3 Phase RHP - Hybrid Solid State Contactors 3 Phase Contactor 3 Phase Contactor 40-50 Amp 280/600 VAC 40-50 Amp 120/240 VAC DC Input ENT PATDING PEN AC Input Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required DC logic compatible input Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized 100k-cycle UL508 endurance rating Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized 100k-cycle UL508 endurance rating CONTROL SPECIFICATIONS 1 E F 20 - 26 VAC, 50/60 Hz 20 VAC 12 VAC 56 VA @ 24 VAC 6.6 VA @ 24 VAC 10 in lb (1.13 Nm) OUTPUT SPECIFICATIONS OUTPUT SPECIFICATIONS 3 2 Screw torque requirements GENERAL SPECIFICATIONS 40 50 40 A Resistive Dual quick connect and Binder head screws / AWG#14 - AWG#8 18 in lbs (2.1 Nm) 50 A Resistive Dual quick connect and Box lugs / AWG#14 - AWG#6 25 in lbs (2.9 Nm) GENERAL SPECIFICATIONS Ambient Storage Temperature Range Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute 2 3 4 -40°C to 100°C Ambient Storage Temperature Range Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute 540 grs (1.19 lb) 3 RHP Three Phase Device 1 2 3 4 12 4 -20°C to 75°C -40°C to 100°C 16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz 30 operations per min > 2 Million operations 540 grs (1.19 lb) Specificationts @ 25°C unless otherwise noted. See Derating Curves for additional operational conditions. The RHP includes a Solid-State Relay. Therefore, the output is never completely open. The RHP includes an overtemperature protection for the Solid-State Module. Derating Curves Load Current 40: 40 Amps 50: 50 Amps SERIES 4000 VAC 2500 VAC Lifetime @ Rated Load Current, 40°C ambient temp, 30 operations/min, Rated Vcontrol Weight (typical) Specificationts @ 25°C unless otherwise noted. See Derating Curves for additional operational conditions. The RHP includes a Solid-State Relay. Therefore, the output is never completely open. The RHP includes an overtemperature protection for the Solid-State Module. Part Number Nomenclature 40 A Resistive 50 A Resistive Dual quick connect and Binder Dual quick connect and Box head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6 18 in lbs (2.1 Nm) 25 in lbs (2.9 Nm) Three Normally Open Ambient Operating Temperature Range 55 40 D5 Operating Voltage VAC 50/60 Hz 3RHPXX50XX 3RHPXX40XX Nominal Coil /Control Voltage 12: 120 V 1-phase 24: 240 V 3-phase or 1-phase D5: 5 VDC D12: 12 VDC D24: 24 VDC 28: 280 V 3-phase 60: 600 V 3-phase E: 24 VAC F: 120 VAC G: 220 VAC Load Current, Amps rms 1 50 40 2 Contacts (Double Break) 3 > 2 Million operations Lifetime @ Rated Load Current, 40°C ambient temp, 30 operations/min, Rated Vcontrol Weight (typical) 3 208 - 240 VAC 0.06 mA @ 240 VAC 1 -20°C to 75°C 16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz 30 operations per min 24 12 100 - 120 VAC 0.05 mA @ 120 VAC Input to Output Dielectric Isolation Input/Output to Ground Dielectric Isolation Three Normally Open 4 D24 22 - 27 VDC -27.5 VDC 9.5 VDC 2 VDC 12mA @ 24 VDC 5.31 in lb (0.6 Nm) Screw torque requirements 4000 VAC 2500 VAC 3 Ambient Operating Temperature Range D12 10 - 15 VDC -15.5 VDC 9.5 VDC 2 VDC 12mA @ 12 VDC 5.31 in lb (0.6 Nm) 1 Load Current suffix Maximum Load Current per Phase @ 40°C Power terminals / wire range 1 Input to Output Dielectric Isolation. Input/Output to Ground Dielectric Isolation. D5 4.5 - 5.5 VDC -5.5 VDC 4.5 VDC 1 VDC 12mA @ 5 VDC 5.31 in lb (0.6 Nm) Voltage suffix Operating Voltage (50/60Hz) Maximum Off-State Leakage Current per channel 48 - 600 VAC 0.06 mA @ 480 VAC 24 - 280 VAC 0.05 mA @ 240 VAC Load Current suffix Maximum Load Current per Phase @ 40°C Power terminals / wire range 60 28 1 Control Voltage Suffix Control Voltage Range Max. Reverse Voltage Min. Turn-On Voltage Min. Turn-Off Voltage Input Current Input Connector 100 - 130 VAC, 50/60 Hz 208 - 240 VAC, 50/60 Hz 100 VAC 208 VAC 24 VAC 48 VAC 56 VA @ 120 VAC 56 VA @ 220 VAC 6.6 VA @ 120 VAC 6.6 VA @ 220 VAC 10 in lb (1.13 Nm) 10 in lb (1.13 Nm) 1 Voltage suffix Operating Voltage (50/60Hz) Maximum Off-State Leakage Current per channel Contacts (Double Break ) CONTROL SPECIFICATIONS G 45 Load Current, Amps rms Control Voltage Suffix Coil Voltage Range Min. Turn-On Voltage Min. Turn-Off Voltage Coil Power Consumption, Inrush Coil Power Consumption, Sealed Coil Terminals ENT PATDING PEN 40 35 Power lead size AWG # 6 AWG # 8 30 Safe Operating Area 50 45 Power lead size AWG # 6 AWG # 8 40 35 30 Safe Operating Area 25 25 20 20 25 35 45 55 65 Ambient Temperature, °C 75 25 35 45 55 65 Ambient Temperature, °C 75 3 Phase RHP - Hybrid Solid State Contactors 5 AC Input/Control Voltage (E, F, G input versions) VLL 1L1 3Ø Load 4T2 5L3 3L2 1L1 I L1 I L1 IL1 = (IL2 + IL3) ≤ Rated current AC Input/Control Voltage (E, F, G input versions) DO NOT apply any AC voltage to contactor coil connections, for DC versions only. Line Optional Electrical Connections for Single Phase Applications 6 (For output voltage options 12, 24, 28, 60) 120/240 VAC Single Phase Operating Voltage 3L2 1L1 6T3=NC - + ~ Line HYBRID SOLID STATE CONTACTOR AC Input/Control Voltage (E, F, G input versions) 120/240 VAC Single Phase Operating Voltage R2 R1 DC Input/Control Voltage (D5, D12, D24 input versions) DC Input/Control Voltage (D5, D12, D24 input versions) 5L3=NC I L2 Neutral 2T1 I L1 I L3 Neutral I L1 Neutral 5 6 7 IL1 ≤ Rated current 3L2 1L1 I L3 I L2 R2 NC R1 7 DC Input/Control Voltage (D5, D12, D24 input versions) IL2 ≤ Rated current IL3 ≤ Rated current IL2 + IL3 > Rated current R1 DC Input/Control Voltage (D5, D12, D24 input versions) ~ 5L3 - + 3L2 120/240 VAC Single Phase Operating Voltage 6T3 - + HYBRID SOLID STATE CONTACTOR ~~ ~ I L3 5L3 ~ Line HYBRID SOLID STATE CONTACTOR AC Input/Control Voltage (E, F, G input versions) 3 Phase AC Operating Voltage - + (For output voltage options 24, 28, 60) HYBRID SOLID STATE CONTACTOR Typical Electrical Connection for 3 Phase Applications Match VLL to voltage suffixes 28 & 60 for options E, F & G and 12 & 24 for options DX. The single phase supply voltage must be wired to terminal 1L1 and 3L2 for proper single phase operation. In applications switching two single phase loads (R1 and R2) where the combined load current exceeds the contactor’s rating (40 or 50 Amps) the return/neutral lead must not be wired through the contactor (see above drawing).