RAC03-SER/277 - recom

• 40mW max. No Load Power Consumption
• High Efficiency up to 76%
• Isolated Output 3kVAC / 1 min
• SCP, OVP Protection
• Wide Operating Temperature Range:
-40°C to +85°C
• Universal Input 85-305VAC
Features
Regulated
Converters
AC/DC Converter
RAC03-SER/277
Description
The modules of the RAC03-SER/277 series are regulated AC/DC converters with 3kVAC isolation and a
round, flat shape. This series has been designed to offer low stand-by consumption and an ultra-wide
input voltage range. Uses include a variety of applications in building automation, security systems and
communication systems.
3 Watt
Single
Output
3Y
EAR
3
wa
rranty
Selection Guide
Part
Input
Output
Output
Efficiency
Max. Capacitive
Number
Voltage Range
Voltage
Current
typ.
Load
(VAC)(VDC) (mA) (%)
(µF)
RAC03-3.3SER/27785-305
3.3
900
68
22000
RAC03-05SER/27785-305
5
600
70
7500
RAC03-12SER/27785-305
12
250
74
1000
RAC03-24SER/27785-305
24
125
76
200
Model Numbering
RAC03-__SER/277-_
Output Voltage
Packaging (1)
Notes:
Note1: add suffix “-TRAY” for Tray packaging, without suffix standard cardboard box packaging.
Examples:
e.g. RAC03-05SER/277-TRAY, Single Output, 5Vout and Tray Packaging
E224736
Specifications
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
85VAC
120VDC
Input Voltage Range
Max.
305VAC
430VDC
Input Current
full load, 115VAC
full load, 230VAC
Inrush Current
cold start at 25°C, 115VAC
cold start at 25°C, 230VAC
15A
30A
85-305VAC, 47-440Hz
40mW
No load Power Consumption
70mA
45mA
Input Frequency Range
AC Input
47Hz
Hold-up time
115VAC
18ms
Operating Frequency Range
100% load at nominal Vin
440Hz
55kHz
Efficiency
see Selection Guide
Minimum Load
10%
continued on next page
Refer to Applications Notes
www.recom-power.com
REV.: 0/2015
PA-1
RAC03-SER/277
AC/DC Converter
Specifications
Series
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
3.3Vout
all others
Output Ripple and Noise (1)
Notes:
Note1:
250mVp-p
200mVp-p
Ripple and Noise is the maximum peak-to-peak voltage value measured at the output with a 20MHz bandwidth, at rated line voltage at full load. And with a 47µF low-ESR electrolytic capacitorin parallel with a 0.1µF ceramic capacitor across output.
REGULATIONS
Parameter
Condition
Value
Output Voltage Tolerance (2)
3.3Vout
5Vout
12, 24Vout
±4% typ. / ±8% max.
±3.5% typ. / ±5% max.
±3% typ. / ±4% max.
Line Voltage Regulation
low line to high line, full load
±0.7% typ. / ±1% max.
Load Voltage Regulation
3.3Vout
10% to 100% load
5Vout
10% to 100% load
12, 24Vout 10% to 100% load
±5.5% typ. / ±9% max.
±5% typ. / ±7.5% max.
±4% typ. / ±5.5% max.
Notes:
Note2:
Includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions.
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
Zener Diode clamp
105% - 150%
Over Current Limit
120% - 190%
Isolation Voltage
3kVAC / 1 Minute
Isolation Resistance
1GΩ min.
Leakage Current
85-305VAC, 47-440Hz
Notes:
Note3:
An input fuse must be always used.
L
FUSE
10µA max.
Recommended fuse: T1A slow blow type.
VACin (L)
+Vout
RAC03-05SER/277
N
PA-2
VACin (N)
REV.: 0/2015
-Vout
www.recom-power.com
RAC03-SER/277
AC/DC Converter
Specifications
Series
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
230VAC, with derating (see graph)
-40°C to +85°C
Maximum Case Temperature
105°C
Thermal Impedance
9.5°C / W typ.
Humidity
non-condensing
MTBF (3)
MIL-HDBK-217F, 115VAC, +25°C
MIL-HDBK-217F, 230VAC, +25°C
Notes:
Note3:
5% - 95%, RH max.
3554 x 103 hours
3219 x 103 hours
MTBF is referring RAC03-05SER/277
Derating Graph
@ 85-140VAC
@ 140-305VAC
100
3.3V and 5V
all other models
80
Output Current (%)
Output Current (%)
100
60
50
40
20
0
-40
-20
-25
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
75
80
85
90
80
all models
60
50
40
20
0
-40
100
-20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
75
80
85
90
100
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
EN General Safety
SPCLVD1208051
UL General Safety
E224736-X1-A24
UL-60950-1, 2nd Edition, 2014
Canada General Safety
E224736-X1-A24
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014
Certificate Type (Environmental)
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
PMF
Voltage Dips & Voltage Variations
Condition / Report or File Number
Air ±5kV, Contact ±4kV
3V/m
AC Power Port: ±1kV
AC Power Port: line to line: ±1kV
AC Power Port: 3V/m
1 A/m
Voltage Dips: >95% reduction
30% reduction
Voltage Interruptions: >95% reduction
Voltage
EMI Standard
Report: 1502CE17
Over Voltage Category
www.recom-power.com
Standard
EN-60950-1, 2nd Edition
Standard / Criterion
EN61000-4-2, Criteria B
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria B
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
EN61000-4-11, Criteria B
EN61000-4-11, Criteria C
EN61000-4-11, Criteria C
EN-61000-3-3
EN55022, Class B
EN55024
OVC II
REV.: 0/2015
PA-3
RAC03-SER/277
AC/DC Converter
Specifications
Series
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Case Material
Potting Material
UL94V-0, black plastic
UL94V-0, Epoxy
Package Dimension (LxWxH)
50.3 x 50.3 x 11.0mm
Package Weight
41g typ.
Dimension Drawing (mm)
11.0
31.5
(Blue)
embossed logo
V+
(Red)
Ø1.56
N
(Brown)
Wired Connections
Bottom View
Ø5
4
0.3
2
3
94.0 ±5
Ø2.36
V-
(Black)
L
10 ±2
Ø0.76
Ø0.76
tc
embossed logo
max. 0.1 height
6.0
Top View
Wired Color
1, brown
2, blue
3, red
4, black
Type
Wire Composition Function
UL-1015, AWG22
17/0.16
VAC in (L)
UL-1015, AWG22
17/0.16
VAC in (N)
UL-1430, AWG22
17/0.16
+Vout
UL-1430, AWG22
17/0.16
-Vout
1
Tolerance: xx.x= ±0.5mm
xx.xx=±0.35mm
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Type
Cardboard box
Packaging Quantity
Value
195 x 170 x 140mm
12 pcs
Storage Temperature Range
-40°C to +85°C
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-4
REV.: 0/2015
www.recom-power.com