Highly compact signal conditioners MINI Analog

Highly compact
signal conditioners
MINI Analog
RZ_Bro_IF_MiniAnalog_DE.indd 1
30.10.12 13:42
Highly compact signal conditioners –
MINI Analog creates space in your
control cabinet
Maximum signal quality with minimal
space requirements – MINI Analog signal
conditioners isolate, convert, filter, and
amplify your analog signals – with a design
width of just 6.2 mm.
Time-saving
system cabling
Plug & Play – for eight
channels on the signal
conditioner and controller
side
Fault monitoring and
power bridging
The DIN rail connector
simplifies supply and
enables convenient group
error monitoring.
Significant space savings
Worldwide use, thanks to the international
approval package
2
Space savings of up to 65%
compared to other signal
conditioners on the market
thanks to the 6.2 mm design
width
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 2
30.10.12 13:42
Convenient configuration
and monitoring
The configurable MINI Analog modules are
easy to set with DIP switches – without
the need for any software. Alternatively,
Phoenix Contact can make the settings based
on your individual ordering information.
For enhanced functionality and monitoring,
you can also configure the modules with the
robust S-Port interface conveniently using a
free-of-charge software interface. Here you
can choose between three solutions:
1. Standalone ANALOG-CONF software
2. FDT/DTM software package
3. Standalone DTMs, allowing you to use your
existing FDT frame application
Product overview
Signal conditioners
Analog IN/
Analog OUT
2-wire
• Universal and standard 3-way isolators
• 3-way repeater power supplies
• 4-way signal duplicators
• 2-way passive isolators
• 2-way loop-powered isolators
3-wire
4-wire
Page 8
Temperature transducers
Temperature
• Universal and standard measuring
transducers for thermocouples
• Universal and standard measuring
transducers for resistance thermometers
• Loop-powered PT100 measuring
transducers
Page 10
Frequency transducers
Frequency
• Frequency transducers
• Analog frequency transducers
Page 11
Potentiometer measuring transducers
Potentiometers
• with automatic potentiometer detection
Page 11
Threshold value switches
Limit values
+
+
I
• Threshold value switches with PDT relay
U
-
-
NAMUR signal conditioners
Digital IN
-
+
Accessories
Page 11
-
-
+
+
• NAMUR signal conditioners with
relay output
Page 11
• Supply components
• Fault monitoring module
• System cabling
• Multiplexer
• Labeling material
Page 14
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 3
3
30.10.12 13:43
Highly compact MINI Analog
signal conditioners – your advantages
The product range provides maximum
efficiency in terms of
• Space requirements
• Costs
• Power consumption
• Planning and installation
• Configuration
Maximum signal quality with
minimal space requirements
High energy efficiency
and long service life
Module width 6.2 mm
62 mm
Power consumption
65% space saving
175 mm
Module width 17.5 mm
With the narrow MINI Analog modules, you can save
up to 65% space compared to other signal conditioners
on the market that have a design width of 12.5 mm to
22.5 mm.
4
100%
Other signal conditioners
on the market
25%
MINI Analog
t
With MINI Analog, the energy-efficient design of your
automation processes starts in the control cabinet:
The modules have low power consumption, thanks to
their innovative circuit design. As a result the modules
heat up less and therefore have a longer life. You can
therefore achieve a high level of operational reliability
across the entire operating temperature range, even
when arranged in series.
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 4
30.10.12 13:43
Power supply – flexible and easy
MINI Analog signal conditioners offer a system solution for
supplying devices: use the DIN rail connector to bridge the
DC supply voltage. This simplifies wiring, system expansion
or module replacement, even during operation.
The DIN rail connector gives you three device supply
options:
1. Direct DC supply at any MINI Analog module:
• For up to 16 MINI Analog modules
• No additional accessories required other
than the DIN rail connector
2. Via a power module of the same shape:
• For up to 80 MINI Analog modules
• Also allows redundant supply
and supply monitoring
3. Via the system power supply unit
with wide range input 85…264 V AC:
• If no DC supply is available
• For up to 60 MINI Analog modules
2
Power IN
2
Power IN
1
Power IN
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
Power
module
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MIN M
MINI
M
MCRR-R
RTD-U
-UI
UII
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
3
MINI MCR-RTD-UI
Power
supply unit
Power IN
Convenient error evaluation with fault monitoring
It is also possible to detect and signal the failure
of a supply voltage at the power terminal block.
The modularity is characterized by the ability to
freely adjust the error evaluation, both on the
device side and in the evaluation module.
Error
message
contact
Power IN
Power
module
MINI MCR-SL-PTB-FM
Fault
monitoring
module
MINI MCR-SL-FM-RC
Fault monitoring is a modular solution for
convenient error evaluation in multi-channel
applications. Depending on the module type, the
following errors can be indicated by means of a
group error message:
• Measuring range overshot
• Measuring range undershot
• Open circuit
• Short circuit
• Module error
Group
error message
For up to 80 devices
F85 2-6
F85 2-6
F85 2-6
F85 2-6
Supply voltage monitoring
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 5
5
30.10.12 13:44
Reduction in analog
inputs at controllers
1x
Analo
The MINI Analog multiplexer enables you
to reduce up to eight analog signals to a
single 4...20 mA signal.
g
8x
Analo
Simply ingenious
An easy DIP switch
configuration allows you to
choose between 2-, 4-, 6- or
8-channel operation. The
channels are switched over in
1- or 2-second cycles.
g
The channel currently switched
is detected via three digital
outputs using a bit pattern.
Straightforward configuration via DIP switch
Temperature measurement in
wind power plants
A wide range of temperatures
are measured in wind power
plants. As a general rule, at least
6 measuring points are monitored.
The MINI Analog multiplexer
reduces these signals to just one
and thereby lowers the number
of analog inputs at the central
acquisition point.
MINI MCR-SL-UI-UI
MCR-SL-PT 100
MINI MCR-SL-UI-UI
MCR-SL-PT 100
8
7
6
5
1
2
3
4
8
7
6
5
1
2
3
4
MINI MCR-SL-UI-UI
MCR-SL-PT 100
8
7
6
5
1
2
3
4
MINI MCR-SL-UI-UI
MCR-SL-PT 100
8
7
6
5
1
2
3
4
MINI MCR-SL-UI-UI
MCR-SL-PT 100
8
7
6
5
1
2
3
4
MINI MCR-SL-UI-UI
MCR-SL-PT 100
8x Analog IN
6
8
7
6
5
1
2
3
4
MINI MCR-SL-UI-UI
MCR-SL-PT 100
1x Analog IN
SF
4…20 mA
8
7
6
5
MINI MCR-SL-UI-UI
MCR-SL-PT 100
Power
8
7
6
5
1
2
3
4
8 x PT100
3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1
1
2
3
4
At the same time, the amount
of cabling can be significantly
reduced, for example, directly at
the generator. The signal is then
directly converted on-site to a
4...20 mA signal, electrically
isolated and amplified.
AO
DO
DO
DO
MINI
MCR-SL-MUX
RUN-P
RUN
Controller
BATF
0
0
0
DC5V
1
1
1
FRCE
2
2
2
RUN
3
3
3
STOP
4
4
4
5
5
5
6
6
6
7
7
7
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
STOP
MRES
3 x Digital IN
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 6
30.10.12 13:44
Isolating, converting, filtering, and amplifying – the functions at a glance
Electrical isolation
The most important task of a signal
conditioner is the electrical isolation of
signals. MINI Analog offers consistent
isolation of input, output, and supply.
As such, ground current loops can be
prevented in the event of potential
differences, which would otherwise lead
to a distortion of the measured process
values.
PLC
RUN
FAIL
MRESET
STP
11
RUN/PROG
13
ETH
15
12
17
14
19
16
18
I11
Q1
I10
Q3
I12
E
US
Q2
UL
Q4
UM
10/100 BASE-T
LNK
ACT
100
Ig ≠ I1
Sensor
INLINE CONTROL
ILC 350 ETH
Ord.No.: 2737203
RESET
IL
PRG
RDY/RUN
BSA
FAIL
PF
I2
Ground
current loop
Potential 2
Potential 1
PLC
RUN
FAIL
MRESET
STP
11
RUN/PROG
13
ETH
Ig = I1
Sensor
15
12
17
14
19
16
I11
18
Q1
I10
Q3
I12
E
US
Q2
UL
Q4
UM
10/100 BASE-T
LNK
ACT
100
INLINE CONTROL
ILC 350 ETH
Ord.No.: 2737203
RESET
IL
PRG
RDY/RUN
BSA
FAIL
PF
I2 = 0
No ground
current loop
Potential 1
Potential 1
Converting signals
An advantage of signal conversion is
the conversion of sensor signals into a
signal that can be read by the controller,
such as PT100 in 4...20 mA. In addition,
failure-prone signals such as 0 - 10 V, for
example, can be converted into non-prone
current signals.
Amplifying signals
Signals always need to be amplified in the
event that cables are long or if high loads
are to be driven. It is here where the
signal conditioners of the MINI Analog
range provide a high output power at a
low input power.
STP
11
13
15
12
19
16
I11
18
Q1
I10
Q3
I12
E
US
Q2
UL
Q4
UM
0 – 10 V
4 – 20 mA
INLINE CONTROL
ILC 350 ETH
Ord.No.: 2737203
RESET
IL
PRG
Can only drive loads
of up to 300 Ω
Can amplify loads
of up to 500 Ω
RDY/RUN
BSA
FAIL
PF
MRESET
STP
PLC
RUN
FAIL
11
RUN/PROG
13
ETH
15
12
14
17
19
16
18
E
Q1
I11
I10
I12
Q3
Q2
Q4
US
UL
UM
10/100 BASE-T
Sensor
4 – 20 mA
LNK
ACT
100
4 – 20 mA
INLINE CONTROL
ILC 350 ETH
Ord.No.: 2737203
RESET
PRG
U
IL
RDY/RUN
BSA
FAIL
PF
U
t
t
MRESET
STP
PLC
RUN
FAIL
11
RUN/PROG
13
ETH
Sensor
17
14
10/100 BASE-T
Sensor
Filtering signals
In industrial environments, interference
often occurs as a result of high-frequency
signals. The input filters of the
MINI Analog signal conditioners therefore
reliably filter out such interfering signals.
PLC
RUN
FAIL
MRESET
RUN/PROG
ETH
LNK
ACT
100
15
12
14
17
19
16
18
I11
Q1
I10
I12
Q3
E
Q2
Q4
US
UL
UM
10/100 BASE-T
0 – 10 V
0 – 10 V
LNK
ACT
100
INLINE CONTROL
ILC 350 ETH
Ord.No.: 2737203
RESET
PRG
IL
RDY/RUN
BSA
FAIL
PF
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 7
7
30.10.12 13:44
MINI Analog – the complete range
Analog IN/Analog OUT
IN
U,I
U,I
OUT
POWER
Analog IN/Analog OUT
IN
T-Connector
Compatible
3-way signal conditioner,
Configurable
U
U,I
Analog IN/Analog OUT
IN
OUT
U
T-Connector
Compatible
POWER
3-way signal conditioner,
Configurable
U,I
OUT
T-Connector
Compatible
POWER
3-way signal conditioner,
Configurable
IN
0 … 20 mA/4 … 20 mA
0 … 5 V/1 … 5 V
0 … 10 V/2 … 10 V
Can be set via DIP switch
Unipolar/bipolar:
0 … 50 mV/0 … 60 mV/0 … 75 mV/0 … 80 mV/
0 … 100 mV/0 … 120 mV/0 … 150 mV/
0 … 200 mV/0 … 240 mV/0 … 300 mV/
0 … 500 mV/0 … 600 mV/0 … 750 mV/
0 … 800 mV/0 … 1 V/0 … 1.2 V/0 … 1.5 V/
0 … 2 V/0 … 2.4 V/0 … 3 V
Can be set via DIP switch
0 … 24 V/0 … 30 V
Can be set via DIP switch
OUT
0 … 20 mA/4 … 20 mA
0 … 5 V/1 … 5 V
0 … 10 V/2 … 10 V
Can be set via DIP switch
0 ... 20 mA/4 ... 20 mA
0 ... 5 V/1 ... 5 V
0 ... 10 V/2 ... 10 V
-5 ... 5 V/-10 ... 10 V
Can be set via DIP switch
0 ... 20 mA/4 ... 20 mA
0 ... 5 V/1 ... 5 V
0 ... 10 V/2 ... 10 V
Can be set via DIP switch
Screw
connection
MINI MCR-SL-UI-UI-NC
2864150
MINI MCR-SL-SHUNT-UI-NC
2810780
MINI MCR-SL-U-UI-NC
2865007
Spring-cage
connection
MINI MCR-SL-UI-UI-SP-NC
2864163
MINI MCR-SL-SHUNT-UI-SP-NC
2810793
MINI MCR-SL-U-UI-SP-NC
2810078
Analog IN/Analog OUT
Analog IN/Analog OUT
Analog IN/Analog OUT
IN
U,I
U,I
OUT
POWER
3-way signal conditioner,
With fixed signal combinations
IN
T-Connector
Compatible
U
I
OUT
T-Connector
Compatible
POWER
3-way signal conditioner,
With fixed signal combinations
IN
I
U
OUT
POWER
T-Connector
Compatible
3-way signal conditioner,
With fixed signal combinations
IN
1) 0 … 20 mA/4 … 20 mA
2) 0 … 10 V/-10 … 10 V
0 … 10 V
1) 0 … 20 mA
2) 4 … 20 mA
OUT
1) 0 … 20 mA/4 … 20 mA
2) 0 … 10 V/-10 … 10 V
1) 0 … 20 mA
2) 4 … 20 mA
0 … 10 V
Screw
connection
1) MINI MCR-SL-I-I
2864406
2) MINI MCR-SL-U-U
2864684
1) MINI MCR-SL-U-I-0
2813512
2) MINI MCR-SL-U-I-4
2813525
1) MINI MCR-SL-I-U-0
2813541
2) MINI MCR-SL-I-U-4
2813538
Spring-cage
connection
1) MINI MCR-SL-I-I-SP
2864723
2) MINI MCR-SL-U-U-SP
2864697
1) MINI MCR-SL-U-I-0-SP
2813570
2) MINI MCR-SL-U-I-4-SP
2813583
1) MINI MCR-SL-I-U-0-SP
2813554
2) MINI MCR-SL-I-U-4-SP
2813567
8
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 8
T-Connector
Compatible
The module can be snapped onto the
DIN rail connector.
30.10.12 13:44
MINI Analog – the complete range
Analog IN/Analog OUT
Analog IN/Analog OUT
Analog IN/Analog OUT
OUT1
I
IN
U,I
I
OUT2
POWER
I
IN
T-Connector
Compatible
I
OUT
POWER
T-Connector
Compatible
IN
I
I
OUT
POWER
POWER
Signal duplicator,
Configurable
Repeater power supply
Repeater power supply
transparent
POWER
T-Connector
Compatible
IN
0 … 20 mA/4 … 20 mA
0 … 10 V/1 … 5 V
Can be set via DIP switch
Isolator operation: 0 … 20 mA/4 … 20 mA
Repeater power supply operation: 4 … 20 mA
Isolator operation: 0 … 20 mA/4 … 20 mA
Repeater power supply operation: 4 … 20 mA
OUT
2 x 0 … 20 mA/2 x 4 … 20 mA
Can be set via DIP switch
0 … 20 mA/4 … 20 mA
0 … 20 mA/4 … 20 mA
Screw
connection
MINI MCR-SL-UI-2I-NC
2864176
MINI MCR-SL-RPS-I-I
2864422
MINI MCR-SL-RPSS-I-I
2864079
Spring-cage
connection
MINI MCR-SL-UI-2I-SP-NC
2864189
MINI MCR-SL-RPS-I-I-SP
2864752
MINI MCR-SL-RPSS-I-I-SP
2810230
Analog IN/Analog OUT
Analog IN/Analog OUT
U, I
IN
I
I
OUT
T-Connector
Compatible
Passive isolator
Supplied by an input loop
IN
POWER
IN
1) 0 … 20 mA/4 … 20 mA
2) 2 x 0 … 20 mA/2 x 4 … 20 mA
OUT
I
Loop-powered isolator
Supplied by an output loop
0 … 2 mA to 0 … 40 mA (16 ranges)
Unipolar and bipolar:
0 … 50 mV to 0 … 30 V (58 ranges)
Can be set via DIP switch
OUT
1) 0 … 20 mA/4 … 20 mA
2) 2 x 0 … 20 mA/2 x 4 … 20 mA
4 … 20 mA
Screw
connection
1) MINI MCR-SL-1CP-I-I
2864419
2) MINI MCR-SL-2CP-I-I
2864655
MINI MCR-SL-UI-I-LP-NC
2902829
Spring-cage
connection
1) MINI MCR-SL-1CP-I-I-SP
2864749
2) MINI MCR-SL-2CP-I-I-SP
2864781
MINI MCR-SL-UI-I-LP-SP-NC
2902830
T-Connector
Compatible
The module can be snapped onto the
DIN rail connector.
RZ_Bro_IF_MiniAnalog_DE.indd 9
Order configuration
You can order your desired
device configuration easily and
flexibly:
• Using order keys from the
catalog or
• In the user-guided e-shop
www.phoenixcontact.net/catalog
PHOENIX CONTACT
9
30.10.12 13:44
MINI Analog – the complete range
Temperature
U,I
IN
Temperature
OUT
T-Connector
Compatible
FM
POWER
Universal measuring transducer
for resistance thermometers
IN
PT100
U,I
Temperature
OUT
POWER
T-Connector
Compatible
Temperature transducer PT100,
up to 200°C
IN
PT100
U,I
OUT
POWER
T-Connector
Compatible
Temperature transducer PT100,
up to 850°C
IN
2-, 3- or 4-conductor
IEC 751: Pt100/Pt200/Pt500/Pt1000
GOST 6651-2009: Pt100/Pt1000/Cu50/
Cu100/Cu53
JIS C1604-1997: Pt100/Pt1000
DIN 43760: Ni100/Ni1000
-200°C … 850°C (depending on the sensor)
linear resistance: 0 … 4 kΩ
Can be set via DIP switch or software
PT100 2-, 3- or 4-conductor,
In accordance with IEC 751;
Temperature range: -50°C … +200°C
Can be set via DIP switch
PT100 2-, 3- or 4-conductor,
In accordance with IEC 751;
Temperature range: -150°C … +850°C
Can be set via DIP switch
OUT
0 … 20 mA/4 … 20 mA
20 … 0 mA/20 … 4 mA
0 … 5 V/1 … 5 V
0 … 10 V/10 … 0 V
With error signaling
Supports fault monitoring
Can be set via DIP switch or software
0 … 20 mA/4 … 20 mA
20 … 0 mA/20 … 4 mA
0 … 5 V/1 … 5 V
0 … 10 V/10 … 0 V
With error signaling
Can be set via DIP switch
0 … 20 mA/4 … 20 mA
20 … 0 mA/20 … 4 mA
0 … 5 V/1 … 5 V
0 … 10 V/10 … 0 V
With error signaling
Can be set via DIP switch
Screw
connection
MINI MCR-RTD-UI-NC
2902849
MINI MCR-SL-PT100-UI-200-NC
2864370
MINI MCR-SL-PT100-UI-NC
2864273
Spring-cage
connection
MINI MCR-RTD-UI-SP-NC
2902850
MINI MCR-SL-PT100-UI-200-SP-NC
2864202
MINI MCR-SL-PT100-UI-SP-NC
2864286
Temperature
Temperature
Temperature
IN
PT100
I
POWER
OUT
IN
T-Connector
Compatible
Temperature transducer PT100
Supplied by an output loop
U,I
OUT
FM
POWER
T-Connector
Compatible
Universal measuring transducer
for thermocouples
IN
U,I
POWER
PT 100 2-, 3- or 4-conductor,
in accordance with IEC 751;
Temperature range: -150°C … +300°C
Can be set via DIP switch
IEC 584-1: B/E/J/K/N/R/S/T
DIN 43710: L/U
GOST 8.585: A-1/A-2/A-3/M/L
-250°C … 2500°C (depending on the sensor)
Can be set via DIP switch or software
Thermocouples type J or K
in accordance with IEC 584-1
Temperature range can be set
Can be set via DIP switch
OUT
4 … 20 mA/20 … 4 mA
With error signaling
Can be set via DIP switch
0 … 20 mA/4 … 20 mA
20 … 0 mA/20 … 4 mA
0 … 5 V/1 … 5 V
0 … 10 V/10 … 0 V
With error signaling
Supports fault monitoring
Can be set via DIP switch or software
0 … 20 mA/4 … 20 mA
20 … 0 mA/20 … 4 mA
0 … 5 V/1 … 5 V
0 … 10 V/10 … 0 V
With error signaling
Can be set via DIP switch
MINI MCR-SL-PT100-LP-NC
2810308
Spring-cage
connection
MINI MCR-SL-PT100-LP-NC-SP
2810395
10
PHOENIX CONTACT
RZ_Bro_IF_MiniAnalog_DE.indd 10
MINI MCR-TC-UI-NC
2902851
T-Connector
Compatible
Temperature transducer for
thermocouple types J and K
IN
Screw
connection
OUT
MINI MCR-SL-TC-UI-NC
2864299
T-Connector
Compatible
The module can be snapped onto the
DIN rail connector.
30.10.12 13:44
MINI Analog – the complete range
Frequency
Frequency
Potentiometer
NPN
PNP
U,I
IN
IN
OUT
FM
POWER
U,I
f
OUT
POWER
Frequency transducer,
Configurable
R
IN
T-Connector
Compatible
Analog frequency measuring transducer,
Configurable
U,I
OUT
T-Connector
Compatible
POWER
Potentiometer measuring transducer,
Configurable
IN
0.002 Hz … 20 kHz
Can be set via DIP switch
0.002 Hz … 80 kHz
Can be set via teach-in wheel
0 … 20 mA/4 … 20 mA,
0 … 5 V/1 … 5 V
Can be set via DIP switch
3-wire potentiometer
100 Ω … 100 kΩ
Automatic detection
OUT
0 … 20 mA/4 … 20 mA
20 … 0 mA/20 … 4 mA
0 … 5 V/1 … 5 V
0 … 10 V/10 … 0 V
With error signaling
Supports fault monitoring
Can be set via DIP switch
Frequency output:
0 Hz … 10 kHz/0 Hz … 5 kHz
0 Hz … 2.5 kHz/0 Hz … 1 kHz
0 Hz … 500 Hz/0 Hz … 250 Hz
0 Hz … 100 Hz/0 Hz … 50 Hz
PWM output:
7.8 kHz (10 bit)/3.9 kHz (10 bit)
1.9 kHz (12 bit)/977 Hz (12 bit)
488 Hz (14 bit)/244 Hz (14 bit)
122 Hz (16 bit)/61 Hz (16 bit)
Can be set via DIP switch
0 … 20 mA/4 … 20 mA
20 … 0 mA/20 … 4 mA
0 … 5 V/1 … 5 V
0 … 10 V/10 … 0 V
Can be set via DIP switch
Screw
connection
MINI MCR-SL-F-UI-NC
2902832
MINI MCR-SL-UI-F
2864082
MINI MCR-SL-R-UI
2864095
Spring-cage
connection
MINI MCR-SL-F-UI-SP-NC
2902833
MINI MCR-SL-UI-F-SP
2810243
MINI MCR-SL-R-UI-SP
2810256
Limit values
Digital IN
Accessories
POWER
IN
U,I
OUT
POWER
Threshold value switch
Configurable
IN
T-Connector
Compatible
OUT
POWER
OUT
IN
T-Connector
Compatible
NAMUR signal conditioner,
Configurable
IN
0 … 20 mA
0 … 10 V
Can be set via DIP switch
NAMUR proximity sensors,
Floating switch contacts,
Switch contacts with resistance circuit
Can be set via DIP switch
OUT
1 relay contact (PDT)
Threshold value can be set via
potentiometer
2 N/O contacts, 1 N/O contact
for use as fault signal
Can be set via DIP switch
UCV
Constant voltage source,
Configurable
9.6 … 30 V DC
2.5 V DC/5 V DC/7.5 V DC/10 V DC
Screw
connection
MINI MCR-SL-UI-REL
2864480
MINI MCR-SL-NAM-2RNO
2864105
MINI MCR-SL-CVS-24-5-10-NC
2902822
Spring-cage
connection
MINI MCR-SL-UI-REL-SP
2864493
MINI MCR-SL-NAM-2RNO-SP
2810269
MINI MCR-SL-CVS-24-5-10-SP-NC
2902823
T-Connector
Compatible
The module can be snapped onto the
DIN rail connector.
RZ_Bro_IF_MiniAnalog_DE.indd 11
PHOENIX CONTACT
11
30.10.12 13:44
Quick and error-free wiring
with system cabling
Time savings of up to 95%: the MINI Analog
system cabling gives you two options for
quick and error-free wiring:
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
MINI MCR-RTD-UI
2. MINI Analog termination carrier
• For large numbers of channels
• Enables module replacement
during operation
MINI MCR-RTD-UI
1. MINI Analog system adapter
• For up to eight channels
The system adapter allows you to
wire eight analog channels on the
signal conditioner and controller
side quickly and without errors.
Plug & Play with the
MINI Analog system adapter
12
Phoenix ContaCt
RZ_Bro_IF_MiniAnalog_DE.indd 12
30.10.12 13:45
Compact
For high packing density
• Space savings of up to 30%, thanks to compact design
• Space-saving connection points
• Integrated end clamps
Robust
For high system availability
• Stable, vibration-resistant aluminum carrier device profile
• Mechanically decoupled termination PCB
• Passive PCB without active components
• Redundant supply and monitoring electronics
in a separate DIN rail device
Easy maintenance
Hot-swappable system cabling
with the termination carrier
For simplified documentation and startup
• Use of standard DIN rail devices
• Easily accessible connection points
• Module replacement during operation (hot swap)
• Pre-assembled system cabling with front adapter
Flexible
For optimum adaptation
• Gridless profile lengths for controller-specific number
of I/Os
• Different system plug types, including redundant
• Horizontal and vertical mounting
When used in combination with MINI Analog, the
termination carrier offers unique packing density:
install up to 320 channels in an 80 x 200 cm
control cabinet. Phoenix Contact offers a
comprehensive range of system cables for specific
higher-level control systems.
MI M
M
MINI
MCR
MCR-SL-PTB
CR
R SL-PT
RR-S
SLS
L
L- PT
PTB
P
TB
B
MI M
M
MINI
MCR
MCR-SL-TB
CR
R SL-TB
RR-S
SLS
L
L-TB
TB
In addition to universal termination carriers, versions
which are tailored to your higher-level control system
are also available.
Please contact us for more information.
Phoenix ContaCt
RZ_Bro_IF_MiniAnalog_DE.indd 13
13
30.10.12 13:45
Accessories for MINI Analog
System adapter
MINI MCR-SL-V8-FLK 16-A
Order No. 2811268
MINI Analog system adapter for all
MINI Analog modules with screw connection
FLK 16/ EZ-DR/…/KONFEK
FLK 16 cables in various lengths
(see INTERFACE catalog)
FLKM 16…
VARIOFACE front adapter for
SIMATIC S7-300
(see INTERFACE catalog)
DIN rail connector
Termination carrier
TC-D37SUB-ADIO16-M-P-UNI
Order No. 2902933
• For 16 MINI Analog devices + 1 x power
module and 1 x feed-through terminal block
• With 1:1 pinning to DSUB37
TC-D37SUB-AIO16-M-PS-UNI
Order No. 2902934
• For 16 MINI Analog devices + 1 x power
module and 1 x feed-through terminal block
• With 1:1 pinning to DSUB37
• Additional HART decoupling option
Power terminal blocks,
can be monitored
MINI Analog multiplexer
MINI MCR-SL-MUX-V8-FLK 16
Order No. 2811815
Can be combined with
MINI MCR-… or MINI MCR-SL-TB
feed-through terminal block with
existing isolation
• Input: 8 x 4…20 mA
• Output: 1 x 4…20 mA + 3x digital
Cables:
VIP-CAB-FLK16/FR/OE/0,14/…
(see INTERFACE catalog)
CABLE-FLK16/OE/0,14/…
(see INTERFACE catalog)
Fault monitoring module
ME 6,2 TBUS-2 1,5/5-ST-3,81 GN
Order No. 2869728
MINI MCR-SL-PTB-FM
Order No. 2902958
MINI MCR-SL-FM-RC-NC
Order No. 2902961
For two MINI Analog modules each
Screw connection
Screw connection
ME 17,5 TBUS 1,5/5-ST-3,81 GN
Order No. 2709561
MINI MCR-SL-PTB-FM-SP
Order No. 2902959
For MINI-SYS system power supply
(2 required)
Spring-cage connection
14
• Inputs: 0…30 V DC
• Output: max. 2 A; 0…29.2 V
• Monitoring of the supply possible in
combination with the fault
monitoring module
MINI MCR-SL-FM-RC-SP-NC
Order No. 2902962
Spring-cage connection
• For evaluating and reporting group errors
from the fault monitoring system
• Supply voltage monitoring of the
PTB-FM module
Phoenix ContaCt
RZ_Bro_IF_MiniAnalog_DE.indd 14
30.10.12 13:45
Accessories for MINI Analog
Feed-through terminal block
Surge protection
MINI MCR-SL-TB
Order No. 2811420
LINETRAB LIT
Highly compact surge protection
For 1:1 forwarding of signals
• Same shape as the MINI Analog
• Quick and easy to connect to MINI Analog
thanks to the standard system cabling
• More detailed information on the Internet
under Surge protection
• For increasing to eight modules when
using the system adapter or multiplexer
System power supply
Programming adapter
Marking
MINI-SYS-PS-100-240AC/24DC/1.5
Order No. 2866983
IFS-USB-PROG-ADAPTER
Order No. 2811271
MINI MCR DKL
Order No. 2308111
MINI-PS-100-240AC/24DC/1.5/EX
Order No. 2866653 (Ex n-capable)
Programming adapter with USB interface,
for programming using software
Hinged transparent cover with opening
for insert strips
• Wide range input:
85…264 V AC (45 – 65 Hz)
• Output voltage:
24 V DC ± 1%
• Output current:
1.5 A at 60°C/2 A at 40°C
• The software is available on the Internet
free of charge.
MINI MCR-DKL-LABEL
Order No. 2810272
Insert strips, for transparent MINI cover
ZBF6…
Flat-ribbon labeling
Phoenix ContaCt
RZ_Bro_IF_MiniAnalog_DE.indd 15
15
30.10.12 13:45
Further information on the products
presented here and on the world of solutions
from Phoenix Contact can be found at
www.phoenixcontact.net/products
Modular Terminal Blocks
CLIPLINE 1
Marking Systems, Tools, and
Mounting Material
CLIPLINE 2
Or contact us directly.
Connection Technology for
Field Devices and Field Cabling
PLUSCON
INTERFACE
Automation Components
and Systems
AUTOMATION
PHOENIX CONTACT GmbH & Co. KG
32823 Blomberg, Germany
Phone: +49 (0) 52 35 3-00
Fax:
+49 (0) 52 35 3-4 12 00
www.phoenixcontact.com
RZ_Bro_IF_MiniAnalog_DE.indd 16
Printed in Germany
Signal Converters, Switching Devices,
Power Supply Units
MNR 5170883/15.11.2012-04
Power and Signal Quality
TRABTECH
© PHOENIX CONTACT 2012
Device Connection Technology
and Electronic Housings
COMBICON
30.10.12 13:45