VECTRON TFS434D

Filename: tfs 434d.doc
Version 1.2
VI TELEFILTER
24.04.2006
Filter specification
TFS 434D
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
240 Ω || -2,5 pF
240 Ω || -2,5 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 434,42 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 434D is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
ae = amin
Insertion loss
(reference level)
1,8
Nominal frequency
fN
-
Centre frequency 3dB
fC
434,46
PB
-
Passband
-
0,16
0,18
0,22
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
+
+
+
+
+
423,92
19,92
10,42
2,20
1,80
1,00
8,08
66,08
266,08
371,08
dB
max.
3,0
434,42
MHz
dB
MHz
fN
±
0,16
MHz
arel
Relative attenuation
fN
fN
fN
tolerance / limit
MHz … fN
MHz … fN
MHz … fN
+
+
+
0,16
0,18
0,22
MHz
MHz
MHz
0,7
1,2
3,1
dB
dB
dB
max.
max.
max.
2
3
6
dB
dB
dB
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
+
+
+
+
+
19,92
10,42
2,20
1,80
0,82
8,08
66,08
266,08
371,08
566,08
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
55,6
53,6
49,5
54,7
17,8
35,4
43,2
62,3
51,6
65,5
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
52
48
29
26
15
18
40
50
45
60
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
-
max.
10
dBm
-
max.
6
…
…
…
…
…
…
…
…
…
…
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
Input power level
Permissible DV voltage
VDC
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
-
- 40 °C ... + 95°C
-
- 45 °C ... + 120°C
-0,03
ppm/K
V
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 434d.doc
Version 1.2
VI TELEFILTER
24.04.2006
Filter specification
TFS 434D
2/5
0
0
-10
-0.5
-20
-1
-30
-1.5
-40
magnitude in dB
magnitude in dB
Filter characteristic
-50
-60
-2
-2.5
-3
-70
-3.5
-80
-4
-90
-4.5
-100
300
400
500
600
700
frequency in MHz
800
900
-5
1000
434.1
434.2
434.3
434.4
434.5
frequency in MHz
434.6
434.7
434.8
Construction and pin connection
(All dimensions in mm)
7
434D
● U17
1
SQ 3,81 +0,2/-0,1
5
3
1
2
3
4
5
6
7
8
Input RF Return
Input
Ground
Ground
Output
Output RF Return
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
7
5
0,1
12
0%
0,6
%
d
3
1,78
2,54
1
1,2 Max.
Date code
1,78
50 Ω Test circuit
L1
2
1
5
SAW
L2
6
3, 4, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 434d.doc
Version 1.2
VI TELEFILTER
24.04.2006
Filter specification
TFS 434D
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 434d.doc
Version 1.2
VI TELEFILTER
24.04.2006
Filter specification
TFS 434D
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 434d.doc
VI TELEFILTER
Version 1.2
Filter specification
24.04.2006
TFS 434D
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
24.03.2006
1.1
- Change relative attenuation
Strehl
28.03.2006
1.2
- Add typical values, add filter characteristic
- Generation of filter specification
Channaa
24.04.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.