Highly compact signal conditioners with plug-in connection technology MINI Analog Pro Bro IE Mini Analog Pro Rev01.indd 1 26.02.14 15:30 Easier than ever but slim as before MINI Analog Pro The highly compact MINI Analog Pro signal conditioners offer the easiest installation and startup in a confined space. Selectable connection technology Wiring with screw connection or fast and tool-free push-in technology. Easy maintenance Large-surface marking areas for complete loop identification using standard marking material. Easy installation Easily visible and accessible terminal points and FASTCON Pro plug-in connection terminal blocks. Consistent diagnostics Consistently visible status LEDs in each signal conditioner. Rapid power bridging and error messages Easily connect devices via the modular DIN rail connector. 2 Measure current signals easily Measure current signals during operation without disconnecting the current loop. PHOENIX CONTACT Bro IE Mini Analog Pro Rev01.indd 2 26.02.14 15:32 Bro MINI Analog Pro product overview Analog IN/ Analog OUT 2-wire 3-wire Signal conditioners • Universal signal conditioners • Standard signal conditioners • Repeater power supplies Page 8 4-wire Easy startup and service Interrupt signal and supply circuits with just a twist thanks to the integrated disconnect function. Temperature Temperature transducers • Universal temperature transducers for resistance thermometers and thermocouples Page 9 Potentiometers Potentiometer measuring transducers • Potentiometer measuring transducers with automatic potentiometer detection Numerous parameterization options Easy configuration via DIP switches as well as extended configuration via software or smartphone app without additional accessories. Page 9 Accessories + 70 °C • Supply components • Fault monitoring module • Marking material - 40 °C Page 9 Optimum signal quality The latest switching technology with multi-functional device types, safe electrical isolation, and extended supply voltage and operating temperature range. Universal use thanks to the international approval package PHOENIX CONTACT 15:32 Bro IE Mini Analog Pro Rev01.indd 3 3 26.02.14 15:32 The easiest installation and startup in a confined space Installation and startup of MINI Analog Pro is incredibly easy: Now it's within your reach Thanks to the design, all connections and operating elements are clearly visible and easily accessible. This not only saves space above and below the device, it saves time during installation. Insert the wires in any order, even in a confined space. Everything at a glance Large-surface marking areas for standard marking material permit complete loop identification despite the compact design. Status and error indicators are always visible and provide you with an instant on-site overview. Unique in the 6 mm class MINI Analog Pro is the first 6 mm range with plug-in connection technology. The FASTCON Pro connection terminal blocks can even be independently inserted and removed from the device system. Interrupt signal and supply circuits easily during service and startup with the disconnect function. Measure current signals without disconnection Measure current signals without disconnecting the signal circuit. With just a single measurement, you can record the entire current loop from the sensor to the controller. 4 PHOENIX CONTACT Bro IE Mini Analog Pro Rev01.indd 4 26.02.14 15:32 Bro Numerous parameterization options Many of the MINI Analog Pro signal conditioner device types can be configured for optimal adaptation to your application. Choose from a wide range of configuration types: Easy DIP switch configuration You can easily set the standard functions via the DIP switches on the device - without using any software. Here, the calibrated measuring range switchover guarantees a consistent level of accuracy without additional adjustment. DIP switches on the housing side PC configuration for extended function and monitoring For extended functionality and monitoring, you can also configure the multi-function modules conveniently via PC using one of the free software solutions available for download: • ANALOG-CONF standalone software • FDT/DTM software package • Standalone DTMs, allowing you to use your existing FDT frame application Smart configuration without additional accessories ANALOG-CONF standalone software Place your smartphone on the device and establish a wireless connection via Near Field Communication (NFC). Depending on the device type, the free MINI Analog Pro app offers a wide range of functions: NFC Module information • Call up module information NFC DIP switch setting aid • Call up module information • DIP switch setting aid NFC Configuration • Call up module information • DIP switch setting aid • Module configuration Install the MINI Analog Pro app now, in no time at all! Order configuration Order your devices easily and flexibly with the required configuration ex works: • Using order keys from the catalog or • In the user-guided e-shop: phoenixcontact.com PHOENIX CONTACT 15:32 Bro IE Mini Analog Pro Rev01.indd 5 5 26.02.14 15:33 Optimum signal quality State-of-the-art switching technology High-quality contacts The connection terminal blocks make contact by means of robust direct insertion. There are no metal pins that can be damaged. Maximum electrical isolation Flexible supply The latest transmission technology and safe electrical isolation between the input, output, and supply with a 3 kV test voltage: MINI Analog Pro offers you unrivalled isolation quality in the 6 mm class. The extended supply voltage range from 9.6 to 30 V DC ensures high availability and enables flexible use, for example in 12 V applications. Hot, cold? No problem! Quality from a single source – Made in Germany The wide operating temperature range from - 40 °C to + 70 °C enables use even under extreme ambient conditions. It is only when you keep sight of every little detail that you can be sure of the quality. This is why we develop and produce everything ourselves for MINI Analog Pro. We produce high-quality “Made in Germany” signal conditioners at our own plastic, metal, and SMD production facilities. Another advantage for you: short delivery times, even for high quantities. + 70 °C - 40 °C MINI Analog Pro signal conditioners are safe and reliable even at - 40 °C 6 Modern production processes ensure high quality and short delivery times PHOENIX CONTACT Bro IE Mini Analog Pro Rev01.indd 6 26.02.14 15:33 Bro Flexible and simple power supply MINI Analog Pro signal conditioners offer a flexible system solution for supplying devices. The supply voltage is bridged by the modular DIN rail connector. This simplifies wiring, system expansion or module replacement, even during operation. Power IN 2 Power IN 1 Power module The DIN rail connector gives you three device supply options: Power IN 1. Direct DC supply at any MINI Analog Pro module: • For up to 16 MINI Analog Pro modules • No additional accessories required other than the DIN rail connector 2. Via a power module of the same shape • For up to 115 MINI Analog Pro modules • Also allows redundant supply and supply monitoring Power IN 2 3. Via the system power supply with 85 to 264 V AC wide-range input: • When a DC supply is not available • For up to 60 MINI Analog Pro modules Power supply Power IN Power IN 3 Convenient error evaluation with fault monitoring Fault monitoring is a modular solution for convenient error evaluation in multi-channel applications. Depending on the module type, the following errors can be indicated by means of a group error message: • • • • • Measuring range overshot Measuring range undershot Open circuit Short circuit Module error It is also possible to detect and indicate the failure of a supply voltage at the power terminal block. The modularity is characterized by the ability to freely adjust the error evaluation, both on the device side and in the evaluation module. Error message contact Fault monitoring module Power IN Power module Power IN Group error message for up to 115 devices Supply voltage monitoring PHOENIX CONTACT 15:33 Bro IE Mini Analog Pro Rev01.indd 7 7 26.02.14 15:35 MINI Analog Pro product overview Analog IN / Analog OUT Analog IN / Analog OUT Analog IN / Analog OUT U,I IN U,I NFC OUT IN U,I U,I NFC OUT IN U,I FM POWER FM POWER Universal 4-way signal conditioner with relay contact, configurable U,I OUT NFC FM POWER 3-way signal conditioner, configurable 3-way signal conditioner, with fixed signal combinations IN 0 … 24 mA (freely adjustable, min. 1 mA interval) 0 … 12 V (freely adjustable, min. 0.5 V interval) Can be set via DIP switch, software or app 0 … 20 mA, 4...20 mA, -20...20 mA, 0 … 5 V, 1 … 5 V, -5 … 5 V, 0 … 10 V, 2 … 10 V, -10 … 10 V, 0 … 20 V, 4 … 20 V, -20 … 20 V, 0 … 24 V, 4.8 … 24 V, -24 … 24 V, 0 … 30 V, 6 … 30 V, -30 … 30 V Can be set via DIP switch 1) 0 … 20 mA, 4 … 20 mA; IN = OUT 2) 0 … 10 V, -10 … 10 V; IN = OUT OUT 0 … 21 mA (freely adjustable, min. 1 mA interval) 0 … 10.5 V (freely adjustable, min. 0.5 V interval) With fault signaling Supports fault monitoring Can be set via DIP switch, software or app 0 … 20 mA, 4 … 20 mA, 0 … 5 V, 1 … 5 V, -5 … 5 V, 0 … 10 V, 2 … 10 V, -10 … 10V Supports fault monitoring Can be set via DIP switch 1) 0 … 20 mA, 4 … 20 mA; IN = OUT 2) 0 … 10 V, -10 … 10 V; IN = OUT Supports fault monitoring Screw connection MINI MCR-2-UNI-UI-UIRO *) 2902026 MINI MCR-2-UI-UI *) 2902037 1) MINI MCR-2-I-I 2901998 2) MINI MCR-2-U-U 2902042 Push-in connection MINI MCR-2-UI-UI-PT *) 2902040 MINI MCR-2-UNI-UI-UIRO-PT *) 2902028 1) MINI MCR-2-I-I-PT 2901999 2) MINI MCR-2-U-U-PT 2902043 Analog IN / Analog OUT U IN I NFC OUT Analog IN / Analog OUT IN U I Analog IN / Analog OUT NFC OUT POWER I I OUT NFC IN FM POWER FM POWER FM POWER 3-way signal conditioner, with fixed signal combinations 3-way signal conditioner, with fixed signal combinations Repeater power supply, HART-transparent IN 1) 0 … 10 V 2) 0 … 10 V 1) 0 … 20 mA 2) 4 … 20 mA Isolator operation: 0 … 20 mA, 4 … 20 mA; IN = OUT Repeater power supply 4 … 20 mA; IN = OUT OUT 1) 0 … 20 mA 2) 4 … 20 mA Supports fault monitoring 1) 0 … 10 V 2) 0 … 10 V Supports fault monitoring 0 … 20 mA, 4 … 20 mA; IN = OUT Supports fault monitoring Screw connection Push-in connection 1) MINI MCR-2-I0-U 2902000 2) MINI MCR-2-U-I4 2902029 2) MINI MCR-2-I4-U 2902002 1) MINI MCR-2-U-I0-PT 2902023 1) MINI MCR-2-I0-U-PT 2902001 2) MINI MCR-2-U-I4-PT 2902030 2) MINI MCR-2-I4-U-PT 2902003 *) 8 PHOENIX CONTACT Bro IE Mini Analog Pro Rev01.indd 8 MINI MCR-2-RPSS-I-I 2902014 1) MINI MCR-2-U-I0 2902022 Versions can also be ordered pre-configured ex-works T-Connector Compatible MINI MCR-2-RPSS-I-I-PT 2902015 The module can be snapped onto the DIN rail connector. 26.02.14 15:36 Bro MINI Analog Pro product overview Temperature U,I IN Temperature NFC OUT IN U,I FM POWER OUT Potentiometer NFC U,I OUT NFC FM POWER FM POWER Universal measuring transducer for resistance thermometers, configurable Universal measuring transducer for thermocouples, configurable Potentiometer measuring transducer, configurable IN 2, 3 or 4-wire IEC 751: Pt100, Pt200, Pt500, Pt1000 GOST 6651-2009: Pt100, Pt1000, Cu50, Cu100, Cu53 JIS C1604-1997: Pt100, Pt1000 DIN 43760: Ni100, Ni1000 -200°C … 850°C (sensor-dependent) Linear resistance: 0 … 4 kΩ Can be set via DIP switch, software or app IEC 584-1: B, E, J, K, N, R, S, T DIN 43710: L, U GOST 8.585: A-1, A-2, A-3, M, L -250°C … 2500°C (sensor-dependent) Can be set via DIP switch, software or app 3-wire potentiometer 100 ohms … 100 kΩ Automatic detection Can be set via DIP switch, software or app OUT 0 … 21 mA (freely adjustable, min. 1 mA interval) 0 … 10.5 V (freely adjustable, min. 0.5 V interval) With fault signaling Supports fault monitoring Can be set via DIP switch, software or app 0 … 21 mA (freely adjustable, min. 1 mA interval) 0 … 10.5 V (freely adjustable, min. 0.5 V interval) With fault signaling Supports fault monitoring Can be set via DIP switch, software or app 0 … 21 mA (freely adjustable, min. 1 mA interval) 0 … 10.5 V (freely adjustable, min. 0.5 V interval) With fault signaling Supports fault monitoring Can be set via DIP switch, software or app Screw connection MINI MCR-2-RTD-UI *) 2902049 MINI MCR-2-TC-UI *) 2902055 MINI MCR-2-POT-UI *) 2902016 Push-in connection MINI MCR-2-RTD-UI-PT *) 2902052 MINI MCR-2-TC-UI-PT *) 2905249 MINI MCR-2-POT-UI-PT *) 2902017 Accessories Accessories Accessories IN POWER POWER IN NFC IN PTB POWER MONITORING POWER OUT NFC OUT FM Description For redundant supply on the DIN rail connector Inputs: 9.9 … 30 V DC Output: max. 3.2 A; 9.6 … 29.7 V DC Monitoring of the supply possible in combination with fault monitoring Fault monitoring module for evaluating and reporting group errors from the fault monitoring system Monitoring of supply voltages of MINI MCR-2-PTB(-PT) power terminal blocks Feed-through terminal block for 1:1 forwarding of signals that are already electrically isolated in the MINI Analog Pro group MINI MCR-2-TB 2902068 MINI MCR-2-FM-RC 2904504 Push-in connection MINI MCR-2-PTB-PT 2902067 MINI MCR-2-FM-RC-PT 2904508 Bro IE Mini Analog Pro Rev01.indd 9 NFC Feed-through terminal block 1:1 connection MINI MCR-2-PTB 2902066 DIP switch setting aid NFC • Call up module information • DIP switch setting aid OUT Fault monitoring module Screw connection Module information NFC • Call up module information 1:1 IN OUT Power terminal block IN FM POWER POWER 15:36 R IN NFC Configuration • Call up module information • DIP switch setting aid • Module configuration PHOENIX CONTACT 9 26.02.14 15:36 Accessories for MINI Analog Pro DIN rail connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GY Order No. 2695439 • Gray, for two MINI Analog Pro modules each ME 17,5 TBUS 1,5/5-ST-3,81 GN Order No. 2709561 • Green, for MINI-SYS system power supply (2 required) System power supply MINI-SYS-PS-100-240AC/24DC/1.5 Order No. 2866983 MINI-PS-100-240AC/24DC/1.5/EX Order No. 2866653 (Ex n-capable) • Wide range input: 85 … 264 V AC (45 – 65 Hz) • Output voltage: 24 V DC ±1% • Output current: 1.5 A at 60°C/2 A at 40°C Programming adapter IFS-USB-PROG-ADAPTER Order No. 2811271 • Programming adapter with USB interface, for programming via PC. NFC-USB-PROG-ADAPTER Order No. 2900013 • Programming adapter with NFC interface, for wireless programming via PC. Flexible printing Easily generate your own marking: we have the right printing system for your requirements. Marking labels UCT-EM (30x5) Order No. 0801505 UCT-EM (30x5) CUS Order No. 0801589 UCT-EM (30x5) YE Order No. 0830340 UC-EMLP (15x5) Order No. 0819301 UC-EMLP (15x5) CUS Order No. 0824550 • For snapping or sticking onto module cover • Can be marked with THERMOMARK CARD or BLUEMARK printer • Lettering field size: 30 x 5 mm/15 x 5 mm 10 PHOENIX CONTACT Bro IE Mini Analog Pro Rev01.indd 10 Adhesive labels SK 5,0 WH:REEL Order No. 0805221 • Self-adhesive marker strips, unprinted, continuous • Roll material for marking with THERMOMARK ROLL thermal transfer printer You can find other marking materials, printers, and printing accessories on our website: phoenixcontact.com 26.02.14 15:36 Bro Isolating, converting, filtering, and amplifying – the functions at a glance Electrical isolation The most important task of a signal conditioner is the electrical isolation of signals. MINI Analog Pro offers consistent isolation of input, output, and supply. As such, ground current loops can be prevented in the event of potential differences, which would otherwise lead to a distortion of the measured process values. I1 = 20 mA I2 = 18 mA Ig = 2 mA Ground current loop Sensor 2,000 mA Potential 2 Potential 1 I1 = 20 mA I2 = 20 mA Ig = 0 mA No ground current loop Sensor 0.000 mA Potential 1 Potential 2 Converting signals An advantage of signal conversion is the conversion of sensor signals into a signal that can be read by the controller. In addition, signals susceptible to interference can be converted into less sensitive signals. 4 – 20 mA 0 – 10 V Sensor Amplifying signals Signals always need to be amplified when cables are long or if high loads need to be driven. It is here where the signal conditioners of the MINI Analog Pro range provide a high output power at a low input power. Can only drive loads of up to 300 Ω Can amplify loads up to 600 Ω 4 – 20 mA 4 – 20 mA + 24 V DC Sensor Filtering signals U In industrial environments, interference often occurs as a result of high-frequency signals. The input filters of the MINI Analog Pro signal conditioners therefore reliably filter out such interference signals. U t 0 – 10 V t 0 – 10 V Sensor PHOENIX CONTACT 15:36 Bro IE Mini Analog Pro Rev01.indd 11 11 26.02.14 15:36 Always up-to-date, always available to you. Here you'll find everything on our products, solutions and service: phoenixcontact.net Product range • Industrial communication technology • Industrial Ethernet • Installation and mounting material • Lighting and signaling • Marking and labeling • Measurement and control technology • Modular terminal blocks • Monitoring • PCB terminal blocks and PCB connectors • Power supply units and UPS • Protective devices • Relay modules • Sensor/actuator cabling • Software • Surge protection and interference filters • System cabling for controllers • Tools • Wireless data communication PHOENIX CONTACT GmbH & Co. KG 32825 Blomberg, Germany Phone: +49 (0) 52 35 3-00 Fax: +49 (0) 52 35 3-4 12 00 phoenixcontact.net Bro IE Mini Analog Pro Rev01.indd 12 IF 04-13.000.L3.2013 MNR 52005212/2014-02-01/01 Printed in Germany © PHOENIX CONTACT 2014 • Cables and wires • Connectors • Controllers • Electronics housing • Electronic switchgear and motor control • Fieldbus components and systems • Functional safety • HMIs and industrial PCs • I/O systems 26.02.14 15:36