R-78W - recom

Features
• Efficiency up to 96%, no need for heatsinks!
• Build-in Diode Protection Circuit
• Low Profie (LxWxH= 11.5 x 8.5 x 17.5mm)
• Continuous Short Circuit Protection
• RoHS compliant
• IEC/EN-60950 Certified
Switching
Regulator
DC/DC Converter
R-78W-0.5
Description
The R-78W series offers wired 0.5A switching regulators which are ideally suited to offer a stable
voltage supply without the need for a PCB for applications like high power LED lighting, battery
powered systems, cooling systems, or fans. Due to the high efficiencies of up to 96% there is no
need for a heat sink. The compact modules feature fully protected outputs and draw only 1mA under
no load conditions.
0.5 AMP
SIP3
Single
Output
3Y
EAR
3
wa
rranty
Selection Guide
Part
Number
R-78W3.3-0.5
R-78W5.0-0.5
R-78W9.0-0.5
R-78W12-0.5
Input
Output
Output
Efficiency
Max. Capacitive
Voltage Range
Voltage
Current
@ min. Vin
Load (1)
(VDC)(VDC) (mA) (%)
(µF)
6.5 - 32
3.3
500
88
220
6.5 - 32
5.0
500
93
220
11 - 32
9.0
500
95
220
15 - 32
12.0
500
96
220
Notes:
Note1:
6800µF with <1sec start-up time
Specifications (measured at TA= 25°C, full load, nominal input voltage and after warm-up)
BASIC CHARACTERISTICS
Parameter
Condition
Input Voltage Range
Min.
Typ.
6.5VDC
24VDC
Max.
32VDC
6mA
Output Current (2)
Quiescent Current
0% Load
Switching Frequency
280kHz
500mA
5mA
7mA
330kHz
380kHz
Efficiency
see Selection Guide
0.4W
Internal Power Dissipation
20MHz BW limited
Output Ripple and Noise
Notes:
Note2:
50mVp-p
75mVp-p
Operation under no load will not damage the device, however they may not meet all specifications. A minimum load of 6mA is recommended.
IEC-60950-1 Certified
EN-60950-1 Certified
REGULATIONS
Parameter
Condition
Output Voltage Accuracy
Type
Value
all models
±2% typ. / ±3% max.
Line Voltage Regulation
low line to high line, full load
3.3V, 5V
9V, 12V
±0.2% typ. / ±0.4% max.
±0.1% typ. / ±0.2% max.
Load Voltage Regulation
10% to 100% load
3.3V, 5V
9V, 12V
±0.4% typ. / ±0.6% max.
±0.25% typ. / ±0.4% max.
50% - 100% Load, ΔIo/Δt 25mA/µs
10% - 100% Load, ΔIo/Δt 25mA/µs
all models
±75mV typ.
±100mV max.
Transient Response
Refer to Applications Notes
www.recom-international.com
REV.: 0/2015
PA-1
R-78W-0.5
DC/DC Converter
Series
Specifications (measured at TA= 25°C, full load, nominal input voltage and after warm-up)
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Reverse Current Protection:
+VIN
+VOUT
Controlled IC
-VIN
-VOUT
An internal blocking diode can prevent reverse current flow backwards into the output,
as this can damage the converter when it is powered down.
ENVIRONMENTAL
Parameter
Condition
Value
Operating Temperature Range
with derating
-40°C to +85°C
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +125°C
Temperature Coefficient
-40°C to +85°C ambient
0.015%/°C
Thermal Impedance
surface of case
70°C/W typ.
Humidity
non-condensing
95%, RH max.
9368 x 103 hours
MTBF
Derating Graph
Output Power (%)
100
80
60
40
20
0
-40
-20
0
10
20
30
40
50
60
70
71
Ambient Temperature (°C)
80
90
100
85
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
IEC General Safety
SPCLVD1407030-1
IEC-60950-1, 2nd Edition
EN General Safety
SPCLVD1407030-1
EN-60950-1, 3rd Edition
PA-2
REV.: 0/2015
Standard
www.recom-international.com
R-78W-0.5
DC/DC Converter
Series
Specifications (measured at TA= 25°C, full load, nominal input voltage and after warm-up)
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
Case
Potting
non-conductive black plastic
UL94V-0, Epoxy
Dimensions (LxWxH)
17.5 x 11.5 x 8.5mm
Weight
4.8g typ.
Packaging Dimensions (LxWxH)
Cardboard Box
140 x 130 x 65mm
Packaging Quantity (3)
Cardboard Box
25pcs.
Notes:
Note3:
5 bubble packs each containing 5pcs in a cardboard box.
Mechanical Dimensions (mm)
11.5
17.5
R-78W
-xx0.5
10.0 ±2
105.0 ±5
xxxx
0.51
Bottom View
1
2
3
Wired Connections
Front
Wired Color
Type
1, red
UL-1430, AWG#22
2, black
UL-1430, AWG#22
3, brown
UL-1430, AWG#22
Tolerance: ±0.5mm
Single
+Vin
GND
+Vout
8.5
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-international.com
REV.: 0/2015
PA-3