Features Regulated Converters • 30mW max. No Load Power Consumption • High Efficiency up to 80% • Isolated Output 3kVAC / 1 min • SCP, OVP Protection • Wide Operating Temperature Range: -40°C to +85°C • Universal Input 85-305VAC AC/DC Converter RAC03-SE/277 Description The ultra-compact RAC03-SE/277 modules are available with output voltages of 3.3, 5, 12 and 24V, and the input-to-output isolation is 3kVAC/1min. With a standby consumption of 30mW maximum, the mini power supplies are particularly suitable for energy-saving sleep mode and standby applications. Because of its compact design (height <18mm), it is a versatile solution for home automation and other similar applications. Complete with an integrated input filter, the series has enhanced EMI performance and complies with EN55022, class B. The mini power supplies are also protected against short circuit with fully automatic restart after the error has been solved. The converters are EN/UL60950-1 certified and come complete with a 3 year warranty. 3 Watt Single Output 3Y EAR 3 wa rranty Selection Guide Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ. Load (VAC)(VDC) (mA) (%) (µF) RAC03-3.3SE/27785-305 3.3 900 71 22000 RAC03-05SE/27785-305 5 600 76 7500 RAC03-12SE/27785-305 12 250 78 1000 RAC03-24SE/27785-305 24 125 80 200 Specifications (measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 85VAC 120VDC Input Voltage Range Input Current full load, 115VAC full load, 230VAC Inrush Current cold start at 25°C, 115VAC cold start at 25°C, 230VAC 15A 30A 85-305VAC, 47-440Hz 30mW No load Power Consumption 70mA 45mA Input Frequency Range AC Input Hold-up time 115VAC 230VAC 15ms 80ms 100% load at nominal Vin 55kHz Operating Frequency Range 47Hz EN-50155 Certified EN-55024 Certified EN-60950-1 Certified UL-60950-1 Certified 440Hz Efficiency see Selection Guide Minimum Load 2% 200mVp-p Output Ripple and Noise (1) Notes: Note1: E224736 305VAC 430VDC Ripple and Noise is the maximum peak-to-peak voltage value measured at the output with a 20MHz bandwidth, at rated line voltage at full load. And with a 47µF low-ESR electrolytic capacitorin parallel with a 0.1µF ceramic capacitor across output. continued on next page Refer to Applications Notes www.recom-power.com REV.: 0/2015 PA-1 RAC03-SE/277 AC/DC Converter Specifications Series (measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) Efficiency vs. Load RAC03-05SE/277 80 70 Efficiency (%) 60 50 40 30 20 115VAC 230VAC 277VAC 10 0 0 0.1 0.2 0.3 0.4 Output Current (A) REGULATIONS Parameter Condition Value Output Voltage Tolerance (2) ±6% max. Line Voltage Regulation low line to high line, full load Load Voltage Regulation 10% to 100% load Notes: Note2: ±1% typ. / ±1.5% max. ±6% typ. Includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions. PROTECTIONS Parameter Type Value Short Circuit Protection (SCP) continuous, automatic recovery Over Voltage Protection (OVP) Zener Diode clamp 112% - 140% Over Current Limit 120% - 190% Isolation Voltage 3kVAC / 1 Minute Isolation Resistance 1GΩ min. Leakage Current 85-305VAC, 47-440kHz Notes: Note2: Note3: An input fuse must be always used. Recommended fuse: T1A slow blow type An external MOV is required. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 Series L FUSE MOV N PA-2 10µA max. VACin (L) +Vout RAC03-05SE/277 VACin (N) REV.: 0/2015 -Vout www.recom-power.com RAC03-SE/277 AC/DC Converter Specifications Series (measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) ENVIRONMENTAL Parameter Condition Operating Temperature Range Value with derating (see graph) -40°C to +85°C Maximum Case Temperature 105°C Thermal Impedance 10°C / W typ. Humidity non-condensing MTBF (3) MIL-HDBK-217F, 115VAC, +25°C MIL-HDBK-217F, 230VAC, +25°C Notes: Note3: 5% - 95%, RH max. 3503 x 103 hours 1816 x 103 hours MTBF is referring RAC03-3.3SE/277 Derating Graph @ 85-140VAC @ 140-305VAC 100 3.3V and 5V all other models 80 Output Current (%) Output Current (%) 100 60 50 40 20 0 -40 -20 -25 0 10 20 30 40 50 60 70 Ambient Temperature (°C) 75 80 85 90 80 all models 60 50 40 20 0 -40 100 -20 0 10 20 30 40 50 60 70 Ambient Temperature (°C) 75 80 85 90 100 SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Standard EN General Safety SPCLVD1208051 EN-60950-1, 2nd Edition UL General Safety E224736-X1-A24 UL-60950-1, 2nd Edition, 2014 Canada General Safety E224736-X1-A24 CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014 Certificate Type (Environmental) Report / File Number ESD Radiated Immunity Fast Transient Surge Conducted Immunity Voltage dips and variations Voltage flicker EMI Standard Report: 1502CE17 Vibration EN55022, Class B EN55024 MIL-STD-202G Over Voltage Category www.recom-power.com Standard / Criterion EN61000-4-2, Criteria B EN61000-4-3, Criteria A EN61000-4-4, Criteria B EN61000-4-5, Criteria B EN61000-4-6, Criteria A EN61000-4-8, Criteria A EN-61000-3-3 OVC II REV.: 0/2015 PA-3 RAC03-SE/277 AC/DC Converter Specifications Series (measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Case Material Potting Material UL94V-0, black plastic UL94V-0, Silicone Package Dimension (LxWxH) 38.25 x 24.35 x 17.4mm Package Weight 28g typ. Dimension Drawing (mm) 6.1 5.0 17.4 ±0.25 0.75 ±0.25 embossed logo Ø1.0 38.25 5.08 5.08 3 13 17.78 24.35 1 20.32 Bottom View 16 14 Pin Connections Pin # Single 1 VAC in (L) 3 VAC in (N) 13 NC 14 -Vout 16 +Vout NC no connection Tolerance: xx.x= ±0.5mm xx.xx= ±0.35mm Pin width: ±0.05mm PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) Tube 520 x 32 x 27mm Packaging Quantity 12 pcs. Storage Temperature Range -40°C to +85°C Tube Dimension Drawing (mm) 27.4±0.5 8.1±0.5 26.5±0.5 17.25±0.5 2.2±0.5 1±0.2 31.4±0.5 6.5±0.5 The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. PA-4 REV.: 0/2015 www.recom-power.com