Features LED DRIVER ● ● ● ● ● ● Universal AC Input Constant Voltage / Constant Current Operation CE and UL Certified Class I LED Driver Active Power Factor Correction IP67 Design for Indoor and Outdoor Use Cooling by Free Air Convection LIGHTLINE AC/DC-Converter with 5 Year Warranty Selection Guide Part CV Mode Constant Voltage Current Range (V) (A) CC Mode DC Voltage Range Constant Current (V) (A) Efficiency (230VAC) (typ.) RACD150-12 12 0-11 9-12 11 88% RACD150-24 24 0-6.3 14-24 6.3 90% RACD150-36 36 0-4.2 26-36 4.2 90% RACD150-48 48 0-3.2 34-48 3.2 90% 150 Watt Single Output Specifications Input Voltage Range Input Frequency Range Power Factor THD AC Current Input / Output Isolation Input / Case Isolation Output / Case Isolation Leakage Current Current Tolerance Voltage Tolerance Start-up Time (@ Full Load) Ripple & Noise Full Load, 115VAC Full Load, 230VAC Full Load, 277VAC Full Load, 115VAC 115VAC 230VAC 230VAC 90-305 VAC or 127-430VDC 47-63Hz. >0.98 >0.95 >0.94 8% max. 2A max. 1A max. 3.75kVAC / 1minute 1.8kVAC / 1minute 0.5kVAC / 1minute <0.5mA ±5% -1% to 5% 1.0s 0.8s 200mV max. 150mV max. 115VAC 230VAC / 277VAC 48V Version others (with 20MHz bandwidth & 47μF Elco + 0.1μF MLCC) Over Current Protection 95%-105% rated current Auto-Recovery Short Circuit Protection Hiccup Mode Over Voltage Protection 12V 12.5V typ. Latch Mode 24V 24.5V typ. (Power off to recover) 36V 36.5V typ. 48V 48.5V typ. Over Temperature Protection Tcase 95°C ±10°C Operating Temperature Range without derating -30°C to +50°C (see graph) (free air convection, according to CE/UL) Case Temperature 90°C max. Operation Humidity 20%-90% RH Non-Condensing Storage Temperature -40°C to +80°C Storage Humidity 10%-90% RH Vibration 10-500Hz, 2G, 60 Min. along X, Y and Z IP Rating IP67 Safety Standards UL/cUL LED Lighting Safety (E340696) cUL8750 CE LVD Directive, Safety EN61347-2-13 CB Report: 12CA61289-1 IEC61347-2-13 EMC Standards EMC Compatibility EN55015 FCC, Part 15 Harmonic Current EN61000-3-2 Class C (≥75% load) EN61000-3-3 EMC Immunity EN61000-4-2, 3, 4, 5, 6, 11 Dimension 222*68*39mm Weight 1080g MTBF using MIL-HDBK-217F (25°C) 200 x 10³ hours Design Lifetime 70 x 10³ hours L-64 REV: 0/2015 RoHS 2011/65/EU 6/6 E340696 UL 8750 Certified EN 61347 Certified RACD150 Note: The use of a circuit breaker with C-characteristic is recommended. All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. Refer to Application Notes www.recom-power.com RACD150 Series LIGHTLINE AC/DC-Converter Derating Curves Load Load 100% Ta=25°C 100% 230V 80% 80% 70% 115V 60% 60% 40% 40% 20% 20% -30 -10 0 10 30 50 70 55 90 100 130 180 220 240 300 Input Voltage (VAC) 47-63Hz Ambient Temperature (°C) Typical Characteristics Constant Voltage / Constant Current Curve Output Voltage (%) ~0.5V (max.) Vout (max.) Vout (min.) 0 20 40 60 80 100 120 Output Current (%) Maximum Number of LED drivers per circuit breakers Circuit Breaker 115VAC, 1Ohm 90° phase angle 230VAC, 1Ohm 90° phase angle 277VAC, 1Ohm 90° phase angle RACD150 Condition Circuit Breaker Current Typ 10A 16A 20A 25A C 5 8 9 12 B 4 7 8 9 C 5 13 16 19 B 5 8 9 11 C 9 15 18 21 Package Style and Pinning 222.0 11.4 7.0 300±20 AC/L (Brown) AC/N (Blue) EARTH/PE (Green/Yellow) 10±3 199.2 8.9 34.2 8.9 34.0 99.6 Tc 68.0 300±20 14AWG +V(Red) -V(Black) 35±5 35±5 10±3 39.0 The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 0/2015 L-65