RAC03-SE/277/W - recom

Features
Regulated
Converters
• 30mW max. No Load Power Consumption
• High Efficiency up to 80%
• Isolated Output 3kVAC / 1 min
• SCP, OVP Protection
• Wide Operating Temperature Range:
-40°C to +85°C
• Universal Input 85-305VAC
AC/DC Converter
RAC03-SE/277/W
Description
The ultra-compact wired RAC03-SE/277/W modules are available with output voltages of
3.3, 5, 12 and 24V, and the input-to-output isolation is 3kVAC/1min. With a standby
consumption of 30mW typical, the mini power supplies are particularly suitable for energy-saving
sleep mode and standby applications. Because of its compact design (height <18mm), it is a
versatile solution for home automation and other similar applications. Complete with an integrated
input filter, the series has enhanced EMI performance and complies with EN55022, class B. The mini
power supplies are also protected against short circuit with fully automatic restart after the error has
been solved. The converters are EN/UL60950-1 certified and come complete with a 3 year warranty.
3 Watt
Single
Output
3Y
EAR
3
wa
rranty
Selection Guide
Part
Input
Output
Output
Efficiency
Max. Capacitive
Number
Voltage Range
Voltage
Current
typ.
Load
(VAC)(VDC) (mA) (%)
(µF)
RAC03-3.3SE/277/W85-305
3.3
900
71
22000
RAC03-05SE/277/W85-305
5
600
76
7500
RAC03-12SE/277/W85-305
12
250
78
1000
RAC03-24SE/277/W85-305
24
125
80
200
Specifications
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
85VAC
120VDC
Input Voltage Range
305VAC
430VDC
Input Current
full load, 115VAC
full load, 230VAC
Inrush Current
cold start at 25°C, 115VAC
cold start at 25°C, 230VAC
15A
30A
85-305VAC, 47-440Hz
30mW
No load Power Consumption
70mA
45mA
Input Frequency Range
AC Input
Hold-up time
115VAC
230VAC
15ms
80ms
100% load at nominal Vin
55kHz
Operating Frequency Range
47Hz
EN-50155 Certified
EN-55024 Certified
EN-60950-1 Certified
UL-60950-1 Certified
440Hz
Efficiency
see Selection Guide
Minimum Load
2%
Output Ripple and Noise (1)
Notes:
Note1:
E224736
200mVp-p
Ripple and Noise is the maximum peak-to-peak voltage value measured at the output with a 20MHz bandwidth, at rated line voltage at full load. And with a 47µF low-ESR electrolytic capacitorin parallel with a 0.1µF ceramic capacitor across output.
Refer to Applications Notes
www.recom-power.com
REV.: 0/2015
PA-1
RAC03-SE/277/W
AC/DC Converter
Specifications
Series
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
Efficiency vs. Load
RAC03-05SE/277/W
80
70
Efficiency (%)
60
50
40
30
20
115VAC
230VAC
277VAC
10
0
0
0.1
0.2
0.3
0.4
Output Current (A)
REGULATIONS
Parameter
Condition
Value
Output Voltage Tolerance (2)
±6% max.
Line Voltage Regulation
low line to high line, full load
Load Voltage Regulation
10% to 100% load
Notes:
Note2:
±1% typ. / ±1.5% max.
±6% typ.
Includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions.
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
Zener Diode clamp
112% - 140%
Over Current Limit
120% - 190%
Isolation Voltage
3kVAC / 1 Minute
Isolation Resistance
1GΩ min.
Leakage Current
85-305VAC, 47-440Hz
Notes:
Note2:
An input fuse must be always used.
L
FUSE
10µA max.
Recommended fuse: T1A slow blow type.
VACin (L)
+Vout
RAC03-05SE/277/W
N
PA-2
VACin (N)
REV.: 0/2015
-Vout
www.recom-power.com
RAC03-SE/277/W
AC/DC Converter
Specifications
Series
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
230VAC, with derating (see graph)
-40°C to +85°C
Maximum Case Temperature
105°C
Thermal Impedance
10°C / W typ.
Humidity
non-condensing
MTBF (3)
MIL-HDBK-217F, 115VAC, +25°C
MIL-HDBK-217F, 230VAC, +25°C
Notes:
Note3:
5% to 95%, RH max.
3503 x 103 hours
1816 x 103 hours
MTBF is referring RAC03-3.3SE/277/W
Derating Graph
@ 85-140VAC
@ 140-305VAC
100
3.3V and 5V
all other models
80
Output Current (%)
Output Current (%)
100
60
50
40
20
0
-40
-20
-25
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
75
80
85
90
80
all models
60
50
40
20
0
-40
100
-20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
75
80
85
90
100
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
EN General Safety
SPCLVD1208051
UL General Safety
E224736-X1-A24
UL-60950-1, 2nd Edition, 2014
Canada General Safety
E224736-X1-A24
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014
Certificate Type (Environmental)
Report / File Number
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Voltage dips and variations
Voltage flicker
EMI Standard
Standard / Criterion
EN61000-4-2, Criteria B
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria B
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
EN-61000-3-3
Report: 1502CE17
Over Voltage Category
www.recom-power.com
Standard
EN-60950-1, 2nd Edition
EN55022, Class B
EN55024
OVC II
REV.: 0/2015
PA-3
RAC03-SE/277/W
AC/DC Converter
Specifications
Series
(measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Case Material
Potting Material
UL94V-0, black plastic
UL94V-0, Epoxy
Package Dimension (LxWxH)
38.25 x 24.35 x 17.4mm
Package Weight
29g typ.
Dimension Drawing (mm)
0.75 ±0.25
17.4 ±0.25
embossed logo
10 ±3
85 ±5
5.0
Wired Connections
2
24.35
1
Ø1.56
Ø0.76
Ø2.36
Ø0.76
38.25
Bottom View
3
38.25
4
Wired Color
1, brown
2, blue
3, red
4, black
Type
Wire Composition Function
UL-1015, AWG22
17/0.16
VAC in (L)
UL-1015, AWG22
17/0.16
VAC in (N)
UL-1430, AWG22
17/0.16
+Vout
UL-1430, AWG22
17/0.16
-Vout
Tolerance: xx.x= ±0.5mm
xx.xx=±0.35mm
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Type
Cardboard Box
Packaging Quantity
Value
520 x 195 x 68mm
30 pcs.
Storage Temperature Range
-40°C to +85°C
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-4
REV.: 0/2015
www.recom-power.com