RACD100 - recom

Features
LED DRIVER
●
●
●
●
●
●
Universal AC Input
Constant Voltage / Constant Current Operation
CE and UL Certified Class I LED Driver
Active Power Factor Correction
IP67 Design for Indoor and Outdoor Use
Cooling by Free Air Convection
LIGHTLINE
AC/DC-Converter
with 5 year Warranty
Selection Guide
Part
Number
CV Mode
Constant Voltage
Current Range
(V)
(A)
CC Mode
Efficiency
DC Voltage Range Constant Current (230VAC)
(V)
(A)
(%)
RACD100-12
12
0-8.3
9-12
8.3
88
RACD100-24
24
0-4.2
14-24
4.2
90
RACD100-36
36
0-2.8
26-36
2.8
90
RACD100-48
48
0-2.1
34-48
2.1
91
100 Watt
Single
Output
Specifications
Input Voltage Range
Input Frequency Range
Power Factor
90-305 VAC or 127-430VDC
47-63Hz.
Full Load, 115VAC
>0.98
Full Load, 230VAC
>0.95
Full Load, 277VAC
>0.94
THD
Full Load, 115VAC
8% max.
AC Current
115VAC
1.4A max.
230VAC
0.7A max.
Input/Output Isolation
3.75kVAC / 1minute
Input/Case Isolation
1.8kVAC / 1minute
Output/Case Isolation
0.5kVAC / 1minute
Leakage Current
240VAC
<0.75mA
Voltage Tolerance
-1% to 5%
Start-up Time
115VAC
1.5s
(@ Full Load)
230VAC / 277VAC
0.7s
Ripple & Noise
48V Version
200mV max.
others
150mV max.
Over Current Protection
95%-105% rated current
Auto-Recovery
Short Circuit Protection
Hiccup Mode
Over Voltage Protection
12V
15V typ.
Latch Mode
24V
31V typ.
(Power off to recover)
36V
45V typ.
48V
58V typ.
Over Temperature Protection
Tcase 95°C ±10°C
Operating Temperature Range
without derating
-20°C to +50°C (see graph)
(free air convection, according to CE/UL) Case Temperature
90°C max.
Operation Humidity
20%-90% RH Non-Condensing
Storage Temperature
-40°C to +80°C
Storage Humidity
10%-90% RH
Vibration
10-500Hz, 2G, 60 Min. along X, Y and Z
IP Rating
IP67
Safety Standards
UL/cUL LED Lighting Safety (E340696)
UL8750
CE LVD Directive, Safety
EN61347-2-13
CB
Report: 12CA61289-1
IEC61347-2-13
EMC Standards
EMC Compatibility
EN55015
FCC, Part 15
Harmonic Current
EN61000-3-2 Class C (≥75% load)
EN61000-3-3
EMC Immunity
EN61000-4-2, 3, 4, 5, 6, 11
continued on next page
L-56
REV: 1/2015
RoHS
2011/65/EU
6/6
E340696
UL 8750 Certified
EN 61347 Certified
RACD100
Note:
All LED Drivers may not be used without a load.
They must be switched on the primary side
only. Noncompliance may damage the LED or
reduce its lifetime.
Refer to Application Notes
www.recom-power.com
RACD100
Series
LIGHTLINE
AC/DC-Converter
Specifications
Dimension
Weight
MTBF
Design Lifetime
The use of a circuit breaker with C-characteristic is recommended.
222*68*39mm
1020g
250 x 10³ hours
70 x 10³ hours
using MIL-HDBK-217F (25°C)
Derating Curves
Load
Load
100%
Ta=25°C
100%
80%
80%
60%
60%
40%
40%
20%
20%
-20
-10
10
30
50
70
90
100
130
180
240
220
300
Input Voltage (VAC)60Hz
Ambient Temperature (°C)
Typical Characteristics
Constant Voltage / Constant Current Curve
RACD100-24
RACD100-12
CV
Vout 12
(nom)
CV
Vout
(nom) 24
CC
Vout
(min) 26
4.2
Iout
0
CC
Vout
(min) 34
2.8
Iout
0
2.1
Iout
0
RACD100
Vout
(min) 14
CV
Vout
(nom) 48
CC
8.3
Iout
0
RACD100-48
CV
Vout
(nom) 36
CC
Vout
(min) 9
RACD100-36
Maximum Number of LED drivers per circuit breakers
Condition
Circuit Breaker
Circuit Breaker Current
Typ
10A
16A
20A
25A
115VAC, 1Ohm
90° phase angle
C
7
12
14
18
230VAC, 1Ohm
90° phase angle
B
C
6
13
10
22
12
24
14
31
277VAC, 1Ohm
90° phase angle
B
C
7
15
11
25
14
29
17
36
Package Style and Pinning
222.0
11.4
7.0
300±20
AC/L (Brown)
AC/N (Blue)
Earth (Green/Yellow)
10±3
199.2
8.9
34.2
8.9
34.0
99.6
Tc
68.0
300±20
16AWG
+V(Red)
-V(Black)
14AWG
for RACD100-12
35±5
35±5
10±3
39.0
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 1/2015
L-57