Features LED DRIVER ● ● ● ● ● ● Universal AC Input Constant Voltage / Constant Current Operation CE and ENEC Certified Class I LED Driver Active Power Factor Correction IP67 Design for Indoor and Outdoor Use Cooling by Free Air Convection LIGHTLINE AC/DC-Converter with 5 Year Warranty Selection Guide Part Number CV Mode Constant Voltage Current Range (V) (A) 12 0-11 CC Mode DC Voltage Range Constant Current (V) (A) 9-12 11 NOT RECOMMENDED FOR NEW DESIGNS RACD150-12-ENEC Efficiency (230VAC) (typ.) 88% RACD150-24-ENEC 24 0-6.3 14-24 6.3 90% RACD150-36-ENEC 36 0-4.2 26-36 4.2 90% RACD150-48-ENEC 48 0-3.2 34-48 3.2 90% 150 Watt Single Output Specifications Input Voltage Range Input Frequency Range Power Factor THD AC Current Input / Output Isolation Input / Case Isolation Output / Case Isolation Leakage Current Current Tolerance Voltage Tolerance Start-up Time (@ Full Load) Ripple & Noise Full Load, 115VAC Full Load, 230VAC Full Load, 277VAC Full Load, 115VAC 115VAC 230VAC 230VAC 90-305 VAC or 127-430VDC 47-63Hz. >0.98 >0.95 >0.94 8% max. 2A max. 1A max. 3.75kVAC / 1minute 1.8kVAC / 1minute 0.5kVAC / 1minute <0.5mA ±5% -1% to 5% 1.0s 0.8s 200mV max. 150mV max. 115VAC 230VAC / 277VAC 48V Version others (with 20MHz bandwidth & 47μF Elco + 0.1μF MLCC) Over Current Protection 95%-105% rated current Auto-Recovery Short Circuit Protection Hiccup Mode Over Voltage Protection 12V 12.5V typ. Latch Mode 24V 24.5V typ. (Power off to recover) 36V 36.5V typ. 48V 48.5V typ. Over Temperature Protection Tcase 95°C ±10°C Operating Temperature Range without derating -20°C to +50°C (see graph) (free air convection, according to ENEC) Case Temperature 75°C max. Operation Humidity 20%-90% RH Non-Condensing Storage Temperature -40°C to +80°C Storage Humidity 10%-90% RH Vibration 10-500Hz, 2G, 60 Min. along X, Y and Z IP Rating IP67 Safety Standards RCM (U21457) AS/NZS 61347.1:2002 ENEC General Safety CB Report: IEC 61347-1: 2008 ENEC Safety of AC Control Gear for LED Modules CB Report: IEC 61347-2-13: 2006 EMC Standards EMC Compatibility EN55015 FCC, Part 15 Harmonic Current EN61000-3-2 Class C (≥75% load) EN61000-3-3 EMC Immunity EN61000-4-2, 3, 4, 5, 6, 11 Performance Standard controlgear for LED modules CBReport: IEC 62384:2006 continued on next page L-66 REV: 0/2015 RoHS 2011/65/EU 6/6 EN 61347 Certified EN 62384 Certified RACD150-ENEC Note: The use of a circuit breaker with C-characteristic is recommended. All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. Refer to Application Notes www.recom-power.com RACD150-ENEC Series LIGHTLINE AC/DC-Converter Specifications Dimension Weight MTBF Design Lifetime 222*68*39mm 1080g 200 x 10³ hours 70 x 10³ hours using MIL-HDBK-217F (25°C) Derating Curves Load Load 100% 100% 80% Ta=25°C 80% 70% 60% 60% 40% 40% 20% 20% -20 0 10 30 50 70 90 100 130 180 220 240 300 Input Voltage (VAC) 47-63Hz Ambient Temperature (°C) Typical Characteristics Constant Voltage / Constant Current Curve Output Voltage (%) ~0.5V (max.) Vout (max.) 0 20 40 60 80 100 RACD150 Vout (min.) 120 Output Current (%) Maximum Number of LED drivers per circuit breakers Condition Circuit Breaker Circuit Breaker Current Typ 10A 16A 20A 25A 115VAC, 1Ohm 90° phase angle C 5 8 9 12 230VAC, 1Ohm 90° phase angle B C 4 5 7 13 8 16 9 19 277VAC, 1Ohm 90° phase angle B C 5 9 8 15 9 18 11 21 Package Style and Pinning 222.0 11.4 7.0 300±20 AC/L (Brown) AC/N (Blue) EARTH/PE (Green/Yellow) 10±3 199.2 8.9 34.2 8.9 34.0 99.6 Tc 68.0 300±20 14AWG +V(Red) -V(Black) 35±5 35±5 10±3 39.0 The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 0/2015 L-67