RACD45-A - recom

●
●
●
●
Features
LED DRIVER
●
●
●
Constant Current Operation
Suitable for High Brightness LED Products
Built-In Active PFC Function
Overvoltage-, Short Circuit- and Overtemperature Protection
Built-In 3 in 1 Dimming
IP67 Rated
Class 2 Power Unit UL1310
LIGHTLINE
AC/DC-Converter
with 5 year Warranty
Selection Guide
Part
Number
Output
Voltage
(VDC)
Rated
Power
(W)
Rated
Current
(mA)
Output
Voltage Range
(V)
Efficiency
RACD45-700A
57
40
70 - 700
40 - 57
87%
RACD45-1050A
48
48
105 - 1050
33 - 48
87%
RACD45-1250A
36
45
125 - 1250
24 - 36
86%
RACD45-1850A
24
45
185 - 1850
15 - 24
85%
(typ.)
45 Watt PFC
Single
Output
Specifications (measured at 230VAC and 25°C ambient temperature)
Input Voltage Range
Input Frequency Range
Power Factor (Full Load)
L-48
REV: 0/2015
RoHS
2011/65/EU
6/6
E340696
EN 61347-1 Certified
EN 61347-2-13 Certified
UL8750 Certified
RACD45-A
Derating-Graph
(Ambient Temperature)
Load
100%
90%
75%
60%
40%
230VAC only
90-305 VAC
47-63Hz
120VAC
>0.98
240VAC
>0.93
277VAC
>0.90
THD
Full Load, 115VAC
13% max.
Full Load, 230VAC
19% max.
DC Dimming
Open = 100%
DC 1-10V
PWM Dimming
Open = 100%
Duty 10% - 100%
Freq.
500Hz - 3000Hz
Voltage
Hi=10V, Low=0V
Resistance Dimming
10K - 100K Ω
Current Accuracy
±5%
AC Input Current
100-240VAC
0.6A
277VAC
0.25A
Inrush Current (Cold Start)
240VAC
70A
Leakage Current
<0.5mA / 240VAC
Start-up Time (at Full Load)
<2sec
Isolation Voltage
3.75kVAC / 1 minute
Short Circuit Protection
Hiccup
Over Voltage Protection
24V
26.4 - 31.2V
36V
39.6 - 46.8V
48V
52.8 - 62.4 V
57V
62.7 - 70V
Over Temperature Protection
Latch Mode
105 ± 10°C
Vibration
10-500Hz, 2G, 60Min. along X, Y and Z
Storage Humidity
10% - 90% RH
Operating Humidity
20% - 90% RH Non-Condensing
Weight
420g
Operating Temperature
-30°C to +50°C
Storage Temperature
-40°C to +60°C
Ripple & Noise
24V
200mV
(at 20MHz bandwith using 0.1uF & 47uF capacitor)
all others
250mV
IP Rating
IP67
Isolation Resistance
100MΩ / 500VDC at 25°C
Dimension (L*W*H)
179*45.1*32.5mm
continued on next page
20%
-30
0
20
50 65
Ambient Temperature (°C)
Note:
All LED Drivers may not be used without a load.
They must be switched on the primary side only.
Noncompliance may damage the LED or reduce
its lifetime.
Refer to Application Notes
www.recom-power.com
RACD45-A
Series
LIGHTLINE
AC/DC-Converter
Specifications (measured at 230VAC and 25°C ambient temperature)
Safety Standards
LED Lighting Safety
LED Lighting Safety (Canada)
Class 2 Power Supply Safety
Extra Low-Voltage Class 2 Output
LED equipment for lighting application
Design Lifetime
MTBF (+25°C)
Report: E340696
Report: E340696
Report: E340696
Report: E340696
Report: E340696
UL8750
cUL8750
UL1310
CSA C22.2 No. 223-M91
CSA C22.2 No. 250.13-12
EN61347-1
EN61347-2-13
EN61000-3-2 Class C
EN61000-3-3
EN61000-4-2,3,4,5,6,8,11
EN61547
EN55015 FCC15
70 x 10³ hours max.
200 x 10³ hours min.
using MIL-HDBK 217F
3 in 1 Dimming Control (DC / PWM / Resistance)
10K-100K Resistor Dimmable (Typical):
Resistor
Single-Driver
Multi-Driver
Iout (%)
10K
10K/N
10%
20K
20K/N
20%
30K
30K/N
30%
40K
40K/N
40%
50K
50K/N
50%
60K
60K/N
60%
70K
70K/N
70%
80K
80K/N
80%
90K
90K/N
90%
100K
100K/N
100%
The length of extended wire for DIM+/- shall not exceed 20 meters. (wire ≤ 20m)
N = The number of dimmer drivers should not exceed 15. (N ≤ 15mS)
DC: 1-10V Dimmable (Typical)
Maximum Number of LED drivers per circuit breakers
80
60
Condition
40
Circuit Breaker
20
0
0
2
4
6
8
10
115VAC, 1Ohm
90° phase angle
Control Voltage (V)
Circuit Breaker Current
Typ
10A
16A
20A
25A
C
16
28
31
43
B
17
28
33
41
C
24
39
47
57
B
20
32
38
47
C
28
44
54
66
RACD45-A
Output Current (%)
100
DC: 10V / PWM Dimmable (Typical)
Output Current (%)
100
230VAC, 1Ohm
90° phase angle
80
60
40
20
0
0
20
40
60
80
277VAC, 1Ohm
90° phase angle
100
Duty Cycle (%)
Package Style & Pinning
AC IN
AC N (Blue)
AC L (Brown)
170±15
Tc 35.7
DC OUT
+DIM
164 fixing center
8
6
AC Side
V+ (Red)
V- (Black)
fixing
Dim+ (Blue) center
Dim- (White)
38
13
32.5
8
160±15
6
3.5
Note: Dim- and V- are internally connected
TOP
14
10
6
13
10
BOTTOM
0.8
DC Side
8
170±15
45.1
8
0.8
160±15
0.8
23
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
L-49