into the slots of the Pass Thru Plate,
then fasten the plate to box the with screws provided.
Adapter Plate
locator holes
Adapter Plate (removable)
(can be rotated 180°)
2.1
Grommets
TAK-TY
Pass Thru
Plate
Box
2.2
Enclosure
Copper cable
3.0 Cover Assembly
3.1 Install the Grommet into the locating hole in the cover tab, then
push the Plunger into the Grommet until it snaps into place.The
face of the Grommet remains between the outside face of the tab
and the plunger head.
3.2 To install the cover, slide the cover into channel and push back
until the tabs engage, then push in both Plungers to secure the
cover. To remove the cover, pull out on both Plungers, then slide
Cover tab
and lift cover out.
3.3 Apply the Port Identification Label on the bottom side of the cover. 3.0
FOR TECHNICAL SUPPORT CALL: 866-405-6654
Page 1 of 2
Plunger
Grommet
PN232B INSTALLATION INSTRUCTIONS
4.0 FIBER CONVERSION KIT (Sold Separately)
PARTS:
CUFF-KIT
(2) Spools with Adhesive Backing
(2) Strain Relief Clips
(1) Grounding Lug
(1) Fiber Laser Beam Warning Label
(4) Wire Saddles
(1) Fiber Caution Label
(1) Spiral Wrap 24” long
(4) Panduit Cable Ties
Notes: 1. Kit works with both CUFB48BL and CUFMB24BL.
2. Depending on the product being assembled for use with fiber, some kit components may be left over.
5.0 Installation of Fiber Cable
5.1 Install (2) Pass Thru Plates into the box.
5.2 Bring (1) meter of buffered fiber into the box. Strip back the cable jacket. Secure the cable to the strain relief
with the cable tie provided. The cable can enter from either side of the box.
5.3 Attach the fiber to the connector. Use the spools to maintain proper bend radius for fiber slack.
5.4 Attach the kevlar to the Grounding Lug (either location) for strain relief.
Cable
Kevlar
5.5 Use TAK-TYS™ to secure the fiber to the raised tabs in the floor of the box.
Note: Copper and fiber terminated products can be installed together in this box.
Grounding Lug
Fiber Spool
TAK -TY
Cable Tie
Strain Relief Bracket
Cable
Pass Thru Plate
Grounding Lug
(Optional location)
Adapter Plates (removable)
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
NETWORK CONNECTIVITY GROUP
10500 West 167th Street
Orland Park, Illinois 60467
Technical Support: 866-405-6654
Fax: 708-444-6993
Page 2 of 2
Web site: www.panduit.com/ncg
E-mail: [email protected]