Bel Stewart Connector

Bel Stewart Connector
36 SERIES SHIELDED PLUG W/-A108 LOAD BAR
ASSEMBLY INSTRUCTIONS
11118 Susquehanna Trail South Glen Rock, PA 17327
36 SERIES SHIELDED PLUG WITH –A108 LOAD BAR ASSEMBLY INSTRUCTIONS
Assembly steps 1 – 11:
1
Slide strain relief over cable
2
3
Trim off 1” to 2” of cable jacket
Fold back shield and drain wire
78
12
4
Slide ferrule over jacket and shield.
Do no trap any insulation between
shield and ferrule
Crimp ferrule. Position pairs 12
and 78 to the outside
7
Untwist and straighten pairs
Page 1 of 2
6
5
8
Align pairs (568-B shown)
Remove excess shield. Remove
plastic foil insulation if present
9
Place wires into –A108 load bar.
Trim wires flush with end of load
bar
MN360015-A0
Bel Stewart Connector
36 SERIES SHIELDED PLUG W/-A108 LOAD BAR
ASSEMBLY INSTRUCTIONS
11118 Susquehanna Trail South Glen Rock, PA 17327
36 SERIES SHIELDED PLUG WITH –A108 LOAD BAR ASSEMBLY INSTRUCTIONS
Assembly steps 1 – 11 (Cont.):
10
Insert load bar and wires into
plug housing
11
Verify wire ends are visible
through plug housing
12
Terminate housing onto cable
13
Slide strain relief over housing.
Assembly is now complete
Page 2 of 2
MN360015-A0