Filename: tfs 456p.doc Version 1.4 VI TELEFILTER 08.12.2006 Filter specification TFS 456P 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 540 Ω || -3,6 pF 680 Ω || -3,8 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 456P is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 456,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae 8,0 Nominal frequency fN - Centre frequency fC 456,0 PB Passband Pass band ripple Bandwidth BW 1 dB Relative attenuation arel fN fN fN ± ± ± 1,75 2 20 MHz … fN MHz … fN MHz … fN ± ± ± 2 20 192 MHz MHz MHz Group delay ripple within fN ± 0,6 MHz Group delay ripple within PB Return loss within PB Input power level Operating temperature range OTR dB max. Frequency inversion temperature TCf ** 10,0 456,0 MHz dB MHz - - fN ± 0,79 MHz 0,3 dB max. 1,0 dB 1,81 MHz min. 1,58 MHz 39 45 54 dB dB dB min. min. min. 35 40 50 dB dB dB 120 320 ns ns max. max. 250 500 ns ns 14 dB min. 10 dB - max. 15 dBm - - 40 °C ... + 85°C - Storage temperature range Temperature coefficient of frequency tolerance / limit - 45 °C ... + 85°C 16 °C - 0,04 ppm/K 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456p.doc Version 1.4 VI TELEFILTER 08.12.2006 Filter specification TFS 456P 2/5 0 4.38 -1 3.96 -16 -2 3.54 -24 -3 3.12 -32 -4 2.7 -5 2.28 -6 1.86 -56 -7 1.44 -64 -8 1.02 -72 -9 0.6 -40 -48 -80 406 416 426 436 446 456 466 frequency in MHz 476 486 496 -10 455 506 455.2 455.4 455.6 455.8 456 456.2 frequency in MHz 456.4 456.6 456.8 delay in µs 0 -8 magnitude in dB magnitude in dB Filter characteristic 0.18 457 Construction and pin connection (All dimensions in mm) S 456P ● U49 Date code 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output Output RF Return Ground Ground Ground Input Input RF Return Date code: U V W ... Year + week 2006 2007 2008 50 Ω Test circuit 9 L1 10 4 SAW L2 L3 5 L4 1, 2, 3, 6, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456p.doc Version 1.4 VI TELEFILTER 08.12.2006 Filter specification TFS 456P 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 P1 Date Code Do P2 W G Ct Bo F G E t Po Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456p.doc Version 1.4 VI TELEFILTER 08.12.2006 Filter specification TFS 456P 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456p.doc VI TELEFILTER Version 1.4 Filter specification 08.12.2006 TFS 456P 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 18.11.2005 1.1 - Correct data, pin connection and stability characteristics Strehl 13.12.2005 1.2 - Change pin connection Strehl 21.12.2005 1.3 - terminating impedance, typical values, filter characteristic and matching configuration added - pass band frequency range changed Pfeiffer 29.03.2006 1.4 - Add input power level Strehl 08.12.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.