Features LED DRIVER ● ● ● ● ● ● Universal AC Input Constant Voltage / Constant Current Operation CE and UL Certified Class I LED Driver Active Power Factor Correction IP67 Design for Indoor and Outdoor Use Cooling by Free Air Convection LIGHTLINE AC/DC-Converter with 5 year Warranty Selection Guide Part Number CV Mode Constant Voltage Current Range (V) (A) CC Mode Efficiency DC Voltage Range Constant Current (230VAC) (V) (A) (%) RACD100-12 12 0-8.3 9-12 8.3 88 RACD100-24 24 0-4.2 14-24 4.2 90 RACD100-36 36 0-2.8 26-36 2.8 90 RACD100-48 48 0-2.1 34-48 2.1 91 100 Watt Single Output Specifications Input Voltage Range Input Frequency Range Power Factor 90-305 VAC or 127-430VDC 47-63Hz. Full Load, 115VAC >0.98 Full Load, 230VAC >0.95 Full Load, 277VAC >0.94 THD Full Load, 115VAC 8% max. AC Current 115VAC 1.4A max. 230VAC 0.7A max. Input/Output Isolation 3.75kVAC / 1minute Input/Case Isolation 1.8kVAC / 1minute Output/Case Isolation 0.5kVAC / 1minute Leakage Current 240VAC <0.75mA Voltage Tolerance -1% to 5% Start-up Time 115VAC 1.5s (@ Full Load) 230VAC / 277VAC 0.7s Ripple & Noise 48V Version 200mV max. others 150mV max. Over Current Protection 95%-105% rated current Auto-Recovery Short Circuit Protection Hiccup Mode Over Voltage Protection 12V 15V typ. Latch Mode 24V 31V typ. (Power off to recover) 36V 45V typ. 48V 58V typ. Over Temperature Protection Tcase 95°C ±10°C Operating Temperature Range without derating -20°C to +50°C (see graph) (free air convection, according to CE/UL) Case Temperature 90°C max. Operation Humidity 20%-90% RH Non-Condensing Storage Temperature -40°C to +80°C Storage Humidity 10%-90% RH Vibration 10-500Hz, 2G, 60 Min. along X, Y and Z IP Rating IP67 Safety Standards UL/cUL LED Lighting Safety (E340696) UL8750 CE LVD Directive, Safety EN61347-2-13 CB Report: 12CA61289-1 IEC61347-2-13 EMC Standards EMC Compatibility EN55015 FCC, Part 15 Harmonic Current EN61000-3-2 Class C (≥75% load) EN61000-3-3 EMC Immunity EN61000-4-2, 3, 4, 5, 6, 11 continued on next page L-56 REV: 1/2015 RoHS 2011/65/EU 6/6 E340696 UL 8750 Certified EN 61347 Certified RACD100 Note: All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. Refer to Application Notes www.recom-power.com RACD100 Series LIGHTLINE AC/DC-Converter Specifications Dimension Weight MTBF Design Lifetime The use of a circuit breaker with C-characteristic is recommended. 222*68*39mm 1020g 250 x 10³ hours 70 x 10³ hours using MIL-HDBK-217F (25°C) Derating Curves Load Load 100% Ta=25°C 100% 80% 80% 60% 60% 40% 40% 20% 20% -20 -10 10 30 50 70 90 100 130 180 240 220 300 Input Voltage (VAC)60Hz Ambient Temperature (°C) Typical Characteristics Constant Voltage / Constant Current Curve RACD100-24 RACD100-12 CV Vout 12 (nom) CV Vout (nom) 24 CC Vout (min) 26 4.2 Iout 0 CC Vout (min) 34 2.8 Iout 0 2.1 Iout 0 RACD100 Vout (min) 14 CV Vout (nom) 48 CC 8.3 Iout 0 RACD100-48 CV Vout (nom) 36 CC Vout (min) 9 RACD100-36 Maximum Number of LED drivers per circuit breakers Condition Circuit Breaker Circuit Breaker Current Typ 10A 16A 20A 25A 115VAC, 1Ohm 90° phase angle C 7 12 14 18 230VAC, 1Ohm 90° phase angle B C 6 13 10 22 12 24 14 31 277VAC, 1Ohm 90° phase angle B C 7 15 11 25 14 29 17 36 Package Style and Pinning 222.0 11.4 7.0 300±20 AC/L (Brown) AC/N (Blue) Earth (Green/Yellow) 10±3 199.2 8.9 34.2 8.9 34.0 99.6 Tc 68.0 300±20 16AWG +V(Red) -V(Black) 14AWG for RACD100-12 35±5 35±5 10±3 39.0 The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 1/2015 L-57