VI TELEFILTER Filter specification TFS 248F 1/5

Filename: tfs 248f.doc
Version 3.1
VI TELEFILTER
01.04.2008
Filter specification
TFS 248F
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
200
Ω
Ω
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 248F is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 248,6 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
2,95
Nominal frequency
fN
-
PB
Passband
Pass band ripple
dB
238,6
fN
3,5
±
dB
248,6
MHz
352
kHz
0,15
dB
max.
0,5
dB
6,44
MHz
min.
5,0
MHz
50
55
58
56
55
55
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
45
45
45
45
45
45
dB
dB
dB
dB
dB
dB
55
ns
max.
300,0
ns
max.
20,0
arel
Relative attenuation
fN -
max.
BW
Bandwidth
3
dB
tolerance / limit
MHz ...
@
@
@
@
@
fN
fN
fN
fN
fN
fN
+
+
+
+
+
29,2
22,8
52,0
74,8
104,0
126,8
MHz
MHz
MHz
MHz
MHz
MHz
Group delay ripple within PB
-
Input power level
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf *
-
- 20 °C ... + 80 °C
-
- 40 °C ... + 85 °C
-33,5
ppm/K
dBm
-
*) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 248f.doc
Version 3.1
VI TELEFILTER
01.04.2008
Filter specification
TFS 248F
2/5
0
2.3
-1
2.06
-20
-2
1.82
-30
-3
1.58
-40
-4
1.34
-5
1.1
-6
0.86
-70
-7
0.62
-80
-8
0.38
-90
-9
0.14
-50
-60
-100
198.6
208.6
218.6
228.6
238.6
248.6
258.6
frequency in MHz
268.6
278.6
288.6
-10
244.6
298.6
245.4
246.2
247
247.8
248.6
249.4
frequency in MHz
250.2
251
251.8
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
-0.1
252.6
Construction and pin connection
(All dimensions in mm)
S 248F
● W14
Date code
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Output
Output
Ground
Ground
Ground
Input RF Return
Input
Date code:
W
X
A
...
Year + week
2008
2009
2010
50 / 200 Ω Test circuit
10
4
SAW
5
1, 2, 3, 6, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 248f.doc
Version 3.1
VI TELEFILTER
01.04.2008
Filter specification
TFS 248F
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 +0,3/-0,1
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,75
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,40 ± 0,1
Bo
: 7,60 ± 0,1
Ct
: 13,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 248f.doc
Version 3.1
VI TELEFILTER
01.04.2008
Filter specification
TFS 248F
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max.
260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 248f.doc
VI TELEFILTER
Version 3.1
Filter specification
01.04.2008
TFS 248F
5/5
History
Version
Reason of Changes
Name
Date
1.0
- generate according to customer specification
Dr. Sabah
25.09.01
2.0
- change of package and stop band rejection
Dr. Sabah
13.09.02
3.0
- Filter Specification; add of terminating impedance and typ. values
Dr. Sabah
15.11.02
3.1
- change PB and stability characteristic
- add filter characteristic
Strehl
01.04.2008
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.