Highly compact signal conditioners MINI Analog RZ_Bro_IF_MiniAnalog_DE.indd 1 30.10.12 13:42 Highly compact signal conditioners – MINI Analog creates space in your control cabinet Maximum signal quality with minimal space requirements – MINI Analog signal conditioners isolate, convert, filter, and amplify your analog signals – with a design width of just 6.2 mm. Time-saving system cabling Plug & Play – for eight channels on the signal conditioner and controller side Fault monitoring and power bridging The DIN rail connector simplifies supply and enables convenient group error monitoring. Significant space savings Worldwide use, thanks to the international approval package 2 Space savings of up to 65% compared to other signal conditioners on the market thanks to the 6.2 mm design width PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 2 30.10.12 13:42 Convenient configuration and monitoring The configurable MINI Analog modules are easy to set with DIP switches – without the need for any software. Alternatively, Phoenix Contact can make the settings based on your individual ordering information. For enhanced functionality and monitoring, you can also configure the modules with the robust S-Port interface conveniently using a free-of-charge software interface. Here you can choose between three solutions: 1. Standalone ANALOG-CONF software 2. FDT/DTM software package 3. Standalone DTMs, allowing you to use your existing FDT frame application Product overview Signal conditioners Analog IN/ Analog OUT 2-wire • Universal and standard 3-way isolators • 3-way repeater power supplies • 4-way signal duplicators • 2-way passive isolators • 2-way loop-powered isolators 3-wire 4-wire Page 8 Temperature transducers Temperature • Universal and standard measuring transducers for thermocouples • Universal and standard measuring transducers for resistance thermometers • Loop-powered PT100 measuring transducers Page 10 Frequency transducers Frequency • Frequency transducers • Analog frequency transducers Page 11 Potentiometer measuring transducers Potentiometers • with automatic potentiometer detection Page 11 Threshold value switches Limit values + + I • Threshold value switches with PDT relay U - - NAMUR signal conditioners Digital IN - + Accessories Page 11 - - + + • NAMUR signal conditioners with relay output Page 11 • Supply components • Fault monitoring module • System cabling • Multiplexer • Labeling material Page 14 PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 3 3 30.10.12 13:43 Highly compact MINI Analog signal conditioners – your advantages The product range provides maximum efficiency in terms of • Space requirements • Costs • Power consumption • Planning and installation • Configuration Maximum signal quality with minimal space requirements High energy efficiency and long service life Module width 6.2 mm 62 mm Power consumption 65% space saving 175 mm Module width 17.5 mm With the narrow MINI Analog modules, you can save up to 65% space compared to other signal conditioners on the market that have a design width of 12.5 mm to 22.5 mm. 4 100% Other signal conditioners on the market 25% MINI Analog t With MINI Analog, the energy-efficient design of your automation processes starts in the control cabinet: The modules have low power consumption, thanks to their innovative circuit design. As a result the modules heat up less and therefore have a longer life. You can therefore achieve a high level of operational reliability across the entire operating temperature range, even when arranged in series. PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 4 30.10.12 13:43 Power supply – flexible and easy MINI Analog signal conditioners offer a system solution for supplying devices: use the DIN rail connector to bridge the DC supply voltage. This simplifies wiring, system expansion or module replacement, even during operation. The DIN rail connector gives you three device supply options: 1. Direct DC supply at any MINI Analog module: • For up to 16 MINI Analog modules • No additional accessories required other than the DIN rail connector 2. Via a power module of the same shape: • For up to 80 MINI Analog modules • Also allows redundant supply and supply monitoring 3. Via the system power supply unit with wide range input 85…264 V AC: • If no DC supply is available • For up to 60 MINI Analog modules 2 Power IN 2 Power IN 1 Power IN MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI Power module MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MIN M MINI M MCRR-R RTD-U -UI UII MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI 3 MINI MCR-RTD-UI Power supply unit Power IN Convenient error evaluation with fault monitoring It is also possible to detect and signal the failure of a supply voltage at the power terminal block. The modularity is characterized by the ability to freely adjust the error evaluation, both on the device side and in the evaluation module. Error message contact Power IN Power module MINI MCR-SL-PTB-FM Fault monitoring module MINI MCR-SL-FM-RC Fault monitoring is a modular solution for convenient error evaluation in multi-channel applications. Depending on the module type, the following errors can be indicated by means of a group error message: • Measuring range overshot • Measuring range undershot • Open circuit • Short circuit • Module error Group error message For up to 80 devices F85 2-6 F85 2-6 F85 2-6 F85 2-6 Supply voltage monitoring PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 5 5 30.10.12 13:44 Reduction in analog inputs at controllers 1x Analo The MINI Analog multiplexer enables you to reduce up to eight analog signals to a single 4...20 mA signal. g 8x Analo Simply ingenious An easy DIP switch configuration allows you to choose between 2-, 4-, 6- or 8-channel operation. The channels are switched over in 1- or 2-second cycles. g The channel currently switched is detected via three digital outputs using a bit pattern. Straightforward configuration via DIP switch Temperature measurement in wind power plants A wide range of temperatures are measured in wind power plants. As a general rule, at least 6 measuring points are monitored. The MINI Analog multiplexer reduces these signals to just one and thereby lowers the number of analog inputs at the central acquisition point. MINI MCR-SL-UI-UI MCR-SL-PT 100 MINI MCR-SL-UI-UI MCR-SL-PT 100 8 7 6 5 1 2 3 4 8 7 6 5 1 2 3 4 MINI MCR-SL-UI-UI MCR-SL-PT 100 8 7 6 5 1 2 3 4 MINI MCR-SL-UI-UI MCR-SL-PT 100 8 7 6 5 1 2 3 4 MINI MCR-SL-UI-UI MCR-SL-PT 100 8 7 6 5 1 2 3 4 MINI MCR-SL-UI-UI MCR-SL-PT 100 8x Analog IN 6 8 7 6 5 1 2 3 4 MINI MCR-SL-UI-UI MCR-SL-PT 100 1x Analog IN SF 4…20 mA 8 7 6 5 MINI MCR-SL-UI-UI MCR-SL-PT 100 Power 8 7 6 5 1 2 3 4 8 x PT100 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 1 2 3 4 At the same time, the amount of cabling can be significantly reduced, for example, directly at the generator. The signal is then directly converted on-site to a 4...20 mA signal, electrically isolated and amplified. AO DO DO DO MINI MCR-SL-MUX RUN-P RUN Controller BATF 0 0 0 DC5V 1 1 1 FRCE 2 2 2 RUN 3 3 3 STOP 4 4 4 5 5 5 6 6 6 7 7 7 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 STOP MRES 3 x Digital IN PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 6 30.10.12 13:44 Isolating, converting, filtering, and amplifying – the functions at a glance Electrical isolation The most important task of a signal conditioner is the electrical isolation of signals. MINI Analog offers consistent isolation of input, output, and supply. As such, ground current loops can be prevented in the event of potential differences, which would otherwise lead to a distortion of the measured process values. PLC RUN FAIL MRESET STP 11 RUN/PROG 13 ETH 15 12 17 14 19 16 18 I11 Q1 I10 Q3 I12 E US Q2 UL Q4 UM 10/100 BASE-T LNK ACT 100 Ig ≠ I1 Sensor INLINE CONTROL ILC 350 ETH Ord.No.: 2737203 RESET IL PRG RDY/RUN BSA FAIL PF I2 Ground current loop Potential 2 Potential 1 PLC RUN FAIL MRESET STP 11 RUN/PROG 13 ETH Ig = I1 Sensor 15 12 17 14 19 16 I11 18 Q1 I10 Q3 I12 E US Q2 UL Q4 UM 10/100 BASE-T LNK ACT 100 INLINE CONTROL ILC 350 ETH Ord.No.: 2737203 RESET IL PRG RDY/RUN BSA FAIL PF I2 = 0 No ground current loop Potential 1 Potential 1 Converting signals An advantage of signal conversion is the conversion of sensor signals into a signal that can be read by the controller, such as PT100 in 4...20 mA. In addition, failure-prone signals such as 0 - 10 V, for example, can be converted into non-prone current signals. Amplifying signals Signals always need to be amplified in the event that cables are long or if high loads are to be driven. It is here where the signal conditioners of the MINI Analog range provide a high output power at a low input power. STP 11 13 15 12 19 16 I11 18 Q1 I10 Q3 I12 E US Q2 UL Q4 UM 0 – 10 V 4 – 20 mA INLINE CONTROL ILC 350 ETH Ord.No.: 2737203 RESET IL PRG Can only drive loads of up to 300 Ω Can amplify loads of up to 500 Ω RDY/RUN BSA FAIL PF MRESET STP PLC RUN FAIL 11 RUN/PROG 13 ETH 15 12 14 17 19 16 18 E Q1 I11 I10 I12 Q3 Q2 Q4 US UL UM 10/100 BASE-T Sensor 4 – 20 mA LNK ACT 100 4 – 20 mA INLINE CONTROL ILC 350 ETH Ord.No.: 2737203 RESET PRG U IL RDY/RUN BSA FAIL PF U t t MRESET STP PLC RUN FAIL 11 RUN/PROG 13 ETH Sensor 17 14 10/100 BASE-T Sensor Filtering signals In industrial environments, interference often occurs as a result of high-frequency signals. The input filters of the MINI Analog signal conditioners therefore reliably filter out such interfering signals. PLC RUN FAIL MRESET RUN/PROG ETH LNK ACT 100 15 12 14 17 19 16 18 I11 Q1 I10 I12 Q3 E Q2 Q4 US UL UM 10/100 BASE-T 0 – 10 V 0 – 10 V LNK ACT 100 INLINE CONTROL ILC 350 ETH Ord.No.: 2737203 RESET PRG IL RDY/RUN BSA FAIL PF PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 7 7 30.10.12 13:44 MINI Analog – the complete range Analog IN/Analog OUT IN U,I U,I OUT POWER Analog IN/Analog OUT IN T-Connector Compatible 3-way signal conditioner, Configurable U U,I Analog IN/Analog OUT IN OUT U T-Connector Compatible POWER 3-way signal conditioner, Configurable U,I OUT T-Connector Compatible POWER 3-way signal conditioner, Configurable IN 0 … 20 mA/4 … 20 mA 0 … 5 V/1 … 5 V 0 … 10 V/2 … 10 V Can be set via DIP switch Unipolar/bipolar: 0 … 50 mV/0 … 60 mV/0 … 75 mV/0 … 80 mV/ 0 … 100 mV/0 … 120 mV/0 … 150 mV/ 0 … 200 mV/0 … 240 mV/0 … 300 mV/ 0 … 500 mV/0 … 600 mV/0 … 750 mV/ 0 … 800 mV/0 … 1 V/0 … 1.2 V/0 … 1.5 V/ 0 … 2 V/0 … 2.4 V/0 … 3 V Can be set via DIP switch 0 … 24 V/0 … 30 V Can be set via DIP switch OUT 0 … 20 mA/4 … 20 mA 0 … 5 V/1 … 5 V 0 … 10 V/2 … 10 V Can be set via DIP switch 0 ... 20 mA/4 ... 20 mA 0 ... 5 V/1 ... 5 V 0 ... 10 V/2 ... 10 V -5 ... 5 V/-10 ... 10 V Can be set via DIP switch 0 ... 20 mA/4 ... 20 mA 0 ... 5 V/1 ... 5 V 0 ... 10 V/2 ... 10 V Can be set via DIP switch Screw connection MINI MCR-SL-UI-UI-NC 2864150 MINI MCR-SL-SHUNT-UI-NC 2810780 MINI MCR-SL-U-UI-NC 2865007 Spring-cage connection MINI MCR-SL-UI-UI-SP-NC 2864163 MINI MCR-SL-SHUNT-UI-SP-NC 2810793 MINI MCR-SL-U-UI-SP-NC 2810078 Analog IN/Analog OUT Analog IN/Analog OUT Analog IN/Analog OUT IN U,I U,I OUT POWER 3-way signal conditioner, With fixed signal combinations IN T-Connector Compatible U I OUT T-Connector Compatible POWER 3-way signal conditioner, With fixed signal combinations IN I U OUT POWER T-Connector Compatible 3-way signal conditioner, With fixed signal combinations IN 1) 0 … 20 mA/4 … 20 mA 2) 0 … 10 V/-10 … 10 V 0 … 10 V 1) 0 … 20 mA 2) 4 … 20 mA OUT 1) 0 … 20 mA/4 … 20 mA 2) 0 … 10 V/-10 … 10 V 1) 0 … 20 mA 2) 4 … 20 mA 0 … 10 V Screw connection 1) MINI MCR-SL-I-I 2864406 2) MINI MCR-SL-U-U 2864684 1) MINI MCR-SL-U-I-0 2813512 2) MINI MCR-SL-U-I-4 2813525 1) MINI MCR-SL-I-U-0 2813541 2) MINI MCR-SL-I-U-4 2813538 Spring-cage connection 1) MINI MCR-SL-I-I-SP 2864723 2) MINI MCR-SL-U-U-SP 2864697 1) MINI MCR-SL-U-I-0-SP 2813570 2) MINI MCR-SL-U-I-4-SP 2813583 1) MINI MCR-SL-I-U-0-SP 2813554 2) MINI MCR-SL-I-U-4-SP 2813567 8 PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 8 T-Connector Compatible The module can be snapped onto the DIN rail connector. 30.10.12 13:44 MINI Analog – the complete range Analog IN/Analog OUT Analog IN/Analog OUT Analog IN/Analog OUT OUT1 I IN U,I I OUT2 POWER I IN T-Connector Compatible I OUT POWER T-Connector Compatible IN I I OUT POWER POWER Signal duplicator, Configurable Repeater power supply Repeater power supply transparent POWER T-Connector Compatible IN 0 … 20 mA/4 … 20 mA 0 … 10 V/1 … 5 V Can be set via DIP switch Isolator operation: 0 … 20 mA/4 … 20 mA Repeater power supply operation: 4 … 20 mA Isolator operation: 0 … 20 mA/4 … 20 mA Repeater power supply operation: 4 … 20 mA OUT 2 x 0 … 20 mA/2 x 4 … 20 mA Can be set via DIP switch 0 … 20 mA/4 … 20 mA 0 … 20 mA/4 … 20 mA Screw connection MINI MCR-SL-UI-2I-NC 2864176 MINI MCR-SL-RPS-I-I 2864422 MINI MCR-SL-RPSS-I-I 2864079 Spring-cage connection MINI MCR-SL-UI-2I-SP-NC 2864189 MINI MCR-SL-RPS-I-I-SP 2864752 MINI MCR-SL-RPSS-I-I-SP 2810230 Analog IN/Analog OUT Analog IN/Analog OUT U, I IN I I OUT T-Connector Compatible Passive isolator Supplied by an input loop IN POWER IN 1) 0 … 20 mA/4 … 20 mA 2) 2 x 0 … 20 mA/2 x 4 … 20 mA OUT I Loop-powered isolator Supplied by an output loop 0 … 2 mA to 0 … 40 mA (16 ranges) Unipolar and bipolar: 0 … 50 mV to 0 … 30 V (58 ranges) Can be set via DIP switch OUT 1) 0 … 20 mA/4 … 20 mA 2) 2 x 0 … 20 mA/2 x 4 … 20 mA 4 … 20 mA Screw connection 1) MINI MCR-SL-1CP-I-I 2864419 2) MINI MCR-SL-2CP-I-I 2864655 MINI MCR-SL-UI-I-LP-NC 2902829 Spring-cage connection 1) MINI MCR-SL-1CP-I-I-SP 2864749 2) MINI MCR-SL-2CP-I-I-SP 2864781 MINI MCR-SL-UI-I-LP-SP-NC 2902830 T-Connector Compatible The module can be snapped onto the DIN rail connector. RZ_Bro_IF_MiniAnalog_DE.indd 9 Order configuration You can order your desired device configuration easily and flexibly: • Using order keys from the catalog or • In the user-guided e-shop www.phoenixcontact.net/catalog PHOENIX CONTACT 9 30.10.12 13:44 MINI Analog – the complete range Temperature U,I IN Temperature OUT T-Connector Compatible FM POWER Universal measuring transducer for resistance thermometers IN PT100 U,I Temperature OUT POWER T-Connector Compatible Temperature transducer PT100, up to 200°C IN PT100 U,I OUT POWER T-Connector Compatible Temperature transducer PT100, up to 850°C IN 2-, 3- or 4-conductor IEC 751: Pt100/Pt200/Pt500/Pt1000 GOST 6651-2009: Pt100/Pt1000/Cu50/ Cu100/Cu53 JIS C1604-1997: Pt100/Pt1000 DIN 43760: Ni100/Ni1000 -200°C … 850°C (depending on the sensor) linear resistance: 0 … 4 kΩ Can be set via DIP switch or software PT100 2-, 3- or 4-conductor, In accordance with IEC 751; Temperature range: -50°C … +200°C Can be set via DIP switch PT100 2-, 3- or 4-conductor, In accordance with IEC 751; Temperature range: -150°C … +850°C Can be set via DIP switch OUT 0 … 20 mA/4 … 20 mA 20 … 0 mA/20 … 4 mA 0 … 5 V/1 … 5 V 0 … 10 V/10 … 0 V With error signaling Supports fault monitoring Can be set via DIP switch or software 0 … 20 mA/4 … 20 mA 20 … 0 mA/20 … 4 mA 0 … 5 V/1 … 5 V 0 … 10 V/10 … 0 V With error signaling Can be set via DIP switch 0 … 20 mA/4 … 20 mA 20 … 0 mA/20 … 4 mA 0 … 5 V/1 … 5 V 0 … 10 V/10 … 0 V With error signaling Can be set via DIP switch Screw connection MINI MCR-RTD-UI-NC 2902849 MINI MCR-SL-PT100-UI-200-NC 2864370 MINI MCR-SL-PT100-UI-NC 2864273 Spring-cage connection MINI MCR-RTD-UI-SP-NC 2902850 MINI MCR-SL-PT100-UI-200-SP-NC 2864202 MINI MCR-SL-PT100-UI-SP-NC 2864286 Temperature Temperature Temperature IN PT100 I POWER OUT IN T-Connector Compatible Temperature transducer PT100 Supplied by an output loop U,I OUT FM POWER T-Connector Compatible Universal measuring transducer for thermocouples IN U,I POWER PT 100 2-, 3- or 4-conductor, in accordance with IEC 751; Temperature range: -150°C … +300°C Can be set via DIP switch IEC 584-1: B/E/J/K/N/R/S/T DIN 43710: L/U GOST 8.585: A-1/A-2/A-3/M/L -250°C … 2500°C (depending on the sensor) Can be set via DIP switch or software Thermocouples type J or K in accordance with IEC 584-1 Temperature range can be set Can be set via DIP switch OUT 4 … 20 mA/20 … 4 mA With error signaling Can be set via DIP switch 0 … 20 mA/4 … 20 mA 20 … 0 mA/20 … 4 mA 0 … 5 V/1 … 5 V 0 … 10 V/10 … 0 V With error signaling Supports fault monitoring Can be set via DIP switch or software 0 … 20 mA/4 … 20 mA 20 … 0 mA/20 … 4 mA 0 … 5 V/1 … 5 V 0 … 10 V/10 … 0 V With error signaling Can be set via DIP switch MINI MCR-SL-PT100-LP-NC 2810308 Spring-cage connection MINI MCR-SL-PT100-LP-NC-SP 2810395 10 PHOENIX CONTACT RZ_Bro_IF_MiniAnalog_DE.indd 10 MINI MCR-TC-UI-NC 2902851 T-Connector Compatible Temperature transducer for thermocouple types J and K IN Screw connection OUT MINI MCR-SL-TC-UI-NC 2864299 T-Connector Compatible The module can be snapped onto the DIN rail connector. 30.10.12 13:44 MINI Analog – the complete range Frequency Frequency Potentiometer NPN PNP U,I IN IN OUT FM POWER U,I f OUT POWER Frequency transducer, Configurable R IN T-Connector Compatible Analog frequency measuring transducer, Configurable U,I OUT T-Connector Compatible POWER Potentiometer measuring transducer, Configurable IN 0.002 Hz … 20 kHz Can be set via DIP switch 0.002 Hz … 80 kHz Can be set via teach-in wheel 0 … 20 mA/4 … 20 mA, 0 … 5 V/1 … 5 V Can be set via DIP switch 3-wire potentiometer 100 Ω … 100 kΩ Automatic detection OUT 0 … 20 mA/4 … 20 mA 20 … 0 mA/20 … 4 mA 0 … 5 V/1 … 5 V 0 … 10 V/10 … 0 V With error signaling Supports fault monitoring Can be set via DIP switch Frequency output: 0 Hz … 10 kHz/0 Hz … 5 kHz 0 Hz … 2.5 kHz/0 Hz … 1 kHz 0 Hz … 500 Hz/0 Hz … 250 Hz 0 Hz … 100 Hz/0 Hz … 50 Hz PWM output: 7.8 kHz (10 bit)/3.9 kHz (10 bit) 1.9 kHz (12 bit)/977 Hz (12 bit) 488 Hz (14 bit)/244 Hz (14 bit) 122 Hz (16 bit)/61 Hz (16 bit) Can be set via DIP switch 0 … 20 mA/4 … 20 mA 20 … 0 mA/20 … 4 mA 0 … 5 V/1 … 5 V 0 … 10 V/10 … 0 V Can be set via DIP switch Screw connection MINI MCR-SL-F-UI-NC 2902832 MINI MCR-SL-UI-F 2864082 MINI MCR-SL-R-UI 2864095 Spring-cage connection MINI MCR-SL-F-UI-SP-NC 2902833 MINI MCR-SL-UI-F-SP 2810243 MINI MCR-SL-R-UI-SP 2810256 Limit values Digital IN Accessories POWER IN U,I OUT POWER Threshold value switch Configurable IN T-Connector Compatible OUT POWER OUT IN T-Connector Compatible NAMUR signal conditioner, Configurable IN 0 … 20 mA 0 … 10 V Can be set via DIP switch NAMUR proximity sensors, Floating switch contacts, Switch contacts with resistance circuit Can be set via DIP switch OUT 1 relay contact (PDT) Threshold value can be set via potentiometer 2 N/O contacts, 1 N/O contact for use as fault signal Can be set via DIP switch UCV Constant voltage source, Configurable 9.6 … 30 V DC 2.5 V DC/5 V DC/7.5 V DC/10 V DC Screw connection MINI MCR-SL-UI-REL 2864480 MINI MCR-SL-NAM-2RNO 2864105 MINI MCR-SL-CVS-24-5-10-NC 2902822 Spring-cage connection MINI MCR-SL-UI-REL-SP 2864493 MINI MCR-SL-NAM-2RNO-SP 2810269 MINI MCR-SL-CVS-24-5-10-SP-NC 2902823 T-Connector Compatible The module can be snapped onto the DIN rail connector. RZ_Bro_IF_MiniAnalog_DE.indd 11 PHOENIX CONTACT 11 30.10.12 13:44 Quick and error-free wiring with system cabling Time savings of up to 95%: the MINI Analog system cabling gives you two options for quick and error-free wiring: MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI MINI MCR-RTD-UI 2. MINI Analog termination carrier • For large numbers of channels • Enables module replacement during operation MINI MCR-RTD-UI 1. MINI Analog system adapter • For up to eight channels The system adapter allows you to wire eight analog channels on the signal conditioner and controller side quickly and without errors. Plug & Play with the MINI Analog system adapter 12 Phoenix ContaCt RZ_Bro_IF_MiniAnalog_DE.indd 12 30.10.12 13:45 Compact For high packing density • Space savings of up to 30%, thanks to compact design • Space-saving connection points • Integrated end clamps Robust For high system availability • Stable, vibration-resistant aluminum carrier device profile • Mechanically decoupled termination PCB • Passive PCB without active components • Redundant supply and monitoring electronics in a separate DIN rail device Easy maintenance Hot-swappable system cabling with the termination carrier For simplified documentation and startup • Use of standard DIN rail devices • Easily accessible connection points • Module replacement during operation (hot swap) • Pre-assembled system cabling with front adapter Flexible For optimum adaptation • Gridless profile lengths for controller-specific number of I/Os • Different system plug types, including redundant • Horizontal and vertical mounting When used in combination with MINI Analog, the termination carrier offers unique packing density: install up to 320 channels in an 80 x 200 cm control cabinet. Phoenix Contact offers a comprehensive range of system cables for specific higher-level control systems. MI M M MINI MCR MCR-SL-PTB CR R SL-PT RR-S SLS L L- PT PTB P TB B MI M M MINI MCR MCR-SL-TB CR R SL-TB RR-S SLS L L-TB TB In addition to universal termination carriers, versions which are tailored to your higher-level control system are also available. Please contact us for more information. Phoenix ContaCt RZ_Bro_IF_MiniAnalog_DE.indd 13 13 30.10.12 13:45 Accessories for MINI Analog System adapter MINI MCR-SL-V8-FLK 16-A Order No. 2811268 MINI Analog system adapter for all MINI Analog modules with screw connection FLK 16/ EZ-DR/…/KONFEK FLK 16 cables in various lengths (see INTERFACE catalog) FLKM 16… VARIOFACE front adapter for SIMATIC S7-300 (see INTERFACE catalog) DIN rail connector Termination carrier TC-D37SUB-ADIO16-M-P-UNI Order No. 2902933 • For 16 MINI Analog devices + 1 x power module and 1 x feed-through terminal block • With 1:1 pinning to DSUB37 TC-D37SUB-AIO16-M-PS-UNI Order No. 2902934 • For 16 MINI Analog devices + 1 x power module and 1 x feed-through terminal block • With 1:1 pinning to DSUB37 • Additional HART decoupling option Power terminal blocks, can be monitored MINI Analog multiplexer MINI MCR-SL-MUX-V8-FLK 16 Order No. 2811815 Can be combined with MINI MCR-… or MINI MCR-SL-TB feed-through terminal block with existing isolation • Input: 8 x 4…20 mA • Output: 1 x 4…20 mA + 3x digital Cables: VIP-CAB-FLK16/FR/OE/0,14/… (see INTERFACE catalog) CABLE-FLK16/OE/0,14/… (see INTERFACE catalog) Fault monitoring module ME 6,2 TBUS-2 1,5/5-ST-3,81 GN Order No. 2869728 MINI MCR-SL-PTB-FM Order No. 2902958 MINI MCR-SL-FM-RC-NC Order No. 2902961 For two MINI Analog modules each Screw connection Screw connection ME 17,5 TBUS 1,5/5-ST-3,81 GN Order No. 2709561 MINI MCR-SL-PTB-FM-SP Order No. 2902959 For MINI-SYS system power supply (2 required) Spring-cage connection 14 • Inputs: 0…30 V DC • Output: max. 2 A; 0…29.2 V • Monitoring of the supply possible in combination with the fault monitoring module MINI MCR-SL-FM-RC-SP-NC Order No. 2902962 Spring-cage connection • For evaluating and reporting group errors from the fault monitoring system • Supply voltage monitoring of the PTB-FM module Phoenix ContaCt RZ_Bro_IF_MiniAnalog_DE.indd 14 30.10.12 13:45 Accessories for MINI Analog Feed-through terminal block Surge protection MINI MCR-SL-TB Order No. 2811420 LINETRAB LIT Highly compact surge protection For 1:1 forwarding of signals • Same shape as the MINI Analog • Quick and easy to connect to MINI Analog thanks to the standard system cabling • More detailed information on the Internet under Surge protection • For increasing to eight modules when using the system adapter or multiplexer System power supply Programming adapter Marking MINI-SYS-PS-100-240AC/24DC/1.5 Order No. 2866983 IFS-USB-PROG-ADAPTER Order No. 2811271 MINI MCR DKL Order No. 2308111 MINI-PS-100-240AC/24DC/1.5/EX Order No. 2866653 (Ex n-capable) Programming adapter with USB interface, for programming using software Hinged transparent cover with opening for insert strips • Wide range input: 85…264 V AC (45 – 65 Hz) • Output voltage: 24 V DC ± 1% • Output current: 1.5 A at 60°C/2 A at 40°C • The software is available on the Internet free of charge. MINI MCR-DKL-LABEL Order No. 2810272 Insert strips, for transparent MINI cover ZBF6… Flat-ribbon labeling Phoenix ContaCt RZ_Bro_IF_MiniAnalog_DE.indd 15 15 30.10.12 13:45 Further information on the products presented here and on the world of solutions from Phoenix Contact can be found at www.phoenixcontact.net/products Modular Terminal Blocks CLIPLINE 1 Marking Systems, Tools, and Mounting Material CLIPLINE 2 Or contact us directly. Connection Technology for Field Devices and Field Cabling PLUSCON INTERFACE Automation Components and Systems AUTOMATION PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg, Germany Phone: +49 (0) 52 35 3-00 Fax: +49 (0) 52 35 3-4 12 00 www.phoenixcontact.com RZ_Bro_IF_MiniAnalog_DE.indd 16 Printed in Germany Signal Converters, Switching Devices, Power Supply Units MNR 5170883/15.11.2012-04 Power and Signal Quality TRABTECH © PHOENIX CONTACT 2012 Device Connection Technology and Electronic Housings COMBICON 30.10.12 13:45