VECTRON TFS140AP

Filename: tfs 140ap.doc
Version 1.3
VI TELEFILTER
15.11.2006
Filter specification
TFS 140AP
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
102 Ω || -38 pF
99 Ω || -36 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 140,0 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 140AP is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the
20 dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
Nominal frequency
fN
-
Centre frequency
fC
140
PB
Passband
dB
dB
8,8
130,0
30,0
max.
10,0
140,0
MHz
dB
MHz
-
MHz
fN
dB
24,8
45,9
±
8,8
MHz
max.
1
dB
MHz
MHz
min.
max.
22,0
60,0
MHz
MHz
0,3
2
47
42
dB
dB
dB
dB
max.
max.
min.
min.
1
3
40
40
dB
dB
dB
dB
35
ns
max.
160
ns
max.
0
arel
Relative attenuation
±
+
dB
BW
Bandwidth
fN
fN
fN
fN
22,9
0,3
Pass band ripple
3
40
7,6
tolerance / limit
… fN
MHz ... fN
MHz ... fN
MHz ... fN
Group delay ripple within PB
±
±
+
8,8
11,0
30,0
370,0
MHz
MHz
MHz
MHz
p-p
-
Input power level
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
-
- 5 °C ... + 80°C
-
- 55 °C ... + 80°C
-95
dBm
ppm/K
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ap.doc
Version 1.3
VI TELEFILTER
15.11.2006
Filter specification
TFS 140AP
2/5
0
1.45
-0.6
1.33
-14
-1.2
1.21
-21
-1.8
1.09
-28
-2.4
0.97
-3
0.85
-3.6
0.73
-49
-4.2
0.61
-56
-4.8
0.49
-63
-5.4
0.37
-35
-42
-70
40
60
80
100
120
140
160
frequency in MHz
180
200
220
-6
126
240
128.8
131.6
134.4
137.2
140
142.8
frequency in MHz
145.6
148.4
151.2
delay in µs
0
-7
magnitude in dB
magnitude in dB
Filter characteristic
0.25
154
Construction and pin connection
(All dimensions in mm)
TFS 140AP
●
U46
6,8Max.
13,6Max.
1
2,54 ±0,15
2,54 ±0,15
1 2 3 4
2,0Max.
1,5
Date code
12
5
11
6
10 9 8 7
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Ground
Input
Input RF Return
Date code:
U
V
W
...
Year + week
2006
2007
2008
0,1
0,8
50 Ohm Test circuit
11
L1
12
5
SAW
L2
L3
6
L4
1,2,3,4,7,8,9,10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ap.doc
Version 1.3
VI TELEFILTER
15.11.2006
Filter specification
TFS 140AP
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 24,00 +0,30/-0,10
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50
Ao
: 7,10 ± 0,10
Bo
: 13,90 ± 0,10
Ct
: 21,5 ± 0,1
Date Code
Do
P2
W
G
Ct
Bo
F
G
E
t
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
: 60
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ap.doc
Version 1.3
VI TELEFILTER
15.11.2006
Filter specification
TFS 140AP
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ap.doc
VI TELEFILTER
Version 1.3
Filter specification
15.11.2006
TFS 140AP
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
17.05.2006
1.1
- Correct bandwidth from 30dB to 40dB
Strehl
23.05.2006
1.2
- Change construction
Strehl
24.07.2006
1.3
- Created filter specification
- Added terminating impedances
- Added typical values
- Added temperature coefficient of frequency
- Added filter characteristic
- Changed construction
- Added test circuit
- Changed packing
Chilla
15.11.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.